ConductScience.org, home

Trial · NCT00246740

Protection of the Heart With Doxycycline During Coronary Artery Bypass Grafting

NCT00246740, Phase 2, Completed, University of Alberta; results first posted 2017-12-15

3 sourcestrials-2026-11-12-0.5.0

Download JSON
Cite this record

ConductScience Library. Protection of the Heart With Doxycycline During Coronary Artery Bypass Grafting. Trials, record NCT00246740. Release trials-2026-11-12-0.5.0, 12 Nov 2026. https://conductscience.org/library/trials/NCT00246740

On this page

Trial

As registered on ClinicalTrials.gov, in the graph's capture of the registry.

Title
Protection of the Heart With Doxycycline During Coronary Artery Bypass Grafting
NCT number
NCT00246740
Status
Completed
Phases
Phase 2
Enrollment
56 participants, actual
Lead sponsor
University of Alberta
Conditions
Coronary Artery Bypass Grafting, Cardiopulmonary Bypass, Reperfusion Injury
Interventions
Periostat, Placebo Oral Tablet
First posted
2005-10-31
Last updated
2017-12-15
Results first posted
2017-12-15
Limitations and caveats
Small sample size. LVSWI does not estimate diastolic dysfunction. Right atrial biopsies may not reflect changes in left ventricular MMP activity. Doxycycline dose- and time-response analyses is required to better assess the protective effects

Source ClinicalTrials.gov

Registered outcomes9

Each outcome the trial registered, primary first, in ClinicalTrials.gov's words.

ListOutcomeTime frameDescription
PrimaryLeft Ventricular Stroke Work Index (LVSWI)Before surgery up to 24h of reperfusion
Measure of global left ventricular function. The formula used for calculation is: LVSWI= SI x MAP x 0.0144 LVSWI = Left Ventricular Stroke Work Index (g\*m/m2) SI = Stroke Index (mL/beat/m2) MAP = Mean Arterial Pressure (mmHg) 0.0144 is a conversion term to equalize units.
SecondaryCardiac Matrix Metalloproteinase-9 Activity in Right Atrial Biopsies at 10 Minutes ReperfusionBefore surgery and 10 minutes reperfusion after surgery
Biochemical activity of MMP-9 activity in right atrial biopsies, measured at 10 minutes of reperfusion after surgery. To determine MMP-9 activity, 20 μg of total protein from both myocardial extracts and plasma were analyzed by gelatin zymography. For detailed methodology consult Cheung PY, Sawicki G, Wozniak M, et al: Matrix metalloproteinase-2 contributes to ischemia-reperfusion injury in the heart. Circulation 2000; 101:1833-1839
SecondaryCardiac Matrix Metalloproteinase-2 Activity in Right Atrial Biopsies at 10 Minutes ReperfusionBefore surgery and 10 minutes reperfusion after surgeryBiochemical activity of MMP-2 activity in right atrial biopsies, measured at 10 minutes of reperfusion after surgery.
SecondaryVenous Plasma Cardiac Matrix Metalloproteinase-9 Activity Before and After ReperfusionBefore surgery and up to 72 h reperfusion after surgeryBiochemical activity of MMP-9 activity in venous plasma, measured before surgery and up to 72h of reperfusion after surgery.
SecondaryVenous Plasma Cardiac Matrix Metalloproteinase-2 Activity Before and After ReperfusionBefore surgery and up to 72 h reperfusion after surgeryBiochemical activity of MMP-2 activity in venous plasma, measured before surgery and up to 72h of reperfusion after surgery.
SecondaryVenous Plasma Concentration of Troponin-IBefore surgery and 10 minutes reperfusion after surgeryMeasurement of levels of TnI (troponin-I), a marker of cardiac cell damage
SecondaryCleaved TroponinI/GAPDH Ratios in Right Atrial BiopsyBefore surgery and 10 minutes reperfusion after surgeryMeasurement of the ratios of cleaved TnI (troponin-I) versus GAPDH in biopsies collected from right atria. Measure is the ratio TnI/GAPDH
SecondaryVenous Plasma Concentration of C-reactive ProteinBefore surgery and up to 72 h reperfusion after surgeryMeasurement of inflammation marker C-reactive protein in plasma
SecondaryVenous Plasma Concentration of IL-6Before surgery and up to 72 h reperfusion after surgeryMeasurement of inflammation marker interleukin-6 in plasma

Outcomes9

Each outcome the trial posted results for, in ClinicalTrials.gov's words.

TypeOutcomeTime framePopulationUnitsMeasured as
PRIMARYLeft Ventricular Stroke Work Index (LVSWI)Before surgery up to 24h of reperfusiong*m/m2MEAN
SECONDARYCardiac Matrix Metalloproteinase-9 Activity in Right Atrial Biopsies at 10 Minutes ReperfusionBefore surgery and 10 minutes reperfusion after surgeryArbitrary unitsMEAN
SECONDARYCardiac Matrix Metalloproteinase-2 Activity in Right Atrial Biopsies at 10 Minutes ReperfusionBefore surgery and 10 minutes reperfusion after surgeryArbitrary unitsMEAN
SECONDARYVenous Plasma Cardiac Matrix Metalloproteinase-9 Activity Before and After ReperfusionBefore surgery and up to 72 h reperfusion after surgeryArbitrary unitsMEAN
SECONDARYVenous Plasma Cardiac Matrix Metalloproteinase-2 Activity Before and After ReperfusionBefore surgery and up to 72 h reperfusion after surgeryArbitrary unitsMEAN
SECONDARYVenous Plasma Concentration of Troponin-IBefore surgery and 10 minutes reperfusion after surgerypg/mlMEAN
SECONDARYCleaved TroponinI/GAPDH Ratios in Right Atrial BiopsyBefore surgery and 10 minutes reperfusion after surgeryArbitrary units-Cleaved TnI/GAPDHMEAN
SECONDARYVenous Plasma Concentration of C-reactive ProteinBefore surgery and up to 72 h reperfusion after surgeryng/mlMEAN
SECONDARYVenous Plasma Concentration of IL-6Before surgery and up to 72 h reperfusion after surgerypg/mlMEAN

Results by group94

Each measurement the trial posted, group by group, in the words and numbers it posted.

