ConductScience.org, home

Comparison · NCT04149535-deaths

TAVR With Sentinel vs TAVR Without Sentinel: deaths from any cause

Calculated by ConductScience from the counts the trial posted to ClinicalTrials.gov.

2 sourcestrial-comparisons-2026-03-23-0.1.0

Download JSON
Cite this record

ConductScience Library. TAVR With Sentinel vs TAVR Without Sentinel: deaths from any cause. Trial comparisons, record NCT04149535-deaths. Release trial-comparisons-2026-03-23-0.1.0, 23 Mar 2026. https://conductscience.org/library/comparisons/NCT04149535-deaths

On this page

Measures6

Calculated by ConductScience from the counts the trial posted to ClinicalTrials.gov.

MeasureValue95% interval, lower95% interval, upperMethodNote
Risk in group 10.007330.00410.0131wilson
Risk in group 20.004670.002260.00961wilson
Risk difference, group 1 minus group 20.00266-0.003240.00889newcombe hybrid score
Risk ratio, group 1 over group 21.570.614.04log
Odds ratio, group 1 over group 21.570.6084.07log
Number needed to harm, for one more death from any cause on TAVR With Sentinel than on TAVR Without Sentinel376from the risk difference intervalthe interval includes no difference

Groups2

Neither group, or both, names a comparator, so the groups keep ClinicalTrials.gov's order.

GroupTitleDescriptionWith the outcomeAnalysedClinicalTrials.gov code
Group 1TAVR With SentinelPatients assigned to this group will undergo TAVR with the Sentinel® Cerebral Protection System.~Sentinel® Cerebral Protection System: cerebral embolic protection system111,501EG000
Group 2TAVR Without SentinelPatients assigned to this group will undergo TAVR without the Sentinel® Cerebral Protection System.71,499EG001

Harm

What it counts
Total, all-cause mortality
Time frame
Events were reported to BSC from the time of enrollment through 72 hours or subject discharge (whichever comes first) for all patients. For patients with stroke within 72hrs/discharge, events were reported to BSC from the time of enrollment through 30+/-7 days post stroke. All-Cause Mortality includes all patients through 72 hours or subject discharge (whichever comes first), plus mortality through 30+/-7 days for patients that had stroke.

Source ClinicalTrials.gov

Trial

Title
PROTECTED TAVR: Stroke PROTECTion With SEntinel During Transcatheter Aortic Valve Replacement
NCT number
NCT04149535
Phases
NA
Conditions
Stroke
Interventions
Sentinel® Cerebral Protection System
Lead sponsor
Boston Scientific Corporation
Results first posted
2023-02-02

Source ClinicalTrials.gov

Source

Release
trial-comparisons-2026-03-23-0.1.0
Release manifest SHA-256
f66225897fbf258b57ea10bdacfd0347d3cdfda93f7f5685234b7e06ea36fa57
AACT copy
2026-03-23
Tables read
outcome_counts.parquet, outcome_measurements.parquet, outcomes.parquet, reported_event_totals.parquet, reported_events.parquet, result_groups.parquet, studies.parquet, ctgov_trial.parquet

Source ClinicalTrials.gov

Sources 2

  • ClinicalTrials.gov's posted results, through CTTI's AACTFreely available. Acknowledgement requested
  • ClinicalTrials.govNo license stated
Each source's terms
  • ClinicalTrials.gov's posted results, through CTTI's AACTClinicalTrials.gov data via Aggregate Analysis of ClinicalTrials.gov (AACT), CTTI. CTTI makes its materials freely available and requests acknowledgement. https://aact.ctti-clinicaltrials.org/documentation/299
  • ClinicalTrials.govnone stated

ClinicalTrials.gov's data carry an international copyright outside the United States: https://clinicaltrials.gov/about-site/terms-conditions. The measures are ConductScience's calculation from them.

For software

Read this comparison from software.

The record is JSON. No key.

GET https://conductscience.org/api/comparisons/v1/NCT04149535-deaths