Trial

As registered on ClinicalTrials.gov, in the graph's capture of the registry.

Title
Safety and Effectiveness of the Orsiro Sirolimus Eluting Coronary Stent System in Subjects With Coronary Artery Lesions
NCT number
NCT02389946
Status
Completed
Phases
Not applicable
Enrollment
1,334 participants, actual
Lead sponsor
Biotronik, Inc.
Conditions
Coronary Artery Disease, Atherosclerosis, Coronary, Myocardial Ischemia, Ischemic Heart Disease, Acute Coronary Syndrome, Angina Pectoris
Interventions
Orsiro DES, Xience DES
First posted
2015-03-17
Last updated
2022-08-03
Results first posted
2019-08-01

Source ClinicalTrials.gov

Registered outcomes10

Each outcome the trial registered, primary first, in ClinicalTrials.gov's words.

ListOutcomeTime frameDescription
PrimaryPercentage of Participants With Target Lesion Failure (TLF) at 12 Months Post-Index Procedure by Bayesian Estimation12-MonthsTLF is defined as all cardiac death, target vessel Q-wave or non-Q-wave myocardial infarction (MI), or clinically driven target lesion revascularization (TLR).
SecondaryNumber of Lesions With Device SuccessHospital Discharge (6-24 hours post-index procedure)Defined as attainment of \< 30% residual stenosis of the target lesion using the assigned study stent only.
SecondaryNumber of Lesions With Lesion SuccessHospital Discharge (6-24 hours post-index procedure)Defined as attainment of \< 30% residual stenosis of the target lesion using any percutaneous method.
SecondaryNumber of Participants With Procedure SuccessHospital Discharge (6-24 hours post-index procedure)
Defined as attainment of \< 30% residual stenosis of the target lesion using the assigned study stent only without occurrence of in-hospital major adverse cardiac events (MACE; composite of all-cause death, Q-wave or non-Q-wave MI, and any clinically-driven TLR).
SecondaryNumber of Participants With Myocardial InfarctionHospital Discharge (6-24 hours post-index procedure), 1, 6, 12 months, 2, 3, 4 and 5 years
SecondaryNumber of Participants With Myocardial Infarction or Cardiac DeathHospital Discharge (6-24 hours post-index procedure), 1, 6, 12 months, 2, 3, 4 and 5 years
SecondaryNumber of Participants With MACE and Individual MACE ComponentsHospital Discharge (6-24 hours post-index procedure), 1, 6, 12 months, 2, 3, 4 and 5 years
MACE events are defined as all-cause death, Q-wave or non-Q-wave MI, or any clinically-driven TLR. The number of participants with any MACE event is provided, as well as number of participants with each of the individual components.
SecondaryNumber of Participants With TLF and Individual TLF ComponentsHospital Discharge (6-24 hours post-index procedure), 1, 6, 12 months, 2, 3, 4 and 5 years
TLF events are defined as cardiac death, target vessel Q-wave or non-Q-wave MI, or any clinically-driven TLR. The number of participants with any TLF event is provided, as well as number of participants with each of the individual components.
SecondaryNumber of Participants With Target Vessel Failure (TVF) and Individual TVF ComponentsHospital Discharge (6-24 hours post-index procedure), 1, 6, 12 months, 2, 3, 4 and 5 years
TVF events are defined as cardiac death, target vessel Q-wave or non-Q-wave MI, or any clinically-driven TVR. The number of participants with any TVF event is provided, as well as number of participants with each of the individual components.
SecondaryNumber of Participants With Stent Thrombosis24 hours, 30 days, 1 year, and 5 years post-index procedureStent thrombosis according to the Academic Research Consortium criteria.

Outcomes10

Each outcome the trial posted results for, in ClinicalTrials.gov's words.

