Paper33712918
Multiplex detection of blood-borne pathogens on a self-driven microfluidic chip using loop-mediated isothermal amplification.
Xie C and 7 others. Anal Bioanal Chem, 2021. Cited by 27 papers, by iCite.
11 sourcespapers-2026-11-12-0.1.0
Cite this record
ConductScience Library. Multiplex detection of blood-borne pathogens on a self-driven microfluidic chip using loop-mediated isothermal amplification. Papers, record 33712918. Release papers-2026-11-12-0.1.0, 12 Nov 2026. https://conductscience.org/library/papers/33712918
Paper
PubMed's record of the paper, with iCite's citation figures. No abstract is shown.
- Title
- Multiplex detection of blood-borne pathogens on a self-driven microfluidic chip using loop-mediated isothermal amplification.
- PubMed
Topics9
NLM's MeSH indexing of the paper, its major topics first.
| MeSH term | Major |
|---|---|
| Blood-Borne Pathogens | Major topic |
| Lab-On-A-Chip Devices | Major topic |
| Molecular Diagnostic Techniques | Major topic |
| Nucleic Acid Amplification Techniques | Major topic |
| HIV | |
| Hepacivirus | |
| Hepatitis B virus | |
| Limit of Detection | |
| Microfluidic Analytical Techniques |
Source PubMed
Grants3
Each grant PubMed's record writes, matched to the NIH project NIH's grant and paper links name for this paper, and each of those links the record does not write.
| Grant, as the record writes it | Agency | Country | NIH project | Stated by |
|---|---|---|---|---|
| BK20180005 | Jiangsu Provincial Science Fund for Distinguished Young Scholars | PubMed | ||
| 81673390 | National Natural Science Foundation of China | PubMed | ||
| No. QNRC2016889 | Jiangsu Provincial Medical Youth Talent Program | PubMed |
Source PubMed
References38
The papers the reference list in PubMed's record names, those in our copy of PubMed, in the list's order.
| Order | PMID | Title | Journal | Year | In Papers | Source |
|---|---|---|---|---|---|---|
| 1 | 652005 | Type B hepatitis after transfusion with blood containing antibody to hepatitis B core antigen. | N Engl J Med | 1978 | https://conductscience.org/library/papers/652005 | PubMed |
| 2 | 19682345 | Infectivity of human immunodeficiency virus-1, hepatitis C virus, and hepatitis B virus and risk of transmission by transfusion. | Transfusion | 2009 | https://conductscience.org/library/papers/19682345 | PubMed |
| 3 | 30653226 | Prevalence of Hepatitis B Virus, Hepatitis C Virus, and HIV Infection Among Patients With Newly Diagnosed Cancer From Academic and Community Oncology Practices. | JAMA Oncol | 2019 | https://conductscience.org/library/papers/30653226 | PubMed |
| 4 | 15317889 | Detection of HIV-1 and HCV infections among antibody-negative blood donors by nucleic acid-amplification testing. | N Engl J Med | 2004 | https://conductscience.org/library/papers/15317889 | PubMed |
| 5 | 20345570 | Prevalence, incidence, and residual risk of human immunodeficiency virus and hepatitis C virus infections among United States blood donors since the introduction of nucleic acid testing. | Transfusion | 2010 | https://conductscience.org/library/papers/20345570 | PubMed |
| 6 | 19586663 | Identification of low HBV-DNA levels by nucleic acid amplification test (NAT) in blood donors. | J Infect | 2009 | https://conductscience.org/library/papers/19586663 | PubMed |
| 7 | 32109949 | Performance evaluation of a laboratory developed PCR test for quantitation of HIV-2 viral RNA. | PLoS One | 2020 | https://conductscience.org/library/papers/32109949 | PubMed |
| 8 | 31254912 | The new Xpert HCV viral load real-time PCR assay accurately quantifies hepatitis C virus RNA in serum and whole-blood specimens. | J Clin Virol | 2019 | https://conductscience.org/library/papers/31254912 | PubMed |
| 9 | 21387067 | Miniaturized isothermal nucleic acid amplification, a review. | Lab Chip | 2011 | https://conductscience.org/library/papers/21387067 | PubMed |
