ConductScience.org, home

Trial · NCT01589978

Registered outcomes21

Each outcome the trial registered, primary first, in ClinicalTrials.gov's words.

ListOutcomeTime frameDescription
PrimaryCardiac Death or Myocardial Infarction Rate in PLATINUM-like Patients12 months
Cardiac death or myocardial infarction rate at 12 months post implantation in PLATINUM-like patients (no acute myocardial infarction, graft stenting, chronic total occlusion, in-stent restenosis, failed brachytherapy, bifurcation, ostial lesion, severe tortuosity, moderate/severe calcification, 3-vessel stenting, cardiogenic shock, left main disease, or acute/chronic renal dysfunction; lesion length ≤28 mm with reference vessel diameter ≥2.25 mm and \<2.5 mm, or lesion length ≤24 mm with diameter ≥2.5 mm and ≤4.25 mm); statistical testing will assess if rate meets the performance goal (3.2%)
SecondaryDefinite + Probable Stent Thrombosis (ST) Rate Based on Academic Research Consortium (ARC) Definition in PLATINUM-like Patients12 months
ARC definite/probable ST rate in PLATINUM-like patients (no acute myocardial infarction, graft stenting, chronic total occlusion, in-stent restenosis, failed brachytherapy, bifurcation, ostial lesion, severe tortuosity, moderate/severe calcification, 3-vessel stenting, cardiogenic shock, left main disease, or acute/chronic renal dysfunction; lesion length ≤28 mm with reference vessel diameter ≥2.25 mm and \<2.5 mm, or lesion length ≤24 mm with diameter ≥2.5 mm and ≤4.25 mm); statistical testing will assess if the annual ST rate increase after the first year meets the performance goal (1.0%)
SecondaryDefinite + Probable Stent Thrombosis (ST) Rate Based on Academic Research Consortium (ARC) Definition in All Patients≤24 hours, 30 days, 180 days, annually through 5 years
DEFINITE ST: acute coronary syndrome and angiographic or pathologic evidence of stent thrombosis; PROBABLE ST: unexplained death within 30 days or target-vessel infarction without angiographic information ARC ST is reported as a cumulative value at different time points and within the different separate time points. Time 0 is the time point after the guide catheter has been removed. Acute ST: 0-24 hours after stent implantation; Subacute ST: \>24 hours to 30 days post; late ST: \>30 days to 1 year post; Very late ST: \>1 year post; NOTE: Acute/subacute can be replaced by early ST (0-30 days)
SecondaryRate of Longitudinal Stent DeformationIndex Procedure
Compression/elongation of a stent along its long axis resulting from interaction with an ancillary device (e.g., guide catheter) which catches the stent end or an internal stent strut; can occur with advancement or withdrawal of ancillary device. Under fluoroscopy, longitudinal compression usually results in increased strut density and elongation in decreased strut density ('pseudo-fracture'); both can occur in the same stent.
SecondaryMajor Adverse Cardiac Event Rate (MACE)≤24 hours, 30 days, 180 days, annually through 5 yearsComposite of cardiac death, myocardial infarction, and target vessel revascularization
SecondaryRate of Major Adverse Cardiac Events Related to the PROMUS Element Stent≤24 hours, 30 days, 180 days, annually through 5 yearsComposite of cardiac death, myocardial infarction, and target vessel revascularization related to the PROMUS Element stent
SecondaryMyocardial Infarction (MI) Rate≤24 hours, 30 days, 180 days, annually through 5 years
New Q-waves in ≥2 leads lasting ≥0.04 sec with creatine kinase myoglobin band(CK-MB) or troponin \>upper limit of normal(ULN); if no new Q-waves total CK levels \>3×ULN (peri-percutaneous coronary intervention \[PCI\]) or \>2×ULN (spontaneous) with elevated CK-MB or troponin \>3×ULN (peri-PCI) or \>2×ULN (spontaneous) plus ≥one of the following: ECG changes indicating new ischemia (new ST-T changes, left bundle branch block), imaging evidence of new loss of viable myocardium, new regional wall motion abnormality. Similar for MI diagnosis post coronary artery bypass graft with CK-MB or troponin \>5×ULN
SecondaryRate of Myocardial Infarction (MI) Events Related to the PROMUS Element Stent≤24 hours, 30 days, 180 days, annually through 5 years
New Q-waves in ≥2 leads lasting ≥0.04 sec with creatine kinase myoglobin band(CK-MB) or troponin \>upper limit of normal(ULN); if no new Q-waves total CK levels \>3×ULN (peri-percutaneous coronary intervention \[PCI\]) or \>2×ULN (spontaneous) with elevated CK-MB or troponin \>3×ULN (peri-PCI) or \>2×ULN (spontaneous) plus ≥one of the following: ECG changes indicating new ischemia (new ST-T changes, left bundle branch block), imaging evidence of new loss of viable myocardium, new regional wall motion abnormality. Similar for MI diagnosis post coronary artery bypass graft with CK-MB or troponin \>5×ULN
SecondaryCardiac Death Rate≤24 hours, 30 days, 180 days, annually through 5 years
