ConductScience.org, home

Trial ยท NCT01838655

Nitisinone for Type 1B Oculocutaneous Albinism

NCT01838655, Phase 1, Phase 2, Completed, National Eye Institute (NEI); results first posted 2017-11-17

3 sourcestrials-2026-11-12-0.5.0

Download JSON
Cite this record

ConductScience Library. Nitisinone for Type 1B Oculocutaneous Albinism. Trials, record NCT01838655. Release trials-2026-11-12-0.5.0, 12 Nov 2026. https://conductscience.org/library/trials/NCT01838655

On this page

Trial

As registered on ClinicalTrials.gov, in the graph's capture of the registry.

Title
Nitisinone for Type 1B Oculocutaneous Albinism
NCT number
NCT01838655
Status
Completed
Phases
Phase 1, Phase 2
Enrollment
5 participants, actual
Lead sponsor
National Eye Institute (NEI)
Conditions
Albinism, Vision Loss
Interventions
Nitisinone
First posted
2013-04-24
Last updated
2019-02-26
Results first posted
2017-11-17

Source ClinicalTrials.gov

Registered outcomes65

Each outcome the trial registered, primary first, in ClinicalTrials.gov's words.

ListOutcomeTime frameDescription
PrimaryAbsolute Mean Change in Iris Pigmentation on an 8-point Iris Transillumination Scale at 12 Months as Compared to Baseline. Participants Left and Right Eyes Will be Analyzed.Baseline and 12 months
High-resolution (2544x1696) digital images of the anterior segment of both eyes were captured prior to pupil dilation using diffuse illumination and iris transillumination. An independent reviewer selected two transillumination images from each eye of each participant for each visit according to preset quality criteria. Images were coded, randomized and presented to a panel of 18 graders on a SHARP 90" HD LED TV. After instruction and a practice dataset, graders scored each image using an 8-point scale. Graders could score images with a single decimal place if they felt an image fell in between two of the standards. The iris transillumination scale ranged from 0 to 8, with lower scores reflective of greater iris pigmentation (melanin content). The mean across all graders and the two images for each participant's eye at baseline and 12 months was calculated; these mean grades were then used to calculate absolute change from baseline at 12 months.
SecondaryAbsolute Mean Change in Iris Pigmentation on an 8-point Iris Transillumination Scale at 3 Months as Compared to Baseline. Participants Left and Right Eyes Will be Analyzed.Baseline and 3 months
High-resolution (2544x1696) digital images of the anterior segment of both eyes were captured prior to pupil dilation using diffuse illumination and iris transillumination. An independent reviewer selected two transillumination images from each eye of each participant for each visit according to preset quality criteria. Images were coded, randomized and presented to a panel of 18 graders on a SHARP 90" HD LED TV. After instruction and a practice dataset, graders scored each image using an 8-point scale. Graders could score images with a single decimal place if they felt an image fell in between two of the standards. The iris transillumination scale ranged from 0 to 8, with lower scores reflective of greater iris pigmentation (melanin content). The mean across all graders and the two images for each participant's eye at baseline and 3 months was calculated; these mean grades were then used to calculate absolute change from baseline at 3 months.
SecondaryAbsolute Mean Change in Iris Pigmentation on an 8-point Iris Transillumination Scale at 6 Months as Compared to Baseline. Participants Left and Right Eyes Will be Analyzed.Baseline and 6 months
High-resolution (2544x1696) digital images of the anterior segment of both eyes were captured prior to pupil dilation using diffuse illumination and iris transillumination. An independent reviewer selected two transillumination images from each eye of each participant for each visit according to preset quality criteria. Images were coded, randomized and presented to a panel of 18 graders on a SHARP 90" HD LED TV. After instruction and a practice dataset, graders scored each image using an 8-point scale. Graders could score images with a single decimal place if they felt an image fell in between two of the standards. The iris transillumination scale ranged from 0 to 8, with lower scores reflective of greater iris pigmentation (melanin content). The mean across all graders and the two images for each participant's eye at baseline and 6 months was calculated; these mean grades were then used to calculate absolute change from baseline at 6 months.
