ConductScience.org, home

Comparison · NCT00114972-c11826ac

CABG vs PCI With DES: 12-month Composite Safety Endpoint.

Calculated by ConductScience from the counts the trial posted to ClinicalTrials.gov.

2 sourcestrial-comparisons-2026-03-23-0.1.0

Download JSON
Cite this record

ConductScience Library. CABG vs PCI With DES: 12-month Composite Safety Endpoint. Trial comparisons, record NCT00114972-c11826ac. Release trial-comparisons-2026-03-23-0.1.0, 23 Mar 2026. https://conductscience.org/library/comparisons/NCT00114972-c11826ac

On this page

Measures6

Calculated by ConductScience from the counts the trial posted to ClinicalTrials.gov.

MeasureValue95% interval, lower95% interval, upperMethodNote
Risk in group 10.07660.06050.0964wilson
Risk in group 20.07630.06060.0956wilson
Risk difference, group 1 minus group 20.000242-0.02490.0255newcombe hybrid score
Risk ratio, group 1 over group 210.7241.39log
Odds ratio, group 1 over group 210.7041.43log
Number needed to treat, for one more participant with the outcome on CABG than on PCI With DES4,130from the risk difference intervalthe interval includes no difference

Groups2

Neither group, or both, names a comparator, so the groups keep ClinicalTrials.gov's order.

GroupTitleDescriptionWith the outcomeAnalysedClinicalTrials.gov code
Group 1CABGCoronary Artery By-pass Graft (CABG)65849OG000
Group 2PCI With DESPercutaneous coronary intervention (PCI) using TAXUS Express Drug Eluting Stent (DES)68891OG001

Outcome

Type
PRIMARY
Title
12-month Composite Safety Endpoint.
Description
Number of participants at 12-month composite safety endpoint. Composite safety endpoint combines: all cause death, cerebrovascular event (stroke), and documented myocardial infarction.
Time frame
12 months after enrollment
Population

Source ClinicalTrials.gov

Trial

Title
SYNTAX Study: TAXUS Drug-Eluting Stent Versus Coronary Artery Bypass Surgery for the Treatment of Narrowed Arteries
NCT number
NCT00114972
Phases
PHASE3
Conditions
Coronary Artery Disease
Interventions
Polymer-based Paclitaxel-Eluting TAXUS Express2-SR Stent, Coronary Artery Bypass Surgery
Lead sponsor
Boston Scientific Corporation
Results first posted
2010-06-23

Source ClinicalTrials.gov

Source

Release
trial-comparisons-2026-03-23-0.1.0
Release manifest SHA-256
f66225897fbf258b57ea10bdacfd0347d3cdfda93f7f5685234b7e06ea36fa57
AACT copy
2026-03-23
Tables read
outcome_counts.parquet, outcome_measurements.parquet, outcomes.parquet, reported_event_totals.parquet, reported_events.parquet, result_groups.parquet, studies.parquet, ctgov_trial.parquet

Source ClinicalTrials.gov

Sources 2

  • ClinicalTrials.gov's posted results, through CTTI's AACTFreely available. Acknowledgement requested
  • ClinicalTrials.govNo license stated
Each source's terms
  • ClinicalTrials.gov's posted results, through CTTI's AACTClinicalTrials.gov data via Aggregate Analysis of ClinicalTrials.gov (AACT), CTTI. CTTI makes its materials freely available and requests acknowledgement. https://aact.ctti-clinicaltrials.org/documentation/299
  • ClinicalTrials.govnone stated

ClinicalTrials.gov's data carry an international copyright outside the United States: https://clinicaltrials.gov/about-site/terms-conditions. The measures are ConductScience's calculation from them.

For software