Absorb BVS vs XIENCE: Number of Participants With Target Lesion Failure (TLF)

Calculated by ConductScience from the counts the trial posted to ClinicalTrials.gov.

2 sourcestrial-comparisons-2026-03-23-0.1.0

Download JSON
Cite this record

ConductScience Library. Absorb BVS vs XIENCE: Number of Participants With Target Lesion Failure (TLF). Trial comparisons, record NCT02173379-a49855f8. Release trial-comparisons-2026-03-23-0.1.0, 23 Mar 2026. https://conductscience.org/library/comparisons/NCT02173379-a49855f8

On this page

Measures6

Calculated by ConductScience from the counts the trial posted to ClinicalTrials.gov.

MeasureValue95% interval, lower95% interval, upperMethodNote
Risk in group 10.07810.06450.0943wilson
Risk in group 20.06520.05290.0801wilson
Risk difference, group 1 minus group 20.0129-0.007290.0332newcombe hybrid score
Risk ratio, group 1 over group 21.20.9041.59log
Odds ratio, group 1 over group 21.210.8971.64log
Number needed to treat, for one more participant with the outcome on Absorb BVS than on XIENCE77.6from the risk difference intervalthe interval includes no difference

Groups2

Neither group, or both, names a comparator, so the groups keep ClinicalTrials.gov's order.

GroupTitleDescriptionWith the outcomeAnalysedClinicalTrials.gov code
Group 1Absorb BVS
Subjects receiving Absorb Bioresorbable Vascular Scaffold (BVS) System, and the Absorb GT1™ BVS System~Absorb BVS: -Scaffold diameters: 2.5, 3.0 and 3.5 mm~* Scaffold lengths: 8, 12, 18, and 28 mm. Both the 8 mm and 12 mm lengths will be available for the 2.5/3.0 mm diameter Absorb BVS. Only the 12 mm length will be available for the 3.5 mm diameter.~* Once Absorb GT1™ BVS System is commercially available, it can also be used in the ABSORB IV trial. Scaffold diameters: 2.5, 3.0 and 3.5 mm of and scaffold lengths: 8, 12, 18, 23, and 28 mm.~* The commercially approved CE marked device will be used in geographies where it is commercially available. The commercially approved CE marked 23mm Absorb BVS device will not be used in this study.~Bioabsorbable drug eluting stent implantation for improving coronary luminal diameter in patients, including those with diabetes mellitus, with ischemic heart disease due to de novo native coronary artery lesions (length ≤ 24 mm) with a reference vessel diameter of ≥ 2.5 mm and ≤ 3.75 mm.
981,255OG000
Group 2XIENCE
Subjects receiving XIENCE V, XIENCE PRIME, or XIENCE Xpedition, XIENCE Alpine, XIENCE Pro (outside of the US only) and XIENCE ProX (outside of the US only)~XIENCE: Commercially approved XIENCE Family Stent System, inclusive of XIENCE V, XIENCE PRIME, XIENCE Xpedition, XIENCE Alpine, XIENCE Pro (OUS only), and XIENCE ProX (OUS only).~* Stent diameters: 2.5, 2.75, 3.0, 3.25, 3.5 and 4.0 mm. The 3.25 mm is only available for XIENCE Xpedition~* Stent lengths: 8, 12, 15, 18, 23, and 28 mm~* For geographies where these devices are commercially available, the investigational sties may use only their locally approved devices~To improve coronary luminal diameter in patients, including those with diabetes mellitus, with ischemic heart disease due to de novo native coronary artery lesions (length ≤ 24 mm) with a reference vessel diameter of ≥ 2.5 mm and ≤ 3.75 mm.
831,273OG001

Outcome

Type
SECONDARY
Title
Number of Participants With Target Lesion Failure (TLF)
Description
The analysis will be based on 4610 subjects (2000 primary analysis subjects of ABSORB III and 2610 subjects of ABSORB IV)
Time frame
1 year
Population
ITT population. The number of participants analyzed includes subjects who had available follow up data at that time frame.

Source ClinicalTrials.gov

Trial

Title
Absorb IV Randomized Controlled Trial
NCT number
NCT02173379
Phases
NA
Conditions
Coronary Artery Disease, Coronary Artery Stenosis, Coronary Disease, Coronary Stenosis
Interventions
Absorb BVS, XIENCE
Lead sponsor
Abbott Medical Devices
Results first posted
2018-07-24

Source ClinicalTrials.gov

Source

Release
trial-comparisons-2026-03-23-0.1.0
Release manifest SHA-256
f66225897fbf258b57ea10bdacfd0347d3cdfda93f7f5685234b7e06ea36fa57
AACT copy
2026-03-23
Tables read
outcome_counts.parquet, outcome_measurements.parquet, outcomes.parquet, reported_event_totals.parquet, reported_events.parquet, result_groups.parquet, studies.parquet, ctgov_trial.parquet

Source ClinicalTrials.gov

Sources 2

  • ClinicalTrials.gov's posted results, through CTTI's AACTFreely available. Acknowledgement requested
  • ClinicalTrials.govNo license stated
Each source's terms
  • ClinicalTrials.gov's posted results, through CTTI's AACTClinicalTrials.gov data via Aggregate Analysis of ClinicalTrials.gov (AACT), CTTI. CTTI makes its materials freely available and requests acknowledgement. https://aact.ctti-clinicaltrials.org/documentation/299
  • ClinicalTrials.govnone stated

ClinicalTrials.gov's data carry an international copyright outside the United States: https://clinicaltrials.gov/about-site/terms-conditions. The measures are ConductScience's calculation from them.

For software

Read this comparison from software.

The record is JSON. No key.

GET https://conductscience.org/api/comparisons/v1/NCT02173379-a49855f8