TypeOutcomeTime framePopulationUnitsMeasured as
PRIMARYPercentage of Participants With Target Lesion Failure (TLF) at 12 Months Post-Index Procedure by Bayesian Estimation12-Months
Pre-specified Bayesian analysis: BIOFLOW-V intent-to-treat subjects who experienced the primary endpoint or had at least 330 days of follow-up and BIOFLOW-II (NCT01356888) and BIOFLOW-IV (NCT01939249) subjects who satisfied the BIOFLOW-V inclusion/exclusion criteria and experienced the primary endpoint or had at least 330 days of follow-up.
Percentage of participantsMEAN
SECONDARYNumber of Lesions With Device SuccessHospital Discharge (6-24 hours post-index procedure)Device Success per lesion. Lesions that were not treated and lesions missing both site-reported and core lab-assessed percent residual stenosis were excluded from the analysis.LesionsNUMBER
SECONDARYNumber of Lesions With Lesion SuccessHospital Discharge (6-24 hours post-index procedure)Lesion Success per lesion. Lesions that were not treated and lesions missing both site-reported and core lab-assessed percent residual stenosis were excluded from the analysis.LesionsCOUNT_OF_UNITS
SECONDARYNumber of Participants With Procedure SuccessHospital Discharge (6-24 hours post-index procedure)
Procedure success was analyzed per subject: for a subject to be considered a procedure success, all of the subject's target lesions had to be considered device success. Lesions that were not treated and lesions missing both site-reported and core lab-assessed percent residual stenosis were excluded from the analysis.
ParticipantsCOUNT_OF_PARTICIPANTS
SECONDARYNumber of Participants With Myocardial InfarctionHospital Discharge (6-24 hours post-index procedure), 1, 6, 12 months, 2, 3, 4 and 5 yearsAnalysis population for each outcome measure time frame is based on participants completing or experiencing an event at that time frame.ParticipantsCOUNT_OF_PARTICIPANTS
SECONDARYNumber of Participants With Myocardial Infarction or Cardiac DeathHospital Discharge (6-24 hours post-index procedure), 1, 6, 12 months, 2, 3, 4 and 5 yearsAnalysis population for each outcome measure time frame is based on participants completing or experiencing an event at that time frame.ParticipantsCOUNT_OF_PARTICIPANTS
SECONDARYNumber of Participants With MACE and Individual MACE ComponentsHospital Discharge (6-24 hours post-index procedure), 1, 6, 12 months, 2, 3, 4 and 5 yearsAnalysis population for each outcome measure time frame is based on participants completing or experiencing an event at that time frame.ParticipantsCOUNT_OF_PARTICIPANTS
SECONDARYNumber of Participants With TLF and Individual TLF ComponentsHospital Discharge (6-24 hours post-index procedure), 1, 6, 12 months, 2, 3, 4 and 5 yearsAnalysis population for each outcome measure time frame is based on participants completing or experiencing an event at that time frame.ParticipantsCOUNT_OF_PARTICIPANTS
SECONDARYNumber of Participants With Target Vessel Failure (TVF) and Individual TVF ComponentsHospital Discharge (6-24 hours post-index procedure), 1, 6, 12 months, 2, 3, 4 and 5 yearsAnalysis population for each outcome measure time frame is based on participants completing or experiencing an event at that time frame.ParticipantsCOUNT_OF_PARTICIPANTS
SECONDARYNumber of Participants With Stent Thrombosis24 hours, 30 days, 1 year, and 5 years post-index procedureAnalysis population for each outcome measure time frame is based on participants completing or experiencing an event at that time frame.ParticipantsCOUNT_OF_PARTICIPANTS

Results by group252

Each measurement the trial posted, group by group, in the words and numbers it posted.

OutcomeGroupCategoryValueSpreadUnits
Percentage of Participants With Target Lesion Failure (TLF) at 12 Months Post-Index Procedure by Bayesian EstimationOrsiro Sirolimus Coronary Stent System6.32Standard Deviation 0.75Percentage of participants
Percentage of Participants With Target Lesion Failure (TLF) at 12 Months Post-Index Procedure by Bayesian EstimationXience Everolimus Coronary Stent System8.90Standard Deviation 1.22Percentage of participants
Number of Lesions With Device SuccessOrsiro Sirolimus Coronary Stent System1082Lesions
Number of Lesions With Device SuccessXience Everolimus Coronary Stent System566Lesions
Number of Lesions With Lesion SuccessOrsiro Sirolimus Coronary Stent System1102Lesions
Number of Lesions With Lesion SuccessXience Everolimus Coronary Stent System579Lesions
Number of Participants With Procedure SuccessOrsiro Sirolimus Coronary Stent System827Participants
Number of Participants With Procedure SuccessXience Everolimus Coronary Stent System401Participants
Number of Participants With Myocardial InfarctionOrsiro Sirolimus Coronary Stent System6-24 hours post-index procedure34Participants
Number of Participants With Myocardial InfarctionXience Everolimus Coronary Stent System6-24 hours post-index procedure30Participants

Participant flow6

How many started, completed or left each group, period by period.

PeriodMilestoneGroupParticipantsUnits counted
Overall StudySTARTEDOrsiro Sirolimus Coronary Stent System884
Overall StudySTARTEDXience Everolimus Coronary Stent System450
Overall StudyCOMPLETEDOrsiro Sirolimus Coronary Stent System860
Overall StudyCOMPLETEDXience Everolimus Coronary Stent System435
Overall StudyNOT COMPLETEDOrsiro Sirolimus Coronary Stent System24
Overall StudyNOT COMPLETEDXience Everolimus Coronary Stent System15

Adverse events1,262

Each adverse event the trial posted, group by group: the participants affected out of those at risk.

TypeEventOrgan systemGroupAffectedAt riskEvents
otherAngina pectorisCardiac disordersOrsiro Sirolimus Coronary Stent System159884215
otherAngina pectorisCardiac disordersXience Everolimus Coronary Stent System94450125
otherNon-cardiac chest painGeneral disordersOrsiro Sirolimus Coronary Stent System163884240
otherNon-cardiac chest painGeneral disordersXience Everolimus Coronary Stent System89450128
otherMyocardial necrosis marker increasedInvestigationsOrsiro Sirolimus Coronary Stent System174884176
otherMyocardial necrosis marker increasedInvestigationsXience Everolimus Coronary Stent System9045091
otherDyspnoeaRespiratory, thoracic and mediastinal disordersOrsiro Sirolimus Coronary Stent System100884112
otherDyspnoeaRespiratory, thoracic and mediastinal disordersXience Everolimus Coronary Stent System4545052
otherAcute Myocardial InfarctionCardiac disordersOrsiro Sirolimus Coronary Stent System4988461
otherAcute Myocardial InfarctionCardiac disordersXience Everolimus Coronary Stent System2645035

Adverse event totals6

The totals the trial posted for each group.

TotalGroupAffectedAt risk
Total, all-cause mortalityOrsiro Sirolimus Coronary Stent System56884
Total, all-cause mortalityXience Everolimus Coronary Stent System27450
Total, other adverse eventsOrsiro Sirolimus Coronary Stent System291884
Total, other adverse eventsXience Everolimus Coronary Stent System165450
Total, serious adverse eventsOrsiro Sirolimus Coronary Stent System548884
Total, serious adverse eventsXience Everolimus Coronary Stent System293450

Papers13

The papers the trial lists on ClinicalTrials.gov.

PMIDListed asSource
28851504RESULTPubMed
29129253BACKGROUNDPubMed
30257191RESULTPubMed
30354631RESULTPubMed
30638888DERIVEDPubMed
31954661DERIVEDPubMed
32499026DERIVEDPubMed
32890442DERIVEDPubMed
32895004DERIVEDPubMed
34056911DERIVEDPubMed

1 to 10 of 13

See all 13 papers

Grants0

The grants NIH RePORTER links to the trial, newest funded first: NIH's, and some of AHRQ's, CDC's, FDA's and VA's. Each shows its title, principal investigators, organization and funder in its newest year.

None in this release.

Trial comparisons3

Comparisons of the trial's two groups, calculated by ConductScience from the counts it posted.

ComparisonSource
Orsiro Sirolimus Coronary Stent System vs Xience Everolimus Coronary Stent System: Number of Participants With Procedure SuccessTrial comparisons
Orsiro Sirolimus Coronary Stent System vs Xience Everolimus Coronary Stent System: deaths from any causeTrial comparisons
Orsiro Sirolimus Coronary Stent System vs Xience Everolimus Coronary Stent System: serious adverse eventsTrial comparisons

Tests0

The ConductCognition tests this trial's registered outcomes name, as ScienceGraph matched them in trial-tests-2026-11-12-0.2.1.

None in this release.

Data dates

The day each source was copied for this release.

ClinicalTrials.gov
2026-11-12
ClinicalTrials.gov
Results, from AACT
2026-03-23
AACT
NIH grant links
2026-11-13
NIH RePORTER

Sources 3

  • ClinicalTrials.gov's posted results, through CTTI's AACTFreely available. Acknowledgement requested
  • ClinicalTrials.govNo license stated
  • NIH RePORTER's clinical studies and project filesPublic domain
Each source's terms
  • ClinicalTrials.gov's posted results, through CTTI's AACTClinicalTrials.gov data via Aggregate Analysis of ClinicalTrials.gov (AACT), CTTI. CTTI makes its materials freely available and requests acknowledgement. https://aact.ctti-clinicaltrials.org/documentation/299
  • ClinicalTrials.govnone stated
  • NIH RePORTER's clinical studies and project filesPublic domain (NIH RePORTER)

ClinicalTrials.gov's data carry an international copyright outside the United States: https://clinicaltrials.gov/about-site/terms-conditions.

For software

Read this trial from software.

The record and each of its lists are JSON, twenty rows a page. No key.

GET https://conductscience.org/api/trials/v1/NCT02389946

GET https://conductscience.org/api/trials/v1/NCT02389946/results?page=2