ConductScience.org, home

Paper20729451

Abdominal CT: comparison of low-dose CT with adaptive statistical iterative reconstruction and routine-dose CT with filtered back projection in 53 patients.

Sagara Y and 5 others. AJR Am J Roentgenol, 2010. Cited by 317 papers, by iCite.

Cite this record

ConductScience Library. Abdominal CT: comparison of low-dose CT with adaptive statistical iterative reconstruction and routine-dose CT with filtered back projection in 53 patients. Papers, record 20729451. Release papers-2026-11-12-0.1.0, 12 Nov 2026. https://conductscience.org/library/papers/20729451

Sign in to download
Sources
11 sources
Release
papers-2026-11-12-0.1.0

Paper

PubMed's record of the paper, with iCite's citation figures. No abstract is shown.

Title
Abdominal CT: comparison of low-dose CT with adaptive statistical iterative reconstruction and routine-dose CT with filtered back projection in 53 patients.
PubMed
Journal
AJR Am J Roentgenol
PubMed
Year
2010
PubMed
Publication types
Comparative Study, Journal Article
PubMed
Citations, by iCite
317
iCite
Relative citation ratio, by iCite
12.9
iCite
Revised in PubMed
2022-04-09
PubMed

Authors6

The authors in the order PubMed's record lists them, with the ORCID iDs it states.

OrderAuthorForenameKindORCID iD
1Sagara YYoshiko
2Hara AKAmy K
3Pavlicek WWilliam
4Silva ACAlvin C
5Paden RGRobert G
6Wu QQing

Source PubMed

Sign in to download

Topics16

NLM's MeSH indexing of the paper, its major topics first.

MeSH termMajor
Radiographic Image EnhancementMajor topic
Radiographic Image Interpretation, Computer-AssistedMajor topic
Radiography, AbdominalMajor topic
Tomography, X-Ray ComputedMajor topic
Adult
Aged
Aged, 80 and over
Artifacts
Contrast Media
Female
Humans
Male
Middle Aged
Models, Statistical
Radiation Dosage
Retrospective Studies

Source PubMed

Sign in to download

Cited by140

The papers in our copy of PubMed whose reference list names this one, newest first. iCite, which reads more sources, counts 317 citations.

PMIDTitleJournalYearIn PapersSource
42739292Feasibility of AI-Denoised Ultra-Low-Dose CT for Detection of Acute Pelvic and Hip Fractures: A Pilot Multi-Reader Study.Diagnostics (Basel)2026https://conductscience.org/library/papers/42739292PubMed
42676850Application of Deep Learning Algorithm-Based Image Reconstruction in Improving Abdominal CT Image Quality in Adrenal and Renal Lesions Detection.Radiol Res Pract2026https://conductscience.org/library/papers/42676850PubMed
42095993Reconstruction algorithms and arm positioning effects on abdominal CT image quality and radiation dose: a phantom study.Eur Radiol Exp2026https://conductscience.org/library/papers/42095993PubMed
41464236
Balloon-Occluded Hepatic Radioembolization with Yttrium-90 (b-TARE) in Selected Patients with Unresectable Heterogeneous Hepatocellular Carcinoma (HCC): A Safe and Effective Approach to Improve the Dose Rate.
Diagnostics (Basel)2025https://conductscience.org/library/papers/41464236PubMed
41049920Abdominal Wall in Cross-Sectional Imaging as an Essential Knowledge for Radiologists: A Pictorial Review.Cureus2025https://conductscience.org/library/papers/41049920PubMed
40863875Imaging on the Edge: Mapping Object Corners and Edges with Stereo X-Ray Tomography.Tomography2025https://conductscience.org/library/papers/40863875PubMed
40670595Image quality and radiation dose of reduced-dose abdominopelvic computed tomography (CT) with silver filter and deep learning reconstruction.Sci Rep2025https://conductscience.org/library/papers/40670595PubMed
39330757Skeletal Muscle Segmentation at the Level of the Third Lumbar Vertebra (L3) in Low-Dose Computed Tomography: A Lightweight Algorithm.Tomography2024https://conductscience.org/library/papers/39330757PubMed
38393291Feasibility of Low-Dose and Low-Contrast Media Volume Approach in Computed Tomography Cardiovascular Imaging Reconstructed with Model-Based Algorithm.Tomography2024https://conductscience.org/library/papers/38393291PubMed
38148622A comparative study of low voltage, low contrast cerebral computed tomography angiography with iterative reconstruction and conventional cerebral computed tomography angiography.Neuroradiol J2024https://conductscience.org/library/papers/38148622PubMed
37627855Design and Validation of a Deep Learning Model for Renal Stone Detection and Segmentation on Kidney-Ureter-Bladder Images.Bioengineering (Basel)2023https://conductscience.org/library/papers/37627855PubMed
36926443Quality Assessment of Computed Tomography Images using a Channelized Hoteling Observer: Optimization of Protocols in Clinical Practice.Adv Biomed Res2023https://conductscience.org/library/papers/36926443PubMed
36915333The value of using a deep learning image reconstruction algorithm of thinner slice thickness to balance the image noise and spatial resolution in low-dose abdominal CT.Quant Imaging Med Surg2023https://conductscience.org/library/papers/36915333PubMed
36551017Deep Learning Model for Computer-Aided Diagnosis of Urolithiasis Detection from Kidney-Ureter-Bladder Images.Bioengineering (Basel)2022https://conductscience.org/library/papers/36551017PubMed
36174098Development of deep learning-assisted overscan decision algorithm in low-dose chest CT: Application to lung cancer screening in Korean National CT accreditation program.PLoS One2022https://conductscience.org/library/papers/36174098PubMed
35658908Assessment of low-dose paranasal sinus CT imaging using a new deep learning image reconstruction technique in children compared to adaptive statistical iterative reconstruction V (ASiR-V).BMC Med Imaging2022https://conductscience.org/library/papers/35658908PubMed
35289146Image Quality and Lesion Detectability of Lower-Dose Abdominopelvic CT Obtained Using Deep Learning Image Reconstruction.Korean J Radiol2022https://conductscience.org/library/papers/35289146PubMed
35286578Unenhanced abdominal low-dose CT reconstructed with deep learning-based image reconstruction: image quality and anatomical structure depiction.Jpn J Radiol2022https://conductscience.org/library/papers/35286578PubMed
35140296Image quality and diagnostic accuracy of reduced-dose computed tomography enterography with model-based iterative reconstruction in pediatric Crohn's disease patients.Sci Rep2022https://conductscience.org/library/papers/35140296PubMed
35095544Simulated Annealing-Based Image Reconstruction for Patients With COVID-19 as a Model for Ultralow-Dose Computed Tomography.Front Physiol2021https://conductscience.org/library/papers/35095544PubMed