SecondaryAbsolute Mean Change in Iris Pigmentation on an 8-point Iris Transillumination Scale at 9 Months as Compared to Baseline. Participants Left and Right Eyes Will be Analyzed.Baseline and 9 months
High-resolution (2544x1696) digital images of the anterior segment of both eyes were captured prior to pupil dilation using diffuse illumination and iris transillumination. An independent reviewer selected two transillumination images from each eye of each participant for each visit according to preset quality criteria. Images were coded, randomized and presented to a panel of 18 graders on a SHARP 90" HD LED TV. After instruction and a practice dataset, graders scored each image using an 8-point scale. Graders could score images with a single decimal place if they felt an image fell in between two of the standards. The iris transillumination scale ranged from 0 to 8, with lower scores reflective of greater iris pigmentation (melanin content). The mean across all graders and the two images for each participant's eye at baseline and 9 months was calculated; these mean grades were then used to calculate absolute change from baseline at 9 months.
SecondaryAbsolute Change in Semi-quantitative Iris Pigmentation for Each Eye at 3 Months as Compared to BaselineBaseline and 3 months
In Adobe Photoshop 7.0 the high resolution slit lamp image was divided into 4 quadrants with vertical and horizontal lines transecting the center of the iris. Using the elliptical marquee tool, a circle, approximately 0.25 times the diameter of the iris, was drawn in the center of each quadrant. Gaussian blur with radius of 50 was applied to the area enclosed in the 4 circles. With the dropper tool, the red pigment value corresponding to the degree of iris transillumination was sampled at the center of each circle. The 4 values were averaged to yield a composite transillumination score for each subject. Quantified values were then correlated to a scale score from 1 to 8 to generate an 8-point iris transillumination scale, with lower scores reflective of greater iris pigmentation (melanin content). The mean score across the 2 images for each participant's eye was calculated at baseline and 3 months; these mean grades were then used to calculate absolute change from baseline.
SecondaryAbsolute Change in Semi-quantitative Iris Pigmentation for Each Eye at 6 Months as Compared to BaselineBaseline and 6 months
In Adobe Photoshop 7.0 the high resolution slit lamp image was divided into 4 quadrants with vertical and horizontal lines transecting the center of the iris. Using the elliptical marquee tool, a circle, approximately 0.25 times the diameter of the iris, was drawn in the center of each quadrant. Gaussian blur with radius of 50 was applied to the area enclosed in the 4 circles. With the dropper tool, the red pigment value corresponding to the degree of iris transillumination was sampled at the center of each circle. The 4 values were averaged to yield a composite transillumination score for each subject. Quantified values were then correlated to a scale score from 1 to 8 to generate an 8-point iris transillumination scale, with lower scores reflective of greater iris pigmentation (melanin content). The mean score across the 2 images for each participant's eye was calculated at baseline and 6 months; these mean grades were then used to calculate absolute change from baseline.
SecondaryAbsolute Change in Semi-quantitative Iris Pigmentation for Each Eye at 9 Months as Compared to BaselineBaseline and 9 months
