ConductScience.org, home

Trial · NCT01376362

Results by group17

Each measurement the trial posted, group by group, in the words and numbers it posted.

OutcomeGroupCategoryValueSpreadUnits
Change in Excess Central Macular Thickening in the Study Eye, as Measured by Optical Coherence Tomography (OCT), at Week One Compared to BaselineInterferon Gamma-1b-38.60Standard Deviation 130.26µm
Change in Excess Central Macular Thickening in the Fellow Eye, as Measured by Optical Coherence Tomography (OCT), at Week One Compared to BaselineInterferon Gamma-1b12.00Standard Deviation 29.12µm
Change in Excess Central Macular Thickening in the Study Eye, as Measured by Optical Coherence Tomography (OCT), at Week Two Compared to BaselineInterferon Gamma-1b-47.40Standard Deviation 85.96µm
Change in Excess Central Macular Thickening in the Fellow Eye, as Measured by Optical Coherence Tomography (OCT), at Week Two Compared to BaselineInterferon Gamma-1b30.20Standard Deviation 64.43µm
Change in Macular Volume in the Study Eye, as Measured by Optical Coherence Tomography (OCT), at Week One Compared to BaselineInterferon Gamma-1b-0.02Standard Deviation 0.36mm^3
Change in Macular Volume in the Fellow Eye, as Measured by Optical Coherence Tomography (OCT), at Week One Compared to BaselineInterferon Gamma-1b0.14Standard Deviation 0.21mm^3
Change in Macular Volume in the Study Eye, as Measured by Optical Coherence Tomography (OCT), at Week Two Compared to BaselineInterferon Gamma-1b0.00Standard Deviation 0.32mm^3
Change in Macular Volume in the Fellow Eye, as Measured by Optical Coherence Tomography (OCT), at Week Two Compared to BaselineInterferon Gamma-1b0.06Standard Deviation 0.34mm^3
Change in ETDRS Best-corrected Visual Acuity (BCVA) in the Study Eye at Week One Compared to BaselineInterferon Gamma-1b0.20Standard Deviation 5.63ETDRS Letters
Change in ETDRS Best-corrected Visual Acuity (BCVA) in the Fellow Eye at Week One Compared to BaselineInterferon Gamma-1b1.60Standard Deviation 4.72ETDRS Letters
Change in ETDRS Best-corrected Visual Acuity (BCVA) in the Study Eye at Week Two Compared to BaselineInterferon Gamma-1b4.00Standard Deviation 9.03ETDRS Letters
Change in ETDRS Best-corrected Visual Acuity (BCVA) in the Fellow Eye at Week Two Compared to BaselineInterferon Gamma-1b3.20Standard Deviation 6.87ETDRS Letters
Change in Intraocular Pressure (IOP) in the Study Eye at Week One Compared to BaselineInterferon Gamma-1b0.40Standard Deviation 2.07mm Hg
Change in Intraocular Pressure (IOP) in the Fellow Eye at Week One Compared to BaselineInterferon Gamma-1b-1.60Standard Deviation 7.02mm Hg
Change in Intraocular Pressure (IOP) in the Study Eye at Week Two Compared to BaselineInterferon Gamma-1b0.40Standard Deviation 1.34mm Hg
Change in Intraocular Pressure (IOP) in the Fellow Eye at Week Two Compared to BaselineInterferon Gamma-1b-2.20Standard Deviation 7.40mm Hg
Proportion of Participants With a Visual Loss of 15 or More Early Treatment Diabetic Retinopathy Study (ETDRS) Letters in the Study EyeInterferon Gamma-1b0Percentage of Participants

Source ClinicalTrials.govtrials-2026-11-12-0.5.0

Sources 3

  • ClinicalTrials.gov's posted results, through CTTI's AACTFreely available. Acknowledgement requested
  • ClinicalTrials.govNo license stated
  • NIH RePORTER's clinical studies and project filesPublic domain
Each source's terms
  • ClinicalTrials.gov's posted results, through CTTI's AACTClinicalTrials.gov data via Aggregate Analysis of ClinicalTrials.gov (AACT), CTTI. CTTI makes its materials freely available and requests acknowledgement. https://aact.ctti-clinicaltrials.org/documentation/299
  • ClinicalTrials.govnone stated
  • NIH RePORTER's clinical studies and project filesPublic domain (NIH RePORTER)

ClinicalTrials.gov's data carry an international copyright outside the United States: https://clinicaltrials.gov/about-site/terms-conditions.

For software

Read this list from software.

Twenty rows a page, as JSON. No key.

GET https://conductscience.org/api/trials/v1/NCT01376362/results