ConductScience.org, home

Trial · NCT01082640

Results by group21

Each measurement the trial posted, group by group, in the words and numbers it posted.

OutcomeGroupCategoryValueSpreadUnits
Change From Baseline to Month 12 in Serum CreatininePlaceboBaseline2.52Standard Error 0.126mg/dL
Change From Baseline to Month 12 in Serum CreatinineFebuxostat 30 mg BIDBaseline2.10Standard Error 0.126mg/dL
Change From Baseline to Month 12 in Serum CreatinineFebuxostat 40/80 mg QDBaseline2.22Standard Error 0.128mg/dL
Change From Baseline to Month 12 in Serum CreatininePlaceboChange from Baseline at Month 120.19Standard Error 0.094mg/dL
Change From Baseline to Month 12 in Serum CreatinineFebuxostat 30 mg BIDChange from Baseline at Month 120.09Standard Error 0.093mg/dL
Change From Baseline to Month 12 in Serum CreatinineFebuxostat 40/80 mg QDChange from Baseline at Month 120.23Standard Error 0.094mg/dL
Change From Baseline to Month 12 in Estimated Glomerular Filtration Rate (eGFR)PlaceboBaseline29.31Standard Error 1.461mL/min/1.73m²
Change From Baseline to Month 12 in Estimated Glomerular Filtration Rate (eGFR)Febuxostat 30 mg BIDBaseline34.14Standard Error 1.461mL/min/1.73m²
Change From Baseline to Month 12 in Estimated Glomerular Filtration Rate (eGFR)Febuxostat 40/80 mg QDBaseline34.08Standard Error 1.484mL/min/1.73m²
Change From Baseline to Month 12 in Estimated Glomerular Filtration Rate (eGFR)PlaceboChange from Baseline at Month 12-2.05Standard Error 1.198mL/min/1.73m²
Change From Baseline to Month 12 in Estimated Glomerular Filtration Rate (eGFR)Febuxostat 30 mg BIDChange from Baseline at Month 120.33Standard Error 1.172mL/min/1.73m²
Change From Baseline to Month 12 in Estimated Glomerular Filtration Rate (eGFR)Febuxostat 40/80 mg QDChange from Baseline at Month 12-0.86Standard Error 0.190mL/min/1.73m²
Percentage of Participants With Serum Urate (sUA) Less Than 6 mg/dL at Month 12Placebo0percentage of participants
Percentage of Participants With Serum Urate (sUA) Less Than 6 mg/dL at Month 12Febuxostat 30 mg BID68.8percentage of participants
Percentage of Participants With Serum Urate (sUA) Less Than 6 mg/dL at Month 12Febuxostat 40/80 mg QD45.2percentage of participants
Mean Clearance (CL/F) of Febuxostat at Steady StateFebuxostat 30 mg BID8.16Standard Deviation 2.31liters/hour
Mean Clearance (CL/F) of Febuxostat at Steady StateFebuxostat 40 mg QD8.71Standard Deviation 2.21liters/hour
Mean Clearance (CL/F) of Febuxostat at Steady StateFebuxostat 80 mg QD10.9Standard Deviation 4.70liters/hour
Mean Area Under the Concentration-Time Curve During the Dosing Interval (AUC[0-τ]) of Febuxostat at Steady StateFebuxostat 30 mg BID3.98Standard Deviation 1.21hr*µg/mL
Mean Area Under the Concentration-Time Curve During the Dosing Interval (AUC[0-τ]) of Febuxostat at Steady StateFebuxostat 40 mg QD4.91Standard Deviation 1.29hr*µg/mL

Source ClinicalTrials.govtrials-2026-11-12-0.5.0

Sources 3

  • ClinicalTrials.gov's posted results, through CTTI's AACTFreely available. Acknowledgement requested
  • ClinicalTrials.govNo license stated
  • NIH RePORTER's clinical studies and project filesPublic domain
Each source's terms
  • ClinicalTrials.gov's posted results, through CTTI's AACTClinicalTrials.gov data via Aggregate Analysis of ClinicalTrials.gov (AACT), CTTI. CTTI makes its materials freely available and requests acknowledgement. https://aact.ctti-clinicaltrials.org/documentation/299
  • ClinicalTrials.govnone stated
  • NIH RePORTER's clinical studies and project filesPublic domain (NIH RePORTER)

ClinicalTrials.gov's data carry an international copyright outside the United States: https://clinicaltrials.gov/about-site/terms-conditions.

For software

Read this list from software.

Twenty rows a page, as JSON. No key.

GET https://conductscience.org/api/trials/v1/NCT01082640/results