ConductScience.org, home

Paper20176359

Effects of idealized joint geometry on finite element predictions of cartilage contact stresses in the hip.

Anderson AE and 3 others. J Biomech, 2010. Cited by 129 papers, by iCite.

Cite this record

ConductScience Library. Effects of idealized joint geometry on finite element predictions of cartilage contact stresses in the hip. Papers, record 20176359. Release papers-2026-11-12-0.1.0, 12 Nov 2026. https://conductscience.org/library/papers/20176359

Sign in to download
Sources
11 sources
Release
papers-2026-11-12-0.1.0

Paper

PubMed's record of the paper, with iCite's citation figures. No abstract is shown.

Title
Effects of idealized joint geometry on finite element predictions of cartilage contact stresses in the hip.
PubMed
Journal
J Biomech
PubMed
Year
2010
PubMed
Publication types
Journal Article, Research Support, N.I.H., Extramural
PubMed
Citations, by iCite
129
iCite
Relative citation ratio, by iCite
6.78
iCite
Revised in PubMed
2025-05-29
PubMed

Authors4

The authors in the order PubMed's record lists them, with the ORCID iDs it states.

OrderAuthorForenameKindORCID iD
1Anderson AEAndrew E
2Ellis BJBenjamin J
3Maas SASteve A
4Weiss JAJeffrey A

Source PubMed

Sign in to download

Topics10

NLM's MeSH indexing of the paper, its major topics first.

MeSH termMajor
CartilageMajor topic
Hip JointMajor topic
Models, BiologicalMajor topic
Stress, PhysiologicalMajor topic
WalkingMajor topic
Animals
Finite Element Analysis
Humans
Range of Motion, Articular
Weight-Bearing

Source PubMed

Sign in to download

Grants2

Each grant PubMed's record writes, matched to the NIH project NIH's grant and paper links name for this paper, and each of those links the record does not write.

Grant, as the record writes itAgencyCountryNIH projectStated bySource
R01 AR053344NIAMS NIH HHSUnited StatesR01AR053344PubMed and NIHNIH RePORTER
R01 GM083925NIGMS NIH HHSUnited StatesR01GM083925PubMed and NIHNIH RePORTER

Sign in to download

References39

The papers the reference list in PubMed's record names, those in our copy of PubMed, in the list's order.

OrderPMIDTitleJournalYearIn PapersSource
112454409Investigation of mechanical behavior of articular cartilage by fibril reinforced poroelastic models.Biorheology2003https://conductscience.org/library/papers/12454409PubMed
28739371Stress distribution on the hip joint articular surface during gait.Pflugers Arch1996https://conductscience.org/library/papers/8739371PubMed
33611154Contact pressures in the human hip joint.J Bone Joint Surg Br1987https://conductscience.org/library/papers/3611154PubMed
412446159A finite element model of the shoulder: application to the comparison of normal and osteoarthritic joints.Clin Biomech (Bristol)2002https://conductscience.org/library/papers/12446159PubMed
510343537Thickness of human articular cartilage in joints of the lower limb.Ann Rheum Dis1999https://conductscience.org/library/papers/10343537PubMed
69302622The hip joint as a conchoid shape.J Biomech1997https://conductscience.org/library/papers/9302622PubMed
78189704Cartilage stresses in the human hip joint.J Biomech Eng1994https://conductscience.org/library/papers/8189704PubMed
814697684Mechanical response of bovine articular cartilage under dynamic unconfined compression loading at physiological stress levels.Osteoarthritis Cartilage2004https://conductscience.org/library/papers/14697684PubMed
918096534Cartilage thickness: factors influencing multidetector CT measurements in a phantom study.Radiology2008https://conductscience.org/library/papers/18096534PubMed
1011410170Hip contact forces and gait patterns from routine activities.J Biomech2001https://conductscience.org/library/papers/11410170PubMed
1117035063Finite element modelling of the pelvis: inclusion of muscular and ligamentous boundary conditions.Med Eng Phys2007https://conductscience.org/library/papers/17035063PubMed
1217271300Hip joint center location by fitting conchoid shape to the acetabular rim region of MR images.Conf Proc IEEE Eng Med Biol Soc2004https://conductscience.org/library/papers/17271300PubMed
1315519348The effect of muscle loading on the simulation of bone remodelling in the proximal femur.J Biomech2005https://conductscience.org/library/papers/15519348PubMed
1417536908Equivalence between short-time biphasic and incompressible elastic material responses.J Biomech Eng2007https://conductscience.org/library/papers/17536908PubMed
1516120442Three-dimensional dynamic hip contact area and pressure distribution during activities of daily living.J Biomech2006https://conductscience.org/library/papers/16120442PubMed
1611410173Normal hip joint contact pressure distribution in single-leg standing--effect of gender and anatomic parameters.J Biomech2001https://conductscience.org/library/papers/11410173PubMed
1715577484Debridement of the adult hip for femoroacetabular impingement: indications and preliminary clinical results.Clin Orthop Relat Res2004https://conductscience.org/library/papers/15577484PubMed
1812547354An in vitro investigation of the acetabular labral seal in hip joint mechanics.J Biomech2003https://conductscience.org/library/papers/12547354PubMed
1910204935Retroversion of the acetabulum. A cause of hip pain.J Bone Joint Surg Br1999https://conductscience.org/library/papers/10204935PubMed
2012186728Computer determination of contact stress distribution and size of weight bearing area in the human hip joint.Comput Methods Biomech Biomed Engin2002https://conductscience.org/library/papers/12186728PubMed

