Trial · NCT07897318
Registered outcomes15
Each outcome the trial registered, primary first, in ClinicalTrials.gov's words.
1 to 15 of 15
Download this page as JSON| List | Outcome | Time frame | Description |
|---|---|---|---|
| Primary | Word Test in Quiet | Pre-op to 6 months after first fitting | Word recognition in quiet, on a scale from 0 to 100% correct, higher scores indicate better outcomes |
| Primary | Sentence Test in Noise | Pre-op to 6 months after first fitting | Oldenburg Matrix Test, results measured in dB signal-to-noise ratio (SNR) with a range of +30 to -10 dB SNR, lower values indicating better outcomes |
| Secondary | Health Utility Index Mark 3 (HUI3) | Pre-op to 6 months after first fitting | Health utility scale: 1.00: Perfect health. 0.00: Death. Negative values: States worse than death. |
| Secondary | Nijmegen Cochlear Implant Questionnaire (NCIQ) | Pre-op to 6 months after first fitting | Disease specific Quality of Life, overall score is on a scale from 0 to 100, higher numbers indicating better outcomes |
| Secondary | Change in body sound perception | through study completion, an average of 12 months after first fitting | Participant reported scale on body sound perception (0 - no disturbance to 10 - very disturbing) |
| Secondary | Change in stigma perception | through study completion, an average of 12 months after first fitting | Participant reported scale on stigma perception (0 - no stigmatization to 10 - strong stigmatization) |
| Secondary | Change in comfort perception | through study completion, an average of 12 months after first fitting | Participant reported scale on stigma perception (0 - not comfortable to 10 - very comfortable) |
| Other | Word test in quiet | through study completion, an average of 12 months after first fitting | Word recognition in quiet, on a scale from 0 to 100% correct, higher scores indicate better outcomes |
| Other | Sentence Test in Noise | through study completion, an average of 12 months after first fitting | Oldenburg Matrix Test, results measured in dB signal-to-noise ratio (SNR) with a range of +30 to -10 dB SNR, lower values indicating better outcomes |
| Other | Health Utility Index Mark 3 (HUI3) | through study completion, an average of 12 months after first fitting | Health utility scale: 1.00: Perfect health. 0.00: Death. Negative values: States worse than death. |
| Other | Nijmegen Cochlear Implant Questionnaire (NCIQ) | through study completion, an average of 12 months after first fitting | Disease specific Quality of Life, overall score is on a scale from 0 to 100, higher numbers indicating better outcomes |
| Other | Speech, Spatial, Quality of Hearing (SSQ12) | through study completion, an average of 12 months after first fitting | Speech, Spatial and Quality of hearing scale from 0 to 10, higher numbers indicating better outcomes |
| Other | Hearing Implant Sound Quality Index (HISQUI) | through study completion, an average of 12 months after first fitting | Sound quality score ranging from 19 (very poor sound quality) to 133 (very good sound quality) |
| Other | Tinnitus Functional Index (TFI) | through study completion, an average of 12 months after first fitting | Tinnitus questionnaire measures the severity and negative impact of tinnitus on a 0 (Not a Problem / Slight Tinnitus) to 100 (Very Big Problem / Very Severe Tinnitus) scale |
| Other | Audiogram | through study completion, an average of 12 months after first fitting | Pure-tone air-conduction hearing thresholds will be measured in each ear. The threshold is the lowest sound level, in decibels hearing level (dB HL), at which the participant responds. The outcome is the threshold at each frequency. Higher thresholds mean poorer hearing; lower thresholds better hearing. |
Source ClinicalTrials.govtrials-2026-11-12-0.5.0
Sources 3
- ClinicalTrials.gov's posted results, through CTTI's AACTFreely available. Acknowledgement requested
- ClinicalTrials.govNo license stated
- NIH RePORTER's clinical studies and project filesPublic domain
Each source's terms
- ClinicalTrials.gov's posted results, through CTTI's AACTClinicalTrials.gov data via Aggregate Analysis of ClinicalTrials.gov (AACT), CTTI. CTTI makes its materials freely available and requests acknowledgement. https://aact.ctti-clinicaltrials.org/documentation/299
- ClinicalTrials.govnone stated
- NIH RePORTER's clinical studies and project filesPublic domain (NIH RePORTER)
ClinicalTrials.gov's data carry an international copyright outside the United States: https://clinicaltrials.gov/about-site/terms-conditions.
For software
Read this list from software.
Twenty rows a page, as JSON. No key.
GET https://conductscience.org/api/trials/v1/NCT07897318/registered