OutcomeGroupCategoryValueSpreadUnits
Left Ventricular Stroke Work Index (LVSWI)Placebo Oral TabletBefore surgery42Standard Error 2.6g*m/m2
Left Ventricular Stroke Work Index (LVSWI)PeriostatBefore surgery43Standard Error 2.5g*m/m2
Left Ventricular Stroke Work Index (LVSWI)Placebo Oral TabletPost surgery29Standard Error 1.7g*m/m2
Left Ventricular Stroke Work Index (LVSWI)PeriostatPost surgery28Standard Error 1.7g*m/m2
Left Ventricular Stroke Work Index (LVSWI)Placebo Oral Tablet1h reperfusion30Standard Error 1.8g*m/m2
Left Ventricular Stroke Work Index (LVSWI)Periostat1h reperfusion29Standard Error 1.9g*m/m2
Left Ventricular Stroke Work Index (LVSWI)Placebo Oral Tablet3h reperfusion31Standard Error 1.9g*m/m2
Left Ventricular Stroke Work Index (LVSWI)Periostat3h reperfusion29Standard Error 2g*m/m2
Left Ventricular Stroke Work Index (LVSWI)Placebo Oral Tablet6h reperfusion28Standard Error 1.4g*m/m2
Left Ventricular Stroke Work Index (LVSWI)Periostat6h reperfusion25Standard Error 1.4g*m/m2

Participant flow12

How many started, completed or left each group, period by period.

PeriodMilestoneGroupParticipantsUnits counted
Initial EnrollmentSTARTEDPlacebo Oral Tablet28
Initial EnrollmentSTARTEDPeriostat28
Initial EnrollmentCOMPLETEDPlacebo Oral Tablet22
Initial EnrollmentCOMPLETEDPeriostat20
Initial EnrollmentNOT COMPLETEDPlacebo Oral Tablet6
Initial EnrollmentNOT COMPLETEDPeriostat8
Experimental PhaseSTARTEDPlacebo Oral Tablet22
Experimental PhaseSTARTEDPeriostat20
Experimental PhaseCOMPLETEDPlacebo Oral Tablet22
Experimental PhaseCOMPLETEDPeriostat20

Adverse events0

Each adverse event the trial posted, group by group: the participants affected out of those at risk.

None in this release.

Adverse event totals6

The totals the trial posted for each group.

TotalGroupAffectedAt risk
Total, all-cause mortalityPlacebo Oral Tablet022
Total, all-cause mortalityPeriostat020
Total, other adverse eventsPlacebo Oral Tablet022
Total, other adverse eventsPeriostat020
Total, serious adverse eventsPlacebo Oral Tablet022
Total, serious adverse eventsPeriostat020

Papers1

The papers the trial lists on ClinicalTrials.gov.

PMIDListed as
23928836RESULT

Source PubMed

Grants0

The grants NIH RePORTER links to the trial, newest funded first: NIH's, and some of AHRQ's, CDC's, FDA's and VA's. Each shows its title, principal investigators, organization and funder in its newest year.

None in this release.

Trial comparisons2

Comparisons of the trial's two groups, calculated by ConductScience from the counts it posted.

ComparisonSource
Periostat vs Placebo Oral Tablet: deaths from any causeTrial comparisons
Periostat vs Placebo Oral Tablet: serious adverse eventsTrial comparisons

Tests0

The ConductCognition tests this trial's registered outcomes name, as ScienceGraph matched them in trial-tests-2026-11-12-0.2.1.

None in this release.

Data dates

The day each source was copied for this release.

ClinicalTrials.gov
2026-11-12
ClinicalTrials.gov
Results, from AACT
2026-03-23
AACT
NIH grant links
2026-11-13
NIH RePORTER

Sources 3

  • ClinicalTrials.gov's posted results, through CTTI's AACTFreely available. Acknowledgement requested
  • ClinicalTrials.govNo license stated
  • NIH RePORTER's clinical studies and project filesPublic domain
Each source's terms
  • ClinicalTrials.gov's posted results, through CTTI's AACTClinicalTrials.gov data via Aggregate Analysis of ClinicalTrials.gov (AACT), CTTI. CTTI makes its materials freely available and requests acknowledgement. https://aact.ctti-clinicaltrials.org/documentation/299
  • ClinicalTrials.govnone stated
  • NIH RePORTER's clinical studies and project filesPublic domain (NIH RePORTER)

ClinicalTrials.gov's data carry an international copyright outside the United States: https://clinicaltrials.gov/about-site/terms-conditions.

For software

Read this trial from software.

The record and each of its lists are JSON, twenty rows a page. No key.

GET https://conductscience.org/api/trials/v1/NCT00246740

GET https://conductscience.org/api/trials/v1/NCT00246740/results?page=2