ConductScience.org, home

Library / Trials

Arduino-Based Real-Time Feedback for Manikin Endotracheal Intubation Training in Medical Students

NCT07927231, Not applicable, Completed, Tri-Service General Hospital (TSGH)

Trial 10

As registered on ClinicalTrials.gov, in the graph's capture of the registry.

FieldValueSource
TitleArduino-Based Real-Time Feedback for Manikin Endotracheal Intubation Training in Medical StudentsClinicalTrials.gov
NCT numberNCT07927231ClinicalTrials.gov
StatusCompletedClinicalTrials.gov
PhasesNot applicableClinicalTrials.gov
Enrollment80 participants, actualClinicalTrials.gov
Lead sponsorTri-Service General Hospital (TSGH)ClinicalTrials.gov
ConditionsEndotracheal Intubation, Medical Education, Simulation TrainingClinicalTrials.gov
InterventionsArduino-based real-time feedback laryngoscope, Structured airway-management courseClinicalTrials.gov
First posted2026-11-10ClinicalTrials.gov
Last updated2026-11-10ClinicalTrials.gov

Registered outcomes 6

Each outcome the trial registered, primary first, in ClinicalTrials.gov's words.

ListOutcomeTime frameDescriptionSource
PrimaryUpper-incisor pressure scoreBefore training (pretest) and immediately after training (posttest), within the same teaching session
Unitless score generated by the pressure-sensing laryngoscope during a manikin intubation attempt; higher scores indicate less loading of the upper incisors. The posttest score is compared between arms with adjustment for the pretest score.
ClinicalTrials.gov
SecondaryAutonomyBefore training (pretest) and immediately after training (posttest), within the same teaching sessionFour-item learner-reported scale with 5-point responses (1, strongly disagree, to 5, strongly agree); total score range 4-20, higher scores indicate greater perceived autonomy.ClinicalTrials.gov
SecondaryCompetenceBefore training (pretest) and immediately after training (posttest), within the same teaching sessionFour-item learner-reported scale with 5-point responses; total score range 4-20, higher scores indicate greater perceived competence.ClinicalTrials.gov
SecondaryIntubation self-efficacyBefore training (pretest) and immediately after training (posttest), within the same teaching sessionSeven-item learner-reported scale with 5-point responses; total score range 7-35, higher scores indicate greater intubation self-efficacy.ClinicalTrials.gov
SecondaryCourse satisfactionImmediately after trainingMean score of three postcourse items with 5-point responses; range 1-5, higher scores indicate greater satisfaction.ClinicalTrials.gov
SecondaryOperating-room intubation successDuring the clinical anesthesiology rotation following trainingProportion of successful endotracheal intubation attempts on patients in the operating room, with two to four scored attempts (success or failure) per student.ClinicalTrials.gov

Outcomes 0

Each outcome the trial posted results for, in ClinicalTrials.gov's words.

TypeOutcomeTime framePopulationUnitsMeasured asSource

Results by group 0

Each measurement the trial posted, group by group, in the words and numbers it posted.

OutcomeGroupCategoryValueSpreadUnitsSource

Participant flow 0

How many started, completed or left each group, period by period.

PeriodMilestoneGroupParticipantsUnits countedSource

Adverse events 0

Each adverse event the trial posted, group by group: the participants affected out of those at risk.

TypeEventOrgan systemGroupAffectedAt riskEventsSource

Adverse event totals 0

The totals the trial posted for each group.

TotalGroupAffectedAt riskSource

Papers 0

The papers the trial lists on ClinicalTrials.gov.

PMIDListed asSource

Grants 0

The grants NIH RePORTER links to the trial, newest funded first: NIH's, and some of AHRQ's, CDC's, FDA's and VA's. Each shows its title, principal investigators, organization and funder in its newest year.

ProjectTitlePrincipal investigatorsOrganizationFunderFiscal yearsSource

Trial comparisons 0

Comparisons of the trial's two groups, calculated by ConductScience from the counts it posted.

ComparisonSource

Tests 0

The ConductCognition tests this trial's registered outcomes name, as ScienceGraph matched them in trial-tests-2026-11-12-0.2.1.

TestNamed asSource

Source 5

FieldValueSource
Releasetrials-2026-11-12-0.4.0ClinicalTrials.gov
Release manifest SHA-2560f4a8d8c48aee2a7573ae0fa94ecbeab70c1adbe449bbc95c424bc7d3e97b9d4ClinicalTrials.gov
Registry capture2026-11-12ClinicalTrials.gov
Results copy, AACT2026-03-23ClinicalTrials.gov
NIH clinical studies file2026-11-13ClinicalTrials.gov

The same record as JSON

Release trials-2026-11-12-0.4.0

ClinicalTrials.gov's posted results, through CTTI's AACT: ClinicalTrials.gov data via Aggregate Analysis of ClinicalTrials.gov (AACT), CTTI. CTTI makes its materials freely available and requests acknowledgement. https://aact.ctti-clinicaltrials.org/documentation/299 ClinicalTrials.gov's data carry an international copyright outside the United States: https://clinicaltrials.gov/about-site/terms-conditions.

ClinicalTrials.gov: none stated ClinicalTrials.gov's data carry an international copyright outside the United States: https://clinicaltrials.gov/about-site/terms-conditions.

NIH RePORTER's clinical studies and project files: Public domain (NIH RePORTER)