In Adobe Photoshop 7.0 the high resolution slit lamp image was divided into 4 quadrants with vertical and horizontal lines transecting the center of the iris. Using the elliptical marquee tool, a circle, approximately 0.25 times the diameter of the iris, was drawn in the center of each quadrant. Gaussian blur with radius of 50 was applied to the area enclosed in the 4 circles. With the dropper tool, the red pigment value corresponding to the degree of iris transillumination was sampled at the center of each circle. The 4 values were averaged to yield a composite transillumination score for each subject. Quantified values were then correlated to a scale score from 1 to 8 to generate an 8-point iris transillumination scale, with lower scores reflective of greater iris pigmentation (melanin content). The mean score across the 2 images for each participant's eye was calculated at baseline and 9 months; these mean grades were then used to calculate absolute change from baseline.
SecondaryAbsolute Change in Semi-quantitative Iris Pigmentation for Each Eye at 12 Months as Compared to BaselineBaseline and 12 months
In Adobe Photoshop 7.0 the high resolution slit lamp image was divided into 4 quadrants with vertical and horizontal lines transecting the center of the iris. Using the elliptical marquee tool, a circle, approximately 0.25 times the diameter of the iris, was drawn in the center of each quadrant. Gaussian blur with radius of 50 was applied to the area enclosed in the 4 circles. With the dropper tool, the red pigment value corresponding to the degree of iris transillumination was sampled at the center of each circle. The 4 values were averaged to yield a composite transillumination score for each subject. Quantified values were then correlated to a scale score from 1 to 8 to generate an 8-point iris transillumination scale, with lower scores reflective of greater iris pigmentation (melanin content). The mean score across the 2 images for each participant's eye was calculated at baseline and 12 months; these mean grades were then used to calculate absolute change from baseline.
SecondaryPercent Change in Semi-quantitative Iris Pigmentation for Each Eye at 3 Months as Compared to BaselineBaseline and 3 months
In Adobe Photoshop 7.0 the high resolution slit lamp image was divided into 4 quadrants with vertical and horizontal lines transecting the center of the iris. Using the elliptical marquee tool, a circle, approximately 0.25 times the diameter of the iris, was drawn in the center of each quadrant. Gaussian blur with radius of 50 was applied to the area enclosed in the 4 circles. With the dropper tool, the red pigment value corresponding to the degree of iris transillumination was sampled at the center of each circle. The 4 values were averaged to yield a composite transillumination score for each subject. Quantified values were then correlated to a scale score from 1 to 8 to generate an 8-point iris transillumination scale, with lower scores reflective of greater iris pigmentation (melanin content). The mean score across the 2 images for each participant's eye was calculated at baseline and 3 months; these mean grades were then used to calculate percentage change from baseline.
SecondaryPercent Change in Semi-quantitative Iris Pigmentation for Each Eye at 6 Months as Compared to BaselineBaseline and 6 months
In Adobe Photoshop 7.0 the high resolution slit lamp image was divided into 4 quadrants with vertical and horizontal lines transecting the center of the iris. Using the elliptical marquee tool, a circle, approximately 0.25 times the diameter of the iris, was drawn in the center of each quadrant. Gaussian blur with radius of 50 was applied to the area enclosed in the 4 circles. With the dropper tool, the red pigment value corresponding to the degree of iris transillumination was sampled at the center of each circle. The 4 values were averaged to yield a composite transillumination score for each subject. Quantified values were then correlated to a scale score from 1 to 8 to generate an 8-point iris transillumination scale, with lower scores reflective of greater iris pigmentation (melanin content). The mean score across the 2 images for each participant's eye was calculated at baseline and 6 months; these mean grades were then used to calculate percentage change from baseline.