See all 39 referencesSign in to download

Cited by62

The papers in our copy of PubMed whose reference list names this one, newest first. iCite, which reads more sources, counts 129 citations.

PMIDTitleJournalYearIn PapersSource
42470192High-Fidelity Measurement-Based Detection Values and Roles of Three-Dimensional Joint Space Width in Evaluation of Knee Osteoarthritis.Orthop Surg2026https://conductscience.org/library/papers/42470192PubMed
42180020Radiographic measures of hip dysplasia correlate only moderately with computationally derived contact mechanics.J Hip Preserv Surg2026https://conductscience.org/library/papers/42180020PubMed
42054848Effects of bone deformation on patient-specific finite element predictions of hip chondrolabral mechanics.J Mech Behav Biomed Mater2026https://conductscience.org/library/papers/42054848PubMed
41581420Standing anterior pelvic tilt is correlated with the proximal femur shape of individuals with cam morphology.Clin Biomech (Bristol)2026https://conductscience.org/library/papers/41581420PubMed
41344985In silico analysis of fixation device strain patterns in the postoperative proximal femur: Effects of bone quality during gait.Clin Biomech (Bristol)2025https://conductscience.org/library/papers/41344985PubMed
40893343Multivariate Quantitative Outcomes of Periacetabular Osteotomy Using Discrete Element Analysis.Adv Orthop2025https://conductscience.org/library/papers/40893343PubMed
40849362Accuracy and Reliability of Synthetic Computed Tomography for Model-Based Tracking of Biplane Videoradiography Data.Ann Biomed Eng2025https://conductscience.org/library/papers/40849362PubMed
40705768Biomechanical analysis of hip, knee, and ankle joint contact forces during squats in elite powerlifters.PLoS One2025https://conductscience.org/library/papers/40705768PubMed
39846047Understanding Hip Contact Stress Based on Types of Physical Activity: A Systematic Review.Health Sci Rep2025https://conductscience.org/library/papers/39846047PubMed
39030968Persistently elevated joint contact stress after periacetabular osteotomy is associated with joint failure at minimum 10-year follow-up.J Orthop Res2024https://conductscience.org/library/papers/39030968PubMed
38680676Investigation of contact behavior on a model of the dual-mobility artificial hip joint for Asians in different inner liner thicknesses.World J Orthop2024https://conductscience.org/library/papers/38680676PubMed
38003908Finite Element Analysis of Normal and Dysplastic Hip Joints in Children.J Pers Med2023https://conductscience.org/library/papers/38003908PubMed
37370667An Integrated Method of Biomechanics Modeling for Pelvic Bone and Surrounding Soft Tissues.Bioengineering (Basel)2023https://conductscience.org/library/papers/37370667PubMed
37357248A Correspondence-Based Network Approach for Groupwise Analysis of Patient-Specific Spatiotemporal Data.Ann Biomed Eng2023https://conductscience.org/library/papers/37357248PubMed
35864367A Musculoskeletal Model for Estimating Hip Contact Pressure During Walking.Ann Biomed Eng2022https://conductscience.org/library/papers/35864367PubMed
35810204Cartilage thickness and bone shape variations as a function of sex, height, body mass, and age in young adult knees.Sci Rep2022https://conductscience.org/library/papers/35810204PubMed
35764011Effect of modeling femoral version and head-neck offset correction on computed contact mechanics in dysplastic hips treated with periacetabular osteotomy.J Biomech2022https://conductscience.org/library/papers/35764011PubMed
35568957Changes in hip joint contact stress during a gait cycle based on the individualized modeling method of "gait-musculoskeletal system-finite element".J Orthop Surg Res2022https://conductscience.org/library/papers/35568957PubMed
35299631Role of the Anterior Center-Edge Angle on Acetabular Stress Distribution in Borderline Development Dysplastic of Hip Determined by Finite Element Analysis.Front Bioeng Biotechnol2022https://conductscience.org/library/papers/35299631PubMed
34041519A Method to Compare Heterogeneous Types of Bone and Cartilage Meshes.J Biomech Eng2021https://conductscience.org/library/papers/34041519PubMed

