ConductScience.org, home

Library / Trials

Compression-Only Versus Standard Basic Life Support Training in Nursing Students

NCT07915778, Not applicable, Not yet recruiting, Universitat Internacional de Catalunya

Trial 10

As registered on ClinicalTrials.gov, in the graph's capture of the registry.

FieldValueSource
TitleCompression-Only Versus Standard Basic Life Support Training in Nursing StudentsClinicalTrials.gov
NCT numberNCT07915778ClinicalTrials.gov
StatusNot yet recruitingClinicalTrials.gov
PhasesNot applicableClinicalTrials.gov
Enrollment104 participants, estimatedClinicalTrials.gov
Lead sponsorUniversitat Internacional de CatalunyaClinicalTrials.gov
ConditionsCardiopulmonary Resuscitation, Out-of-Hospital Cardiac ArrestClinicalTrials.gov
InterventionsBLS and AED Training With Rescue Breaths, BLS and AED Training Without Rescue BreathsClinicalTrials.gov
First posted2026-11-04ClinicalTrials.gov
Last updated2026-11-04ClinicalTrials.gov

Registered outcomes 33

Each outcome the trial registered, primary first, in ClinicalTrials.gov's words.

ListOutcomeTime frameDescriptionSource
PrimaryTheoretical-Practical Competence Level in Basic Life Support (BLS) and Automated External Defibrillator (AED) After TrainingImmediately after training (same day as training)
Composite competence score (range 0-10; higher scores indicate better competence), calculated as the mean of three components, each expressed on a 0-10 scale: (1) final theoretical test (10 multiple-choice questions from the Catalan Resuscitation Council); (2) overall CPR quality recorded by the Resusci Anne QCPR manikin with SkillReporter software (mean of the four 2-minute cycles of the 8-minute simulation); and (3) practical BLS and AED skills rated by the instructor with the CORVAL rubric.
ClinicalTrials.gov
PrimaryRetention of Theoretical-Practical Competence in BLS and AED4 months after trainingSame composite competence score (range 0-10; higher scores indicate better competence) obtained by repeating the theoretical test and the simulated practical assessment 4 months after training.ClinicalTrials.gov
SecondaryTheoretical Knowledge of the BLS and AED AlgorithmImmediately after training and 4 months after trainingScore on the final theoretical test of 10 multiple-choice questions from the Catalan Resuscitation Council (one point per correct answer; range 0-10; higher scores indicate better knowledge).ClinicalTrials.gov
SecondaryOverall CPR Quality Score Recorded by SkillReporter SoftwareAt 2, 4, 6 and 8 minutes of the simulated CPR immediately after training, and 4 months after training
Overall CPR performance score (percentage, range 0-100%; higher values indicate better quality) calculated by the SkillReporter software from the Resusci Anne QCPR manikin, based on chest compression quality and, in the control group, rescue breath quality.
ClinicalTrials.gov
SecondaryChest Compression QualityAt 2, 4, 6 and 8 minutes of the simulated CPR immediately after training, and 4 months after training
Percentage of correctly performed chest compressions (range 0-100%) recorded by the SkillReporter software, based on compression depth, compression rate, full chest recoil, number of compressions and hand position.
ClinicalTrials.gov
SecondaryPractical BLS and AED SkillsImmediately after training and 4 months after trainingScore on the CORVAL practical assessment rubric completed by the instructor (items rated 0, 1 or 2; total transformed to a 0-10 scale; higher scores indicate better performance).ClinicalTrials.gov
SecondaryChange in Muscular Fatigue Measured With a Dynamometer From Before to After the 8-Minute Simulated CPRImmediately before and immediately after the 8-minute simulated CPR on the day of training
Decrease in the functional capacity of the specific muscle groups involved in CPR (protocol variable V6), measured with a dynamometer with recording software: sustained 20-second contraction of a hand-held pneumatic bulb. The software records the force curve in real time (not visible to the participant) to identify a decrease in force, neuromuscular irregularities and changes in the stability of the effort. The test is performed before and after the simulation to compare the participant's muscular state. Reported as the change from the value before the simulation (baseline) to the value after the simulation.
ClinicalTrials.gov
SecondaryChange in Heart Rate From Before to After the 8-Minute Simulated CPRBefore the simulation, continuously throughout the simulated CPR, and immediately after the simulation on the day of training
Heart rate (beats per minute) measured with an arm heart rate monitor and a blood pressure monitor. Reported as the change from the value before the simulation (baseline) to the value after the simulation.
ClinicalTrials.gov
SecondaryChange in Systolic, Diastolic and Mean Arterial Blood Pressure From Before to After the 8-Minute Simulated CPRBefore and within 60 seconds after the 8-minute simulated CPR on the day of training
Systolic, diastolic and mean arterial blood pressure (mmHg) measured with a validated blood pressure monitor, at rest in a seated position before the simulation and within 60 seconds after finishing CPR, using the same arm, device and cuff size. Reported as the change from the value before the simulation (baseline) to the value after the simulation.
ClinicalTrials.gov
SecondaryChange in Perceived Exertion Measured With the Modified Borg Scale From Before to After the 8-Minute Simulated CPRImmediately before and immediately after the 8-minute simulated CPR on the day of training
Perceived physical exertion measured with the modified Borg scale (range 0-10; higher scores indicate greater perceived exertion). Reported as the change from the value before the simulation (baseline) to the value after the simulation.
ClinicalTrials.gov
SecondaryParticipant Satisfaction With the Training Measured With a Likert-Scale Satisfaction SurveyAfter the 8-minute simulated CPR on the day of training
Satisfaction with the content, methodology, organisation and perceived usefulness of the training, measured with a satisfaction survey using a Likert scale (range 0-5; 0 = very dissatisfied, 5 = very satisfied).
ClinicalTrials.gov
SecondarySelf-Perceived Knowledge of BLS and AED Measured With an Ad Hoc QuestionnaireBefore training, after the 8-minute simulated CPR on the day of training, and 4 months after trainingSelf-perceived knowledge of BLS and AED measured with an ad hoc questionnaire (range 0-10; 0 = none, 10 = excellent).ClinicalTrials.gov
SecondaryDuration of CPR per CycleAt 2, 4, 6 and 8 minutes of the simulated CPR immediately after training, and 4 months after trainingDuration of CPR in each cycle (minutes), recorded by the SkillReporter software. In this study, this variable is constant: 2 minutes per cycle (protocol variable V2.4).ClinicalTrials.gov
SecondaryCorrect Hand Position During Chest CompressionsAt 2, 4, 6 and 8 minutes of the simulated CPR immediately after training, and 4 months after trainingPercentage of chest compressions with correct hand position in the centre of the chest (range 0-100%), recorded by the SkillReporter software (protocol variable V2.7).ClinicalTrials.gov
SecondaryMean Chest Compression DepthAt 2, 4, 6 and 8 minutes of the simulated CPR immediately after training, and 4 months after trainingMean depth of all chest compressions (mm), recorded by the SkillReporter software (protocol variable V2.9).ClinicalTrials.gov
SecondaryChest Compressions With Full Chest RecoilAt 2, 4, 6 and 8 minutes of the simulated CPR immediately after training, and 4 months after trainingPercentage of chest compressions with full chest recoil (range 0-100%), recorded by the SkillReporter software (protocol variable V2.10).ClinicalTrials.gov
SecondaryChest Compressions With Adequate DepthAt 2, 4, 6 and 8 minutes of the simulated CPR immediately after training, and 4 months after trainingPercentage of chest compressions with adequate depth of 5-6 cm (range 0-100%), recorded by the SkillReporter software (protocol variable V2.11).ClinicalTrials.gov
SecondaryChest Compressions at Correct RateAt 2, 4, 6 and 8 minutes of the simulated CPR immediately after training, and 4 months after trainingPercentage of chest compressions performed at a correct rate of 100-120 compressions per minute (range 0-100%), recorded by the SkillReporter software (protocol variable V2.12).ClinicalTrials.gov
SecondaryChest Compression RateAt 2, 4, 6 and 8 minutes of the simulated CPR immediately after training, and 4 months after trainingNumber of chest compressions per minute, recorded by the SkillReporter software (protocol variable V2.13).ClinicalTrials.gov
SecondaryPercentage of Participants Competent in BLS and AED (Competence Level of 7 or Higher Out of 10)Immediately after training and 4 months after training
Proportion of participants demonstrating an adequate level of competence in performing the BLS and AED algorithm (yes/no), determined from the competence level (protocol variable V4): participants with a competence level of 7 or higher out of 10 are considered competent (protocol variable V5).
ClinicalTrials.gov