Outcomes65

Each outcome the trial posted results for, in ClinicalTrials.gov's words.

TypeOutcomeTime framePopulationUnitsMeasured as
PRIMARYAbsolute Mean Change in Iris Pigmentation on an 8-point Iris Transillumination Scale at 12 Months as Compared to Baseline. Participants Left and Right Eyes Will be Analyzed.Baseline and 12 monthsRight (OD) and left (OS) eyesscores on a scaleMEAN
SECONDARYAbsolute Mean Change in Iris Pigmentation on an 8-point Iris Transillumination Scale at 3 Months as Compared to Baseline. Participants Left and Right Eyes Will be Analyzed.Baseline and 3 monthsRight (OD) and left (OS) eyesscores on a scaleMEAN
SECONDARYAbsolute Mean Change in Iris Pigmentation on an 8-point Iris Transillumination Scale at 6 Months as Compared to Baseline. Participants Left and Right Eyes Will be Analyzed.Baseline and 6 monthsRight (OD) and left (OS) eyesscores on a scaleMEAN
SECONDARYAbsolute Mean Change in Iris Pigmentation on an 8-point Iris Transillumination Scale at 9 Months as Compared to Baseline. Participants Left and Right Eyes Will be Analyzed.Baseline and 9 monthsRight (OD) and left (OS) eyesscores on a scaleMEAN
SECONDARYAbsolute Change in Semi-quantitative Iris Pigmentation for Each Eye at 3 Months as Compared to BaselineBaseline and 3 monthsRight (OD) and left (OS) eyesscores on a scaleMEAN
SECONDARYAbsolute Change in Semi-quantitative Iris Pigmentation for Each Eye at 6 Months as Compared to BaselineBaseline and 6 monthsRight (OD) and left (OS) eyesscores on a scaleMEAN
SECONDARYAbsolute Change in Semi-quantitative Iris Pigmentation for Each Eye at 9 Months as Compared to BaselineBaseline and 9 monthsRight (OD) and left (OS) eyesscores on a scaleMEAN
SECONDARYAbsolute Change in Semi-quantitative Iris Pigmentation for Each Eye at 12 Months as Compared to BaselineBaseline and 12 monthsRight (OD) and left (OS) eyesscores on a scaleMEAN
SECONDARYPercent Change in Semi-quantitative Iris Pigmentation for Each Eye at 3 Months as Compared to BaselineBaseline and 3 monthsRight (OD) and left (OS) eyespercentage changeMEAN
SECONDARYPercent Change in Semi-quantitative Iris Pigmentation for Each Eye at 6 Months as Compared to BaselineBaseline and 6 monthsRight (OD) and left (OS) eyespercentage changeMEAN

Results by group210

Each measurement the trial posted, group by group, in the words and numbers it posted.

OutcomeGroupCategoryValueSpreadUnits
Absolute Mean Change in Iris Pigmentation on an 8-point Iris Transillumination Scale at 12 Months as Compared to Baseline. Participants Left and Right Eyes Will be Analyzed.NitisinoneOD1.2Standard Deviation 1.68scores on a scale
Absolute Mean Change in Iris Pigmentation on an 8-point Iris Transillumination Scale at 12 Months as Compared to Baseline. Participants Left and Right Eyes Will be Analyzed.NitisinoneOS0.9Standard Deviation 1.52scores on a scale
Absolute Mean Change in Iris Pigmentation on an 8-point Iris Transillumination Scale at 3 Months as Compared to Baseline. Participants Left and Right Eyes Will be Analyzed.NitisinoneOD0.8Standard Deviation 1.04scores on a scale
Absolute Mean Change in Iris Pigmentation on an 8-point Iris Transillumination Scale at 3 Months as Compared to Baseline. Participants Left and Right Eyes Will be Analyzed.NitisinoneOS0.9Standard Deviation 1.23scores on a scale
Absolute Mean Change in Iris Pigmentation on an 8-point Iris Transillumination Scale at 6 Months as Compared to Baseline. Participants Left and Right Eyes Will be Analyzed.NitisinoneOD0.6Standard Deviation 0.39scores on a scale
Absolute Mean Change in Iris Pigmentation on an 8-point Iris Transillumination Scale at 6 Months as Compared to Baseline. Participants Left and Right Eyes Will be Analyzed.NitisinoneOS0.4Standard Deviation 0.31scores on a scale
Absolute Mean Change in Iris Pigmentation on an 8-point Iris Transillumination Scale at 9 Months as Compared to Baseline. Participants Left and Right Eyes Will be Analyzed.NitisinoneOD0.9Standard Deviation 1.06scores on a scale
Absolute Mean Change in Iris Pigmentation on an 8-point Iris Transillumination Scale at 9 Months as Compared to Baseline. Participants Left and Right Eyes Will be Analyzed.NitisinoneOS0.6Standard Deviation 0.60scores on a scale
Absolute Change in Semi-quantitative Iris Pigmentation for Each Eye at 3 Months as Compared to BaselineNitisinoneOD1.2Standard Deviation 1.04scores on a scale
Absolute Change in Semi-quantitative Iris Pigmentation for Each Eye at 3 Months as Compared to BaselineNitisinoneOS0.6Standard Deviation 0.82scores on a scale

