Trial · NCT05257291
Registered outcomes14
Each outcome the trial registered, primary first, in ClinicalTrials.gov's words.
1 to 14 of 14
Download this page as JSON| List | Outcome | Time frame | Description |
|---|---|---|---|
| Primary | Blood pressure. | Baseline. | Value of ambulatory blood pressure obtained from the mean of three different misurations. |
| Primary | Heart rate. | Baseline. | Ambulatory recorder of the heart rate of the patient. |
| Primary | Endothelial parameters. | Baseline. | PAT signals were obtained using the EndoPAT-2000 device, which has been vali-dated and used previously to assess peripheral arterial tone in other populations. Endothelial function is measured via a reactive hyper-emia (RH) protocol: it consists of a 5 minutes baseline mea-surement, after which a blood pressure cuff on the test arm isinflated to 60 mm Hg above baseline systolic BP or at least200 mm Hg for 5 minutes. After 5 minutes, the cuff is deflated, and the PAT tracing isrecorded for a further 5 minutes. The cal-culated ratio is called RH-PAT index or RH index (RHI). |
| Primary | Arterial stiffness parameters. | Baseline. | The radial artery waveform was recorded using the SphygmoCor system. The tip of the tonometer was pressed gently against the radial artery at the site of maximum pulsation at the wrist. This micromanometer precisely records pressure within the artery. he augmentation pressure is defined as the height of the late systolic peak above the inflection point. Augmentation index is expressed as a percentage of PPAO. Augmentation index is a measure of the stiffness of the arterial walls, namely pulsatile load. Because there is a linear relationship between it and heart rate (HR), augmentation index was standardized to a HR of 75 bpm (AIx@75). |
| Primary | Echocardiographic parameters. | Baseline. | Bi-dimensional transthoracic echocardiographic examinations were performed using Vivid 9 and Vivid Q (GE Medical HealthCare, USA) with a probe of 3.5 MHz, to assess LV dimensions and systolic function, according to the guidelines. The main points were: the dimensions of atria and ventricles, stenosis and valve insufficiencies, systolic and diastolic function VS and VD, Dimensions and elastic properties of the ascending aorta (compliance, distensibility, stiffness index, elastic modulus of Peterson, PWV, M-mode strain, tissue strain). |
| Primary | Plasmatic melatonin levels. | Baseline. | Obtained with ELISA laboratory test. |
| Primary | Total circulating antioxidant capacity in plasma. | Baseline. | Obtained with ELISA laboratory test. |
| Primary | Blood pressure. | 1 year. | Ambulatory blood pressure obtained from the mean of three different misurations. |
| Primary | Heart rate. | 1 year. | Ambulatory recorder of the heart rate of the patient. |
| Primary | Endothelial parameters. | 1 year. | PAT signals were obtained using the EndoPAT-2000 device, which has been vali-dated and used previously to assess peripheral arterial tone in other populations. Endothelial function is measured via a reactive hyper-emia (RH) protocol: it consists of a 5 minutes baseline mea-surement, after which a blood pressure cuff on the test arm isinflated to 60 mm Hg above baseline systolic BP or at least200 mm Hg for 5 minutes. After 5 minutes, the cuff is deflated, and the PAT tracing isrecorded for a further 5 minutes. The cal-culated ratio is called RH-PAT index or RH index (RHI). |
| Primary | Arterial stiffness parameters. | 1 year. | The radial artery waveform was recorded using the SphygmoCor system. The tip of the tonometer was pressed gently against the radial artery at the site of maximum pulsation at the wrist. This micromanometer precisely records pressure within the artery. he augmentation pressure is defined as the height of the late systolic peak above the inflection point. Augmentation index is expressed as a percentage of PPAO. Augmentation index is a measure of the stiffness of the arterial walls, namely pulsatile load. Because there is a linear relationship between it and heart rate (HR), augmentation index was standardized to a HR of 75 bpm (AIx@75). |
| Primary | Echocardiographic parameters. | 1 year. | Bi-dimensional transthoracic echocardiographic examinations were performed using Vivid 9 and Vivid Q (GE Medical HealthCare, USA) with a probe of 3.5 MHz, to assess LV dimensions and systolic function, according to the guidelines. The main points were: the dimensions of atria and ventricles, stenosis and valve insufficiencies, systolic and diastolic function VS and VD, Dimensions and elastic properties of the ascending aorta (compliance, distensibility, stiffness index, elastic modulus of Peterson, PWV, M-mode strain, tissue strain). |
| Primary | Plasmatic melatonin levels. | 1 year. | Obtained with ELISA laboratory test. |
| Primary | Total circulating antioxidant capacity in plasma. | 1 year. | Obtained with ELISA laboratory test. |
Source ClinicalTrials.govtrials-2026-11-12-0.5.0
Sources 3
- ClinicalTrials.gov's posted results, through CTTI's AACTFreely available. Acknowledgement requested
- ClinicalTrials.govNo license stated
- NIH RePORTER's clinical studies and project filesPublic domain
Each source's terms
- ClinicalTrials.gov's posted results, through CTTI's AACTClinicalTrials.gov data via Aggregate Analysis of ClinicalTrials.gov (AACT), CTTI. CTTI makes its materials freely available and requests acknowledgement. https://aact.ctti-clinicaltrials.org/documentation/299
- ClinicalTrials.govnone stated
- NIH RePORTER's clinical studies and project filesPublic domain (NIH RePORTER)
ClinicalTrials.gov's data carry an international copyright outside the United States: https://clinicaltrials.gov/about-site/terms-conditions.
For software
Read this list from software.
Twenty rows a page, as JSON. No key.
GET https://conductscience.org/api/trials/v1/NCT05257291/registered