ConductScience.org, home

Comparison · NCT02909907-deaths

Flexors Alone vs Flexors Plus Extensors: deaths from any cause

Calculated by ConductScience from the counts the trial posted to ClinicalTrials.gov.

2 sourcestrial-comparisons-2026-03-23-0.1.0

Download JSON
Cite this record

ConductScience Library. Flexors Alone vs Flexors Plus Extensors: deaths from any cause. Trial comparisons, record NCT02909907-deaths. Release trial-comparisons-2026-03-23-0.1.0, 23 Mar 2026. https://conductscience.org/library/comparisons/NCT02909907-deaths

On this page

Measures6

Calculated by ConductScience from the counts the trial posted to ClinicalTrials.gov.

MeasureValue95% interval, lower95% interval, upperMethodNote
Risk in group 1000.278wilson
Risk in group 2000.299wilson
Risk difference, group 1 minus group 20-0.2990.278newcombe hybrid score
Risk ratio, group 1 over group 2loga group has no participants with the outcome
Odds ratio, group 1 over group 2loga cell of the two-by-two table is zero
Number needed to harmfrom the risk difference intervalthe two groups' risks are equal

Groups2

Neither group, or both, names a comparator, so the groups keep ClinicalTrials.gov's order.

GroupTitleDescriptionWith the outcomeAnalysedClinicalTrials.gov code
Group 1Flexors Alone75 units of abobotulinumtoxinA in FCR and FCU and 25 units in ECR and ECU~Botulinum toxin: Botulinum injections into dominant upper extremity using protocol outlined above.010EG000
Group 2Flexors Plus Extensors
150 units of abobotulinumtoxinA in flexor compartment of dominant arm (75 units in flexor carpi radialis \[FCR\] and 75 units in flexor carpi ulnaris \[FCU\]) along with placebo in extensor carpi radialis (ECR) and extensor carpi ulnaris (ECU)~Botulinum toxin: Botulinum injections into dominant upper extremity using protocol outlined above.~Placebo: Placebo injections in extensor carpi radialis (ECR) and extensor carpi ulnaris (ECU) per protocol outlined above
09EG001

Harm

What it counts
Total, all-cause mortality
Time frame
12 weeks

Source ClinicalTrials.gov

Trial

Title
Comparison of Botulinum Toxin Injections in Forearm FLexor Plus EXtensor Muscles vs. Flexor Muscles Alone for Treatment of Essential Hand Tremor(FLEX-D ET)
NCT number
NCT02909907
Phases
NA
Conditions
Essential Tremor
Interventions
Botulinum toxin, Placebo
Lead sponsor
The Cleveland Clinic
Results first posted
2019-04-23

Source ClinicalTrials.gov

Source

Release
trial-comparisons-2026-03-23-0.1.0
Release manifest SHA-256
f66225897fbf258b57ea10bdacfd0347d3cdfda93f7f5685234b7e06ea36fa57
AACT copy
2026-03-23
Tables read
outcome_counts.parquet, outcome_measurements.parquet, outcomes.parquet, reported_event_totals.parquet, reported_events.parquet, result_groups.parquet, studies.parquet, ctgov_trial.parquet

Source ClinicalTrials.gov

Sources 2

  • ClinicalTrials.gov's posted results, through CTTI's AACTFreely available. Acknowledgement requested
  • ClinicalTrials.govNo license stated
Each source's terms
  • ClinicalTrials.gov's posted results, through CTTI's AACTClinicalTrials.gov data via Aggregate Analysis of ClinicalTrials.gov (AACT), CTTI. CTTI makes its materials freely available and requests acknowledgement. https://aact.ctti-clinicaltrials.org/documentation/299
  • ClinicalTrials.govnone stated

ClinicalTrials.gov's data carry an international copyright outside the United States: https://clinicaltrials.gov/about-site/terms-conditions. The measures are ConductScience's calculation from them.

For software

Read this comparison from software.

The record is JSON. No key.