Participant flow3

How many started, completed or left each group, period by period.

PeriodMilestoneGroupParticipantsUnits counted
Overall StudySTARTEDNitisinone5
Overall StudyCOMPLETEDNitisinone5
Overall StudyNOT COMPLETEDNitisinone0

Adverse events10

Each adverse event the trial posted, group by group: the participants affected out of those at risk.

TypeEventOrgan systemGroupAffectedAt riskEvents
otherAnaemiaBlood and lymphatic system disordersNitisinone151
otherPalpitationsCardiac disordersNitisinone151
otherDizzinessGeneral disordersNitisinone151
otherDyspepsiaGastrointestinal disordersNitisinone151
otherPain in extremityMusculoskeletal and connective tissue disordersNitisinone151
otherGastrooesophageal reflux diseaseGastrointestinal disordersNitisinone151
otherHaemangiomaVascular disordersNitisinone151
otherNeurological examination abnormalInvestigationsNitisinone151
otherChest painCardiac disordersNitisinone151
otherBronchitisRespiratory, thoracic and mediastinal disordersNitisinone151

Adverse event totals3

The totals the trial posted for each group.

TotalGroupAffectedAt risk
Total, all-cause mortalityNitisinone05
Total, other adverse eventsNitisinone55
Total, serious adverse eventsNitisinone05

Papers4

The papers the trial lists on ClinicalTrials.gov.

PMIDListed asSource
1900309BACKGROUNDPubMed
1903591BACKGROUNDPubMed
15629289BACKGROUNDPubMed
30674731RESULTPubMed

Grants0

The grants NIH RePORTER links to the trial, newest funded first: NIH's, and some of AHRQ's, CDC's, FDA's and VA's. Each shows its title, principal investigators, organization and funder in its newest year.

None in this release.

Trial comparisons0

Comparisons of the trial's two groups, calculated by ConductScience from the counts it posted.

None in this release.

Tests0

The ConductCognition tests this trial's registered outcomes name, as ScienceGraph matched them in trial-tests-2026-11-12-0.2.1.

None in this release.

Data dates

The day each source was copied for this release.

ClinicalTrials.gov
2026-11-12
ClinicalTrials.gov
Results, from AACT
2026-03-23
AACT
NIH grant links
2026-11-13
NIH RePORTER

Sources 3

  • ClinicalTrials.gov's posted results, through CTTI's AACTFreely available. Acknowledgement requested
  • ClinicalTrials.govNo license stated
  • NIH RePORTER's clinical studies and project filesPublic domain
Each source's terms
  • ClinicalTrials.gov's posted results, through CTTI's AACTClinicalTrials.gov data via Aggregate Analysis of ClinicalTrials.gov (AACT), CTTI. CTTI makes its materials freely available and requests acknowledgement. https://aact.ctti-clinicaltrials.org/documentation/299
  • ClinicalTrials.govnone stated
  • NIH RePORTER's clinical studies and project filesPublic domain (NIH RePORTER)

ClinicalTrials.gov's data carry an international copyright outside the United States: https://clinicaltrials.gov/about-site/terms-conditions.

For software

Read this trial from software.

The record and each of its lists are JSON, twenty rows a page. No key.

GET https://conductscience.org/api/trials/v1/NCT01838655

GET https://conductscience.org/api/trials/v1/NCT01838655/registered?page=2