ConductScience.org, home

Comparison · NCT02879448-deaths

Amulet vs WATCHMAN (Control): deaths from any cause

Calculated by ConductScience from the counts the trial posted to ClinicalTrials.gov.

2 sourcestrial-comparisons-2026-03-23-0.1.0

Download JSON
Cite this record

ConductScience Library. Amulet vs WATCHMAN (Control): deaths from any cause. Trial comparisons, record NCT02879448-deaths. Release trial-comparisons-2026-03-23-0.1.0, 23 Mar 2026. https://conductscience.org/library/comparisons/NCT02879448-deaths

On this page

Measures6

Calculated by ConductScience from the counts the trial posted to ClinicalTrials.gov.

MeasureValue95% interval, lower95% interval, upperMethodNote
Risk in group 10.2690.2410.298wilson
Risk in group 20.2790.2510.308wilson
Risk difference, group 1 minus group 2-0.00987-0.05010.0305newcombe hybrid score
Risk ratio, group 1 over group 20.9650.8321.12log
Odds ratio, group 1 over group 20.9520.7771.17log
Number needed to treat, for one fewer death from any cause on Amulet than on WATCHMAN (Control)101from the risk difference intervalthe interval includes no difference

Groups2

Neither group, or both, names a comparator, so the groups keep ClinicalTrials.gov's order.

GroupTitleDescriptionWith the outcomeAnalysedClinicalTrials.gov code
Group 1AmuletAmulet left atrial appendage occluder~Amulet Left Atrial Appendage Occluder: Transcatheter left atrial appendage closure251934EG000
Group 2WATCHMAN (Control)WATCHMAN left atrial appendage closure device~WATCHMAN Left Atrial Appendage Closure: Transcatheter left atrial appendage closure263944EG001

Harm

What it counts
Total, all-cause mortality
Time frame
5 years

Source ClinicalTrials.gov

Trial

Title
AMPLATZER™ Amulet™ LAA Occluder Trial
NCT number
NCT02879448
Phases
NA
Conditions
Stroke
Interventions
Amulet Left Atrial Appendage Occluder, WATCHMAN Left Atrial Appendage Closure
Lead sponsor
Abbott Medical Devices
Results first posted
2022-01-11

Source ClinicalTrials.gov

Source

Release
trial-comparisons-2026-03-23-0.1.0
Release manifest SHA-256
f66225897fbf258b57ea10bdacfd0347d3cdfda93f7f5685234b7e06ea36fa57
AACT copy
2026-03-23
Tables read
outcome_counts.parquet, outcome_measurements.parquet, outcomes.parquet, reported_event_totals.parquet, reported_events.parquet, result_groups.parquet, studies.parquet, ctgov_trial.parquet

Source ClinicalTrials.gov

Sources 2

  • ClinicalTrials.gov's posted results, through CTTI's AACTFreely available. Acknowledgement requested
  • ClinicalTrials.govNo license stated
Each source's terms
  • ClinicalTrials.gov's posted results, through CTTI's AACTClinicalTrials.gov data via Aggregate Analysis of ClinicalTrials.gov (AACT), CTTI. CTTI makes its materials freely available and requests acknowledgement. https://aact.ctti-clinicaltrials.org/documentation/299
  • ClinicalTrials.govnone stated

ClinicalTrials.gov's data carry an international copyright outside the United States: https://clinicaltrials.gov/about-site/terms-conditions. The measures are ConductScience's calculation from them.

For software

Read this comparison from software.

The record is JSON. No key.

GET https://conductscience.org/api/comparisons/v1/NCT02879448-deaths