Cardiac death is defined as death due to any of the following: acute myocardial infarction; cardiac perforation/pericardial tamponade; arrhythmia or conduction abnormality; cerebrovascular accident through hospital discharge or cerebrovascular accident suspected of being related to the procedure; death due to complication of the procedure, including bleeding, vascular repair, transfusion reaction, or bypass surgery; any death in which a cardiac cause cannot be excluded
SecondaryRate of Cardiac Death Events Related to the PROMUS Element Stent≤24 hours, 30 days, 180 days, annually through 5 years
Cardiac death is defined as death due to any of the following: acute myocardial infarction; cardiac perforation/pericardial tamponade; arrhythmia or conduction abnormality; cerebrovascular accident through hospital discharge or cerebrovascular accident suspected of being related to the procedure; death due to complication of the procedure, including bleeding, vascular repair, transfusion reaction, or bypass surgery; any death in which a cardiac cause cannot be excluded
SecondaryTarget Vessel Revascularization (TVR) Rate≤24 hours, 30 days, 180 days, annually through 5 yearsTarget vessel revascularization is defined as any attempted or successfully completed percutaneous or surgical revascularization of a target vessel.
SecondaryRate of Target Vessel Revascularization (TVR) Events Related to the PROMUS Element Stent≤24 hours, 30 days, 180 days, annually through 5 yearsTarget vessel revascularization is defined as any attempted or successfully completed percutaneous or surgical revascularization of a target vessel.
SecondaryCardiac Death or Myocardial Infarction (MI) Rate≤24 hours, 30 days, 180 days, annually through 5 yearsSee individual descriptions of events.
SecondaryRate of Cardiac Death or Myocardial Infarction Events Related to the PROMUS Element Stent≤24 hours, 30 days, 180 days, annually through 5 yearsSee individual descriptions of events.
SecondaryTarget Vessel Failure (TVF) Rate≤24 hours, 30 days, 180 days, annually through 5 years
Target vessel failure (TVF) is defined as any revascularization of the target vessel, myocardial infarction (MI) related to the target vessel, or death related to the target vessel. For the purposes of this protocol, if it cannot be determined with certainty whether MI or death was related to the target vessel it will be considered TVF.
SecondaryRate of Target Vessel Failure (TVF) Related to the PROMUS Element Stent≤24 hours, 30 days, 180 days, annually through 5 years
Target vessel failure (TVF) is defined as any revascularization of the target vessel, myocardial infarction (MI) related to the target vessel, or death related to the target vessel. For the purposes of this protocol, if it cannot be determined with certainty whether MI or death was related to the target vessel it will be considered TVF.
SecondaryAll Death Rate≤24 hours, 30 days, 180 days, annually through 5 yearsAll death includes cardiac death and non-cardiac death.
SecondaryNon-cardiac Death Rate≤24 hours, 30 days, 180 days, annually through 5 years
Non-cardiac death is defined as death not due to cardiac causes. Cardiac death is death due to any of the following: acute myocardial infarction; cardiac perforation/pericardial tamponade; arrhythmia or conduction abnormality; cerebrovascular accident through hospital discharge or cerebrovascular accident suspected of being related to the procedure; death due to complication of the procedure, including bleeding, vascular repair, transfusion reaction, or bypass surgery; any death in which a cardiac cause cannot be excluded.
SecondaryAll Death or Myocardial Infarction Rate≤24 hours, 30 days, 180 days, annually through 5 yearsSee description of individual events.
SecondaryTarget Vessel Failure (TVF) Rate in PLATINUM-like Medically Treated Diabetic Patients12 Months
Any revascularization of the target vessel, myocardial infarction related to the target vessel, or death related to the target vessel. See individual components for descriptions. Statistical testing will determine if the rate meets the performance goal (12.6%)

Source ClinicalTrials.govtrials-2026-11-12-0.5.0

Sources 3

  • ClinicalTrials.gov's posted results, through CTTI's AACTFreely available. Acknowledgement requested
  • ClinicalTrials.govNo license stated
  • NIH RePORTER's clinical studies and project filesPublic domain
Each source's terms
  • ClinicalTrials.gov's posted results, through CTTI's AACTClinicalTrials.gov data via Aggregate Analysis of ClinicalTrials.gov (AACT), CTTI. CTTI makes its materials freely available and requests acknowledgement. https://aact.ctti-clinicaltrials.org/documentation/299
  • ClinicalTrials.govnone stated
  • NIH RePORTER's clinical studies and project filesPublic domain (NIH RePORTER)

ClinicalTrials.gov's data carry an international copyright outside the United States: https://clinicaltrials.gov/about-site/terms-conditions.

For software

Read this list from software.

Twenty rows a page, as JSON. No key.

GET https://conductscience.org/api/trials/v1/NCT01589978/registered