| 10 | 31519395 | Loop-mediated isothermal amplification (LAMP): Expansion of its practical application as a tool to achieve universal health coverage. | J Infect Chemother | 2020 | https://conductscience.org/library/papers/31519395 | PubMed |
| 11 | 31276385 | Paper-Based All-in-One Origami Microdevice for Nucleic Acid Amplification Testing for Rapid Colorimetric Identification of Live Cells for Point-of-Care Testing. | Anal Chem | 2019 | https://conductscience.org/library/papers/31276385 | PubMed |
| 12 | 29717591 | [Visualized detection for mycobacterium tuberculosis using loop-mediated isothermal amplification assay]. | Sheng Wu Yi Xue Gong Cheng Xue Za Zhi | 2017 | https://conductscience.org/library/papers/29717591 | PubMed |
| 13 | 29896174 | A Rapid and Specific Assay for the Detection of MERS-CoV. | Front Microbiol | 2018 | https://conductscience.org/library/papers/29896174 | PubMed |
| 14 | 30915049 | Rapid and Specific Detection of All Known Nipah virus Strains' Sequences With Reverse Transcription-Loop-Mediated Isothermal Amplification. | Front Microbiol | 2019 | https://conductscience.org/library/papers/30915049 | PubMed |
| 15 | 32530929 | Rapid detection of novel coronavirus/Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) by reverse transcription-loop-mediated isothermal amplification. | PLoS One | 2020 | https://conductscience.org/library/papers/32530929 | PubMed |
| 16 | 31419041 | Rapid point-of-care diagnostics for the detection of Chlamydia pecorum in koalas (Phascolarctos cinereus) using loop-mediated isothermal amplification without nucleic acid purification. | Microbiologyopen | 2019 | https://conductscience.org/library/papers/31419041 | PubMed |
| 17 | 19396514 | Loop-mediated isothermal amplification (LAMP): a rapid, accurate, and cost-effective diagnostic method for infectious diseases. | J Infect Chemother | 2009 | https://conductscience.org/library/papers/19396514 | PubMed |
| 18 | 22449174 | Multiplex loop-mediated isothermal amplification detection by sequence-based barcodes coupled with nicking endonuclease-mediated pyrosequencing. | Anal Chem | 2012 | https://conductscience.org/library/papers/22449174 | PubMed |
| 19 | 27960145 | Visualized detection of single-base difference in multiplexed loop-mediated isothermal amplification amplicons by invasive reaction coupled with oligonucleotide probe-modified gold nanoparticles. | Biosens Bioelectron | 2017 | https://conductscience.org/library/papers/27960145 | PubMed |
| 20 | 10871386 | Loop-mediated isothermal amplification of DNA. | Nucleic Acids Res | 2000 | https://conductscience.org/library/papers/10871386 | PubMed |
Cited by12
The papers in our copy of PubMed whose reference list names this one, newest first. iCite, which reads more sources, counts 27 citations.
| PMID | Title | Journal | Year | In Papers | Source |
|---|---|---|---|---|---|
| 40946557 | A self-heating, multi-channel slider cassette for innovative point-of-care molecular diagnostics from whole blood samples. | Biosens Bioelectron | 2025 | https://conductscience.org/library/papers/40946557 | PubMed |
| 40687858 | Progress in the application of isothermal amplification technology in the diagnosis of infectious diseases. | Front Microbiol | 2025 | https://conductscience.org/library/papers/40687858 | PubMed |
| 40581715 | Lessons Learned from Liver-on-Chip Platform. | Ann Biomed Eng | 2025 | https://conductscience.org/library/papers/40581715 | PubMed |
| 40317856 | Loop-Mediated Isothermal Amplification (LAMP) for the Diagnosis of Sexually Transmitted Infections: A Review. | Microb Biotechnol | 2025 | https://conductscience.org/library/papers/40317856 | PubMed |
| 39574968 | A paradigm shift in the detection of bloodborne pathogens: conventional approaches to recent detection techniques. | EXCLI J | 2024 | https://conductscience.org/library/papers/39574968 | PubMed |
| 39056624 | Enhanced Point-of-Care SARS-CoV-2 Detection: Integrating RT-LAMP with Microscanning. | Biosensors (Basel) | 2024 | https://conductscience.org/library/papers/39056624 | PubMed |
