Trial · NCT02611752
Registered outcomes11
Each outcome the trial registered, primary first, in ClinicalTrials.gov's words.
1 to 11 of 11
Download this page as JSON| List | Outcome | Time frame | Description |
|---|---|---|---|
| Primary | Treatment Phase Drug Liking Visual Analog Scale (VAS) Emax Scores for Baseline and Four Challenge Sessions Compared to Baseline (Completer Population) for CAM2038 q1w, 24 mg | 17 days | Treatment Phase Drug Liking Visual Analog Scale (VAS) item "At this moment, my liking of this drug is" for Baseline and Four Challenge sessions Compared to Baseline (Completer Population) for CAM2038 q1w, 24 mg, where values can range from 0 (strong disliking) to 100 (strong liking) and 50 is the neutral point. Higher scores mean worse outcome. |
| Primary | Treatment Phase Drug Liking Visual Analog Scale (VAS) Maximum Effect (Emax) Scores for Baseline and Four Challenge Sessions Compared to Baseline (Completer Population) for CAM2038 q1w, 32 mg | 17 days | Treatment Phase Drug Liking Visual Analog Scale (VAS) item "At this moment, my liking of this drug is" for Baseline and Four Challenge sessions Compared to Baseline (Completer Population), where values can range from 0 (strong disliking) to 100 (strong liking) and 50 is the neutral point. Higher scores mean worse outcome. |
| Primary | Inferential Analysis Results Drug Liking Visual Analog Scale (VAS) for Maximum Effect (Emax) Scores for Qualification/Baseline and Four Challenge Sessions (Completer Population) for CAM2038 q1w, 24 mg | 17 days | Inferential Analysis Results Drug Liking Visual Analog Scale (VAS) item "At this moment, my liking of this drug is" for Qualification/Baseline and Four Challenge sessions (Completer Population) for CAM2038 q1w, 24 mg, where values can range from 0 (strong disliking) to 100 (strong liking) and 50 is the neutral point. Higher scores mean worse outcome. |
| Primary | Inferential Analysis Results Drug Liking Visual Analog Scale (VAS) Maximum Effect (Emax) Scores for Qualification/Baseline and Four Challenge Sessions (Completer Population) for CAM2038 q1w, 32 mg | 17 days | Inferential Analysis Results Drug Liking Visual Analog Scale (VAS) item "At this moment, my liking of this drug is" for Qualification/Baseline and Four Challenge sessions (Completer Population) for CAM2038 q1w, 32 mg, where values can range from 0 (strong disliking) to 100 (strong liking) and 50 is the neutral point. Higher scores mean worse outcome. |
| Secondary | Inferential Analysis Results for Unipolar High Visual Analog Scale (VAS) for Maximum Effect (Emax) (Completer Population) | 15 days | Inferential Analysis Results for Unipolar High Visual Analog Scale (VAS) for Maximum Effect (Emax) (Completer Population) comparing hydromorphone challenge doses in each of the baseline and four challenge sequence with each other, presented as Least Squares (LS) Mean with Standard Error (SE) and 95% Confidence Interval (CI). VAS item "At this moment, I feel high" where values can range from 0 (Not at all High) to 100 (Extremely High). |
| Secondary | Inferential Analysis Results for Unipolar Good Drug Effects Visual Analog Scale (VAS) for Maximum Effect (Emax) (Completer Population) | 15 days | Inferential Analysis Results for Unipolar Good Drug Effects Visual Analog Scale (VAS) for Maximum Effect (Emax) (Completer Population) comparing hydromorphone challenge doses in each of the baseling and four challenge sequences with each other, presented as Least Squares (LS) Mean with Standard Error (SE) and 95% Confidence Interval (CI). VAS item "At this moment, I feel good drug effects" where values can range from 0 (Not at all ) to 100 (Extremely). |
| Secondary | Analysis of Treatment Phase Unipolar Bad Drug Effects Visual Analog Scale (VAS) for Maximum Effect (Emax) in 24 mg CAM2038 q1w Group (Completer Population) | 15 days | Analysis of Treatment Phase Unipolar Bad Drug Effects Visual Analog Scale (VAS) for Maximum Effect (Emax) in 24 mg CAM2038 q1w group (Completer Population) , presented as Least Squares (LS) mean with Standard Error (SE) for all 3 doses of hydromorphone in baseline and 4 Challenge Sessions. VAS item "At this moment, I feel bad effects" where values can range from 0 (Not at all) to 100 (Extremely). |
| Secondary | Analysis of Treatment Phase Unipolar Bad Drug Effects Visual Analog Scale (VAS) for Maximum Effect (Emax) in 32 mg CAM2038 q1w Group (Completer Population) | 15 days | Analysis of Treatment Phase Unipolar Bad Drug Effects Visual Analog Scale (VAS) for Maximum Effect (Emax) in 32 mg CAM2038 q1w group (Completer Population) , presented as Least Squares (LS) mean with Standard Error (SE) for all 3 doses of hydromorphone in baseline and 4 Challenge Sessions. VAS item "At this moment, I feel bad effects" where values can range from 0 (Not at all) to 100 (Extremely). |
| Secondary | Analysis Results for Unipolar Desire to Use Visual Analog Scale (VAS) for Maximum Effect (Emax) (Completer Population) | 15 days | Analysis Results for Desire to Use Visual Analog Scale (VAS) for Maximum Effect (Emax) (Completer Population) comparing hydromorphone challenge doses in each of the baseline and four challenge sequence with each other, presented as Least Squares (LS) Mean with Standard Error (SE) and 95% Confidence Interval (CI). VAS item "At this moment, I desire opiods" where values can range from 0 (Definitely not) to 100 (Definitely so). |
| Secondary | Analysis Results for Bipolar Alertness/Drowsiness Visual Analog Scale (VAS) for Maximum Effect (Emax) (Completer Population) | 15 days | Analysis Results for Bipolar Alertness/Drowsiness Visual Analog Scale (VAS) for Maximum Effect (Emax) (Completer Population) presented as Least Squares (LS) mean with Standard Error (SE) for all 3 doses of hydromorphone in baseline and 4 Challenge Sessions. VAS item "At this moment, my mental state is" where values can range from 0 (Very Drowsy) to 100 (Very alert), with 50 being neutral (Neither drowsy nor alert). |
| Secondary | Analysis Results for Unipolar Any Drug Effects Visual Analog Scale (VAS) for Maximum Effect (Emax) (Completer Population) | 15 days | Analysis Results for Unipolar Any Drug Effects Visual Analog Scale (VAS) for Maximum Effect (Emax) (Completer Population) presented as Least Squares (LS) mean with Standard Error (SE) for all 3 doses of hydromorphone in baseline and 4 Challenge Sessions. VAS item "At this moment, I fell any drug effects" where values can range from 0 (Not at all) to 100 (Extremely). |
Source ClinicalTrials.govtrials-2026-11-12-0.5.0
Sources 3
- ClinicalTrials.gov's posted results, through CTTI's AACTFreely available. Acknowledgement requested
- ClinicalTrials.govNo license stated
- NIH RePORTER's clinical studies and project filesPublic domain
Each source's terms
- ClinicalTrials.gov's posted results, through CTTI's AACTClinicalTrials.gov data via Aggregate Analysis of ClinicalTrials.gov (AACT), CTTI. CTTI makes its materials freely available and requests acknowledgement. https://aact.ctti-clinicaltrials.org/documentation/299
- ClinicalTrials.govnone stated
- NIH RePORTER's clinical studies and project filesPublic domain (NIH RePORTER)
ClinicalTrials.gov's data carry an international copyright outside the United States: https://clinicaltrials.gov/about-site/terms-conditions.
For software
Read this list from software.
Twenty rows a page, as JSON. No key.
GET https://conductscience.org/api/trials/v1/NCT02611752/registered