See all 62 cited bySign in to download

Data dates

The date of each source this release read.

PubMed
2026-11-06
PubMed
iCite
2026-11-05
iCite
PMC's ID file
2026-11-05
PMC's ID file
NIH RePORTER's grant and paper links
2026-11-01
NIH RePORTER's grant and paper links
Trials
2026-11-12
Gene search
2026-11-11
Pipelines
2026-09-18

None in this release

  • Trials
  • Comments and corrections
  • Genes
  • Drugs
  • Data

Sources 11

  • ChEMBL, through Open TargetsCC BY-SA 3.0
  • ClinicalTrials.govNo license stated
  • HGNCCC0
  • iCiteCC BY 4.0
  • NCBI GenePublic domain (US government)
  • NIH RePORTER's grant and paper linksPublic domain
  • Open TargetsCC0 1.0
  • PMC's ID filePublic domain (US government)
  • PubMedNLM's terms
  • PubTator 3Public domain
  • UniProtCC BY 4.0
Each source's terms
  • ChEMBL, through Open TargetsCC BY-SA 3.0, for the parts from ChEMBL. Read on 8 Nov 2026 at https://platform-docs.opentargets.org/licence
  • ClinicalTrials.govnone stated
  • HGNCCC0: https://www.genenames.org/about/license/
  • iCiteCC BY 4.0
  • NCBI GeneNone named for the file. NCBI says information created by or for the US government on its site is in the public domain, and asks that NLM be acknowledged: https://www.ncbi.nlm.nih.gov/home/about/policies/
  • NIH RePORTER's grant and paper linksPublic domain (NIH RePORTER)
  • Open TargetsCC0 1.0. Open Targets asks that users cite its latest paper: Buniello et al. 2025, Open Targets Platform: facilitating therapeutic hypotheses building in drug discovery, Nucleic Acids Research 53(D1):D1467, PMID 39657122. Read on 8 Nov 2026 at https://platform-docs.opentargets.org/licence
  • PMC's ID fileNone named for the file. NCBI says information created by or for the US government on its site is in the public domain, and asks that NLM be acknowledged: https://www.ncbi.nlm.nih.gov/home/about/policies/
  • PubMedNLM's terms
  • PubTator 3Public domain
  • UniProtCC BY 4.0. UniProt's licence file: "All databases and documents in the UniProt FTP directory may be copied and redistributed freely, without advance permission, provided that this copyright statement is reproduced with each copy." UniProt asks that users cite its latest paper: The UniProt Consortium, UniProt: the Universal Protein Knowledgebase in 2025, Nucleic Acids Research 53:D609-D617, https://doi.org/10.1093/nar/gkae1010. Read on 9 Nov 2026 at https://www.uniprot.org/help/license

ClinicalTrials.gov's data carry an international copyright outside the United States: https://clinicaltrials.gov/about-site/terms-conditions.

For software

Read this paper from software.

The record and each of its lists are JSON, twenty rows a page. No key needed for records and first pages, up to 100 calls a day. With a free key, your account gets 2,000 a day and every page.

GET https://conductscience.org/api/papers/v1/20176359

GET https://conductscience.org/api/papers/v1/20176359/references?page=2