| 38137872 | Point-of-Care Testing for Hepatitis Viruses: A Growing Need. | Life (Basel) | 2023 | https://conductscience.org/library/papers/38137872 | PubMed |
| 36551035 | LAMP-Based Point-of-Care Biosensors for Rapid Pathogen Detection. | Biosensors (Basel) | 2022 | https://conductscience.org/library/papers/36551035 | PubMed |
| 36349548 | A microfluidic fully paper-based analytical device integrated with loop-mediated isothermal amplification and nano-biosensors for rapid, sensitive, and specific quantitative detection of infectious diseases. | Lab Chip | 2022 | https://conductscience.org/library/papers/36349548 | PubMed |
| 36290994 | Principles and Applications of Loop-Mediated Isothermal Amplification to Point-of-Care Tests. | Biosensors (Basel) | 2022 | https://conductscience.org/library/papers/36290994 | PubMed |
| 35735571 | SMART-LAMP: A Smartphone-Operated Handheld Device for Real-Time Colorimetric Point-of-Care Diagnosis of Infectious Diseases via Loop-Mediated Isothermal Amplification. | Biosensors (Basel) | 2022 | https://conductscience.org/library/papers/35735571 | PubMed |
| 35657389 | Analysis and validation of silica-immobilised BST polymerase in loop-mediated isothermal amplification (LAMP) for malaria diagnosis. | Anal Bioanal Chem | 2022 | https://conductscience.org/library/papers/35657389 | PubMed |
Data dates
The date of each source this release read.
- Trials
- 2026-11-12
- Gene search
- 2026-11-11
- Pipelines
- 2026-09-18
None in this release
- Trials
- Comments and corrections
- Genes
- Drugs
- Data
Sources 11
- ChEMBL, through Open TargetsCC BY-SA 3.0
- ClinicalTrials.govNo license stated
- HGNCCC0
- iCiteCC BY 4.0
- NCBI GenePublic domain (US government)
- NIH RePORTER's grant and paper linksPublic domain
- Open TargetsCC0 1.0
- PMC's ID filePublic domain (US government)
- PubMedNLM's terms
- PubTator 3Public domain
- UniProtCC BY 4.0
Each source's terms
- ChEMBL, through Open TargetsCC BY-SA 3.0, for the parts from ChEMBL. Read on 8 Nov 2026 at https://platform-docs.opentargets.org/licence
- ClinicalTrials.govnone stated
- HGNCCC0: https://www.genenames.org/about/license/
- iCiteCC BY 4.0
- NCBI GeneNone named for the file. NCBI says information created by or for the US government on its site is in the public domain, and asks that NLM be acknowledged: https://www.ncbi.nlm.nih.gov/home/about/policies/
- NIH RePORTER's grant and paper linksPublic domain (NIH RePORTER)
- Open TargetsCC0 1.0. Open Targets asks that users cite its latest paper: Buniello et al. 2025, Open Targets Platform: facilitating therapeutic hypotheses building in drug discovery, Nucleic Acids Research 53(D1):D1467, PMID 39657122. Read on 8 Nov 2026 at https://platform-docs.opentargets.org/licence
- PMC's ID fileNone named for the file. NCBI says information created by or for the US government on its site is in the public domain, and asks that NLM be acknowledged: https://www.ncbi.nlm.nih.gov/home/about/policies/
- PubMedNLM's terms
- PubTator 3Public domain
- UniProtCC BY 4.0. UniProt's licence file: "All databases and documents in the UniProt FTP directory may be copied and redistributed freely, without advance permission, provided that this copyright statement is reproduced with each copy." UniProt asks that users cite its latest paper: The UniProt Consortium, UniProt: the Universal Protein Knowledgebase in 2025, Nucleic Acids Research 53:D609-D617, https://doi.org/10.1093/nar/gkae1010. Read on 9 Nov 2026 at https://www.uniprot.org/help/license
ClinicalTrials.gov's data carry an international copyright outside the United States: https://clinicaltrials.gov/about-site/terms-conditions.
For software
Read this paper from software.
The record and each of its lists are JSON, twenty rows a page. No key.
GET https://conductscience.org/api/papers/v1/33712918
GET https://conductscience.org/api/papers/v1/33712918/references?page=2