ConductScience.org, home

Trial · NCT06544434

Laser Acupuncture for Meniere Disease

NCT06544434, Phase 2, Unknown, Beijing Tongren Hospital

3 sourcestrials-2026-11-12-0.5.0

Download JSON
Cite this record

ConductScience Library. Laser Acupuncture for Meniere Disease. Trials, record NCT06544434. Release trials-2026-11-12-0.5.0, 12 Nov 2026. https://conductscience.org/library/trials/NCT06544434

On this page

Trial

As registered on ClinicalTrials.gov, in the graph's capture of the registry.

Title
Laser Acupuncture for Meniere Disease
NCT number
NCT06544434
Status
Unknown
Phases
Phase 2
Enrollment
324 participants, estimated
Lead sponsor
Beijing Tongren Hospital
Conditions
Meniere Disease
Interventions
Multiwave Locked System (MLS) laser (Mphi laser, ASA Srl, Vicenza, Italy), Betahistine Mesylate tablet
First posted
2024-08-09
Last updated
2024-08-09

Source ClinicalTrials.gov

Registered outcomes6

Each outcome the trial registered, primary first, in ClinicalTrials.gov's words.

ListOutcomeTime frameDescription
PrimaryDizziness Handicap Inventory (DHI)Baseline, month 3, 6 and 12
The DHI is 25-items self-reported questionnaire that used to evaluate the functional, emotional, and physical impact of dizziness on patients' daily life. Among the overall 25 items of questions, 9 items are emotional related, 9 items are functional related, and 7 items are physical related questions. The three answer options are "yes," "sometimes," and "no," with scores of 4, 2, and 0, respectively. The overall score is the sum of 25 items (Range: 0-100). Higher scores equate to greater severity of dizziness symptoms.
PrimaryTinnitus Handicap Inventory (THI)Baseline, month 3, 6 and 12
The THI is a 25-items, self-reported questionnaire regarding tinnitus handicap in daily life. The questionnaire comprises a 12-item functional subscale, an 8-item emotional subscale, and a 5-item catastrophic subscale. The three answer options are "yes," "sometimes," and "no," with scores of 4, 2, and 0, respectively. The overall score is the sum of 25 items (Range: 0-100). Higher scores equate to greater severity of tinnitus symptoms.
PrimaryPure tone thresholds (PTA)Baseline, month 3, 6 and 12
The pure tone thresholds was performed in a sound-attenuated, double-walled booth with circumaural headphones (Sennheiser HD 280 for frequencies from 250 to 8000 Hz and Sennheiser HD 200 for frequencies from 8000 to 14000 Hz; Sennheiser, Old Lyme, USA) on a certified and calibrated audiometric system (Interacoustics, Middelfart, Denmark). Thresholds were measured using a probe-detection paradigm with pure tones presented for 250 ms at frequencies of 250, 500, 1000, 2000, 4000, 8000 Hz for each ear. To determine the LDL, the volume was set to 75 dB at 1000 Hz and then continuously raised in 5 dB steps (every 5 s) until the subject gave the signal that this volume was uncomfortable. When the volume exceeded 110 dB the test was stopped to prevent any hearing damage. The severity of hearing impairment was calculated as mild (20-40 dB), moderate (41-70 dB), severe (71-95 dB) and profound (\>95 dB). Normal hearing was defined as pure-tone thresholds less than 20 dB.
PrimaryVisual analogue scale (VAS)Baseline, month 3, 6 and 12
The VAS scale of aural fullness consists of a 100 mm straight line with defined endpoints ("no aural fullness" and "worst aural fullness imaginable") on which the patients were asked to mark their experienced aural fullness (results in mm) at the actual time ("VAS now"). The higher VAS score (Range: 0-100) is correlated with a severe aural fullness.
SecondaryVideo head impulse test (vHIT)Baseline, month 3, 6 and 12
vHIT was used to assess the function of all the six SCCs by measuring the gain of the vestibulo-ocular reflex. The instrument comprises an inertial measurement unit to measure movements of the head and an infrared camera to record eye movements. vHIT can calculate the mean gain value (ratio of eye to head velocity) for each of the six SCCs, and also detect covert or overt saccades. During the test, goggles were secured firmly to patients' head to ensure that the goggles did not slip from the face during head movement. Patients sat \~1.5 m in front of a wall on which a visual target was affixed. Before testing, head movement and eye movement were calibrated according to the manufacturer's instructions. According to manufacture recommendations, normal gain values are expected to range between 0.80 and 1.20 for horizontal canals, and 0.70-1.20 for vertical canals. Pathological saccades and gain values below the normal range were recorded.
SecondaryThe Caloric TestBaseline, month 3, 6 and 12
The caloric test was employed to evaluate the horizontal semicircular canal (SCC). The patients took supine position and raised their head to 30 degrees with a pillow. The right and left ears of the patients were stimulated with cool air (24°C) and warm air (50°C) by using an air caloric irrigator system (Micromedical Technologies Inc., Chatham, IL, USA) and a Brookler-Grams closed-loop irrigation unit. We used videonystagmography (VNG) (Ulmer Inc. Marseille, France) to record horizontal eye movements during the test. The subjects were perfused four times for 60 s. After perfusion, the nystagmus was observed for 60 s. Unilateral Weakness (UW) was calculated using the maximal slow phase eye velocity: UW = \| (RC + RW) - (LC + LW) \| / (RC + RW +LC + LW) × 100%, where RC = right cool, RW = right warm, LC = left cool, and LW = left warm. UW \>25% was considered abnormal.

