ConductScience.org, home

Trial · NCT00503399

Results by group62

Each measurement the trial posted, group by group, in the words and numbers it posted.

OutcomeGroupCategoryValueSpreadUnits
Change From Baseline in Lumbar Spine Volumetric Trabecular Bone Mineral Density (BMD) by Quantitative Computerized Tomography (QCT) at 18 MonthsTeriparatide12.28Standard Error 3.16milligram per cubic centimeter (mg/cm^3)
Change From Baseline in Lumbar Spine Volumetric Trabecular Bone Mineral Density (BMD) by Quantitative Computerized Tomography (QCT) at 18 MonthsRisedronate2.94Standard Error 3.14milligram per cubic centimeter (mg/cm^3)
Change From Baseline in Lumbar Spine Volumetric Trabecular Bone Mineral Density (BMD) by Quantitative Computerized Technology (QCT) at 6 MonthsTeriparatide4.31Standard Error 3.15milligram per cubic centimeter (mg/cm^3)
Change From Baseline in Lumbar Spine Volumetric Trabecular Bone Mineral Density (BMD) by Quantitative Computerized Technology (QCT) at 6 MonthsRisedronate2.52Standard Error 3.16milligram per cubic centimeter (mg/cm^3)
Change From Baseline in High Resolution Quantitative Computerized Technology (HR-QCT) of Integral and Trabecular Bone Mineral Density (BMD) of the 12th Thoracic Vertebra (T12) at 6 Months and 18 Months
TeriparatideIntegral BMD at 6 months-0.42Standard Error 6.42milligram per cubic centimeter (mg/cm^3)
Change From Baseline in High Resolution Quantitative Computerized Technology (HR-QCT) of Integral and Trabecular Bone Mineral Density (BMD) of the 12th Thoracic Vertebra (T12) at 6 Months and 18 Months
RisedronateIntegral BMD at 6 months-1.91Standard Error 7.11milligram per cubic centimeter (mg/cm^3)
Change From Baseline in High Resolution Quantitative Computerized Technology (HR-QCT) of Integral and Trabecular Bone Mineral Density (BMD) of the 12th Thoracic Vertebra (T12) at 6 Months and 18 Months
TeriparatideIntegral BMD at 18 months10.72Standard Error 6.22milligram per cubic centimeter (mg/cm^3)
Change From Baseline in High Resolution Quantitative Computerized Technology (HR-QCT) of Integral and Trabecular Bone Mineral Density (BMD) of the 12th Thoracic Vertebra (T12) at 6 Months and 18 Months
RisedronateIntegral BMD at 18 months0.68Standard Error 7.08milligram per cubic centimeter (mg/cm^3)
Change From Baseline in High Resolution Quantitative Computerized Technology (HR-QCT) of Integral and Trabecular Bone Mineral Density (BMD) of the 12th Thoracic Vertebra (T12) at 6 Months and 18 Months
TeriparatideTrabecular BMD at 6 months-0.70Standard Error 5.26milligram per cubic centimeter (mg/cm^3)
Change From Baseline in High Resolution Quantitative Computerized Technology (HR-QCT) of Integral and Trabecular Bone Mineral Density (BMD) of the 12th Thoracic Vertebra (T12) at 6 Months and 18 Months
RisedronateTrabecular BMD at 6 months-0.87Standard Error 5.85milligram per cubic centimeter (mg/cm^3)
Change From Baseline in High Resolution Quantitative Computerized Technology (HR-QCT) of Integral and Trabecular Bone Mineral Density (BMD) of the 12th Thoracic Vertebra (T12) at 6 Months and 18 Months
TeriparatideTrabecular BMD at 18 months9.53Standard Error 5.09milligram per cubic centimeter (mg/cm^3)
Change From Baseline in High Resolution Quantitative Computerized Technology (HR-QCT) of Integral and Trabecular Bone Mineral Density (BMD) of the 12th Thoracic Vertebra (T12) at 6 Months and 18 Months
RisedronateTrabecular BMD at 18 months0.22Standard Error 5.82milligram per cubic centimeter (mg/cm^3)
Change From Baseline in Anterior Bending and Axial Torsion by Finite Element Analysis in the 12th Thoracic Vertebra (T12) at 6 Months and 18 Months: Stiffness and StrengthTeriparatideAnterior bending stiffness at 6 months664969.0Standard Error 317684.0Newton/millimeter/radian (N/mm/rad)
Change From Baseline in Anterior Bending and Axial Torsion by Finite Element Analysis in the 12th Thoracic Vertebra (T12) at 6 Months and 18 Months: Stiffness and StrengthRisedronateAnterior bending stiffness at 6 months415705.0Standard Error 323135.0Newton/millimeter/radian (N/mm/rad)
Change From Baseline in Anterior Bending and Axial Torsion by Finite Element Analysis in the 12th Thoracic Vertebra (T12) at 6 Months and 18 Months: Stiffness and StrengthTeriparatideAnterior bending stiffness at 18 months1209225.0Standard Error 300977.0Newton/millimeter/radian (N/mm/rad)
Change From Baseline in Anterior Bending and Axial Torsion by Finite Element Analysis in the 12th Thoracic Vertebra (T12) at 6 Months and 18 Months: Stiffness and StrengthRisedronateAnterior bending stiffness at 18 months233283.0Standard Error 322829.0Newton/millimeter/radian (N/mm/rad)
Change From Baseline in Anterior Bending and Axial Torsion by Finite Element Analysis in the 12th Thoracic Vertebra (T12) at 6 Months and 18 Months: Stiffness and StrengthTeriparatideAxial torsion stiffness at 6 months142902.9Standard Error 71714.2Newton/millimeter/radian (N/mm/rad)
Change From Baseline in Anterior Bending and Axial Torsion by Finite Element Analysis in the 12th Thoracic Vertebra (T12) at 6 Months and 18 Months: Stiffness and StrengthRisedronateAxial torsion stiffness at 6 months77830.7Standard Error 72947.9Newton/millimeter/radian (N/mm/rad)
Change From Baseline in Anterior Bending and Axial Torsion by Finite Element Analysis in the 12th Thoracic Vertebra (T12) at 6 Months and 18 Months: Stiffness and StrengthTeriparatideAxial torsion stiffness at 18 months279392.8Standard Error 68284.5Newton/millimeter/radian (N/mm/rad)
Change From Baseline in Anterior Bending and Axial Torsion by Finite Element Analysis in the 12th Thoracic Vertebra (T12) at 6 Months and 18 Months: Stiffness and StrengthRisedronateAxial torsion stiffness at 18 months56639.3Standard Error 72946.9Newton/millimeter/radian (N/mm/rad)

Source ClinicalTrials.govtrials-2026-11-12-0.5.0

Sources 3

  • ClinicalTrials.gov's posted results, through CTTI's AACTFreely available. Acknowledgement requested
  • ClinicalTrials.govNo license stated
  • NIH RePORTER's clinical studies and project filesPublic domain
Each source's terms
  • ClinicalTrials.gov's posted results, through CTTI's AACTClinicalTrials.gov data via Aggregate Analysis of ClinicalTrials.gov (AACT), CTTI. CTTI makes its materials freely available and requests acknowledgement. https://aact.ctti-clinicaltrials.org/documentation/299
  • ClinicalTrials.govnone stated
  • NIH RePORTER's clinical studies and project filesPublic domain (NIH RePORTER)

ClinicalTrials.gov's data carry an international copyright outside the United States: https://clinicaltrials.gov/about-site/terms-conditions.

For software

Read this list from software.

Twenty rows a page, as JSON. No key.