ConductScience.org, home

Trial · NCT07902414

Registered outcomes11

Each outcome the trial registered, primary first, in ClinicalTrials.gov's words.

ListOutcomeTime frameDescription
PrimaryWord Test in QuietPre-op to 36 months after first fittingWord recognition in quiet, on a scale from 0 to 100% correct, higher scores indicate better outcomes
SecondaryNijmegen Cochlear Implant Questionnaire (NCIQ)Pre-op to 36 months after first fittingDisease specific Quality of Life, overall score is on a scale from 0 to 100, higher numbers indicating better outcomes
SecondarySpeech, Spatial, Quality of Hearing (SSQ12)Pre-op to 36 months after first fittingSpeech, Spatial and Quality of hearing scale from 0 to 10, higher numbers indicating better outcomes
OtherWord test in quietthrough study completion, an average of 60 months after first fittingWord recognition in quiet, on a scale from 0 to 100% correct, higher scores indicate better outcomes
OtherSentence Test in Noisethrough study completion, an average of 60 months after first fittingOldenburg Matrix Test, results measured in dB signal-to-noise ratio (SNR) with a range of +30 to -10 dB SNR, lower values indicating better outcomes
OtherHealth Utility Index Mark 3 (HUI3)through study completion, an average of 60 months after first fittingHealth utility scale: 1.00: Perfect health. 0.00: Death. Negative values: States worse than death.
OtherNijmegen Cochlear Implant Questionnaire (NCIQ)through study completion, an average of 60 months after first fittingDisease specific Quality of Life, overall score is on a scale from 0 to 100, higher numbers indicating better outcomes
OtherSpeech, Spatial, Quality of Hearing (SSQ12)through study completion, an average of 60 months after first fittingSpeech, Spatial and Quality of hearing scale from 0 to 10, higher numbers indicating better outcomes
OtherHearing Implant Sound Quality Index (HISQUI)through study completion, an average of 60 months after first fittingSound quality score ranging from 19 (very poor sound quality) to 133 (very good sound quality)
OtherTinnitus functional index (TFI)through study completion, an average of 60 months after first fittingTinnitus questionnaire measures the severity and negative impact of tinnitus on a 0 (Not a Problem / Slight Tinnitus) to 100 (Very Big Problem / Very Severe Tinnitus) scale
OtherAudiogramthrough study completion, an average of 60 months after first fitting
Pure-tone air-conduction hearing thresholds will be measured in each ear. The threshold is the lowest sound level, in decibels hearing level (dB HL), at which the participant responds. The outcome is the threshold at each frequency. Higher thresholds mean poorer hearing; lower thresholds better hearing.

Source ClinicalTrials.govtrials-2026-11-12-0.5.0

Sources 3

  • ClinicalTrials.gov's posted results, through CTTI's AACTFreely available. Acknowledgement requested
  • ClinicalTrials.govNo license stated
  • NIH RePORTER's clinical studies and project filesPublic domain
Each source's terms
  • ClinicalTrials.gov's posted results, through CTTI's AACTClinicalTrials.gov data via Aggregate Analysis of ClinicalTrials.gov (AACT), CTTI. CTTI makes its materials freely available and requests acknowledgement. https://aact.ctti-clinicaltrials.org/documentation/299
  • ClinicalTrials.govnone stated
  • NIH RePORTER's clinical studies and project filesPublic domain (NIH RePORTER)

ClinicalTrials.gov's data carry an international copyright outside the United States: https://clinicaltrials.gov/about-site/terms-conditions.

For software

Read this list from software.

Twenty rows a page, as JSON. No key.

GET https://conductscience.org/api/trials/v1/NCT07902414/registered