Outcomes0

Each outcome the trial posted results for, in ClinicalTrials.gov's words.

None in this release.

Results by group0

Each measurement the trial posted, group by group, in the words and numbers it posted.

None in this release.

Participant flow0

How many started, completed or left each group, period by period.

None in this release.

Adverse events0

Each adverse event the trial posted, group by group: the participants affected out of those at risk.

None in this release.

Adverse event totals0

The totals the trial posted for each group.

None in this release.

Papers0

The papers the trial lists on ClinicalTrials.gov.

None in this release.

Grants0

The grants NIH RePORTER links to the trial, newest funded first: NIH's, and some of AHRQ's, CDC's, FDA's and VA's. Each shows its title, principal investigators, organization and funder in its newest year.

None in this release.

Trial comparisons0

Comparisons of the trial's two groups, calculated by ConductScience from the counts it posted.

None in this release.

Tests0

The ConductCognition tests this trial's registered outcomes name, as ScienceGraph matched them in trial-tests-2026-11-12-0.2.1.

None in this release.

Data dates

The day each source was copied for this release.

ClinicalTrials.gov
2026-11-12
ClinicalTrials.gov
Results, from AACT
2026-03-23
AACT
NIH grant links
2026-11-13
NIH RePORTER

Sources 3

  • ClinicalTrials.gov's posted results, through CTTI's AACTFreely available. Acknowledgement requested
  • ClinicalTrials.govNo license stated
  • NIH RePORTER's clinical studies and project filesPublic domain
Each source's terms
  • ClinicalTrials.gov's posted results, through CTTI's AACTClinicalTrials.gov data via Aggregate Analysis of ClinicalTrials.gov (AACT), CTTI. CTTI makes its materials freely available and requests acknowledgement. https://aact.ctti-clinicaltrials.org/documentation/299
  • ClinicalTrials.govnone stated
  • NIH RePORTER's clinical studies and project filesPublic domain (NIH RePORTER)

ClinicalTrials.gov's data carry an international copyright outside the United States: https://clinicaltrials.gov/about-site/terms-conditions.

For software

Read this trial from software.

The record and each of its lists are JSON, twenty rows a page. No key.

GET https://conductscience.org/api/trials/v1/NCT06544434

GET https://conductscience.org/api/trials/v1/NCT06544434/registered