Outcomes 0

Each outcome the trial posted results for, in ClinicalTrials.gov's words.

TypeOutcomeTime framePopulationUnitsMeasured asSource

Results by group 0

Each measurement the trial posted, group by group, in the words and numbers it posted.

OutcomeGroupCategoryValueSpreadUnitsSource

Participant flow 0

How many started, completed or left each group, period by period.

PeriodMilestoneGroupParticipantsUnits countedSource

Adverse events 0

Each adverse event the trial posted, group by group: the participants affected out of those at risk.

TypeEventOrgan systemGroupAffectedAt riskEventsSource

Adverse event totals 0

The totals the trial posted for each group.

TotalGroupAffectedAt riskSource

Papers 0

The papers the trial lists on ClinicalTrials.gov.

PMIDListed asSource

Grants 0

The grants NIH RePORTER links to the trial, newest funded first: NIH's, and some of AHRQ's, CDC's, FDA's and VA's. Each shows its title, principal investigators, organization and funder in its newest year.

ProjectTitlePrincipal investigatorsOrganizationFunderFiscal yearsSource

Trial comparisons 0

Comparisons of the trial's two groups, calculated by ConductScience from the counts it posted.

ComparisonSource

Tests 0

The ConductCognition tests this trial's registered outcomes name, as ScienceGraph matched them in trial-tests-2026-11-12-0.2.1.

TestNamed asSource

Source 5

FieldValueSource
Releasetrials-2026-11-12-0.4.0ClinicalTrials.gov
Release manifest SHA-2560f4a8d8c48aee2a7573ae0fa94ecbeab70c1adbe449bbc95c424bc7d3e97b9d4ClinicalTrials.gov
Registry capture2026-11-12ClinicalTrials.gov
Results copy, AACT2026-03-23ClinicalTrials.gov
NIH clinical studies file2026-11-13ClinicalTrials.gov

The same record as JSON

Release trials-2026-11-12-0.4.0

ClinicalTrials.gov's posted results, through CTTI's AACT: ClinicalTrials.gov data via Aggregate Analysis of ClinicalTrials.gov (AACT), CTTI. CTTI makes its materials freely available and requests acknowledgement. https://aact.ctti-clinicaltrials.org/documentation/299 ClinicalTrials.gov's data carry an international copyright outside the United States: https://clinicaltrials.gov/about-site/terms-conditions.

ClinicalTrials.gov: none stated ClinicalTrials.gov's data carry an international copyright outside the United States: https://clinicaltrials.gov/about-site/terms-conditions.

NIH RePORTER's clinical studies and project files: Public domain (NIH RePORTER)