See all 140 cited bySign in to download

Data dates

The date of each source this release read.

PubMed
2026-11-06
PubMed
iCite
2026-11-05
iCite
PMC's ID file
2026-11-05
PMC's ID file
NIH RePORTER's grant and paper links
2026-11-01
NIH RePORTER's grant and paper links
Trials
2026-11-12
Gene search
2026-11-11
Pipelines
2026-09-18

None in this release

  • Grants
  • Trials
  • Comments and corrections
  • References
  • Genes
  • Drugs
  • Data

Sources 11

  • ChEMBL, through Open TargetsCC BY-SA 3.0
  • ClinicalTrials.govNo license stated
  • HGNCCC0
  • iCiteCC BY 4.0
  • NCBI GenePublic domain (US government)
  • NIH RePORTER's grant and paper linksPublic domain
  • Open TargetsCC0 1.0
  • PMC's ID filePublic domain (US government)
  • PubMedNLM's terms
  • PubTator 3Public domain
  • UniProtCC BY 4.0
Each source's terms
  • ChEMBL, through Open TargetsCC BY-SA 3.0, for the parts from ChEMBL. Read on 8 Nov 2026 at https://platform-docs.opentargets.org/licence
  • ClinicalTrials.govnone stated
  • HGNCCC0: https://www.genenames.org/about/license/
  • iCiteCC BY 4.0
  • NCBI GeneNone named for the file. NCBI says information created by or for the US government on its site is in the public domain, and asks that NLM be acknowledged: https://www.ncbi.nlm.nih.gov/home/about/policies/
  • NIH RePORTER's grant and paper linksPublic domain (NIH RePORTER)
  • Open TargetsCC0 1.0. Open Targets asks that users cite its latest paper: Buniello et al. 2025, Open Targets Platform: facilitating therapeutic hypotheses building in drug discovery, Nucleic Acids Research 53(D1):D1467, PMID 39657122. Read on 8 Nov 2026 at https://platform-docs.opentargets.org/licence
  • PMC's ID fileNone named for the file. NCBI says information created by or for the US government on its site is in the public domain, and asks that NLM be acknowledged: https://www.ncbi.nlm.nih.gov/home/about/policies/
  • PubMedNLM's terms
  • PubTator 3Public domain
  • UniProtCC BY 4.0. UniProt's licence file: "All databases and documents in the UniProt FTP directory may be copied and redistributed freely, without advance permission, provided that this copyright statement is reproduced with each copy." UniProt asks that users cite its latest paper: The UniProt Consortium, UniProt: the Universal Protein Knowledgebase in 2025, Nucleic Acids Research 53:D609-D617, https://doi.org/10.1093/nar/gkae1010. Read on 9 Nov 2026 at https://www.uniprot.org/help/license

ClinicalTrials.gov's data carry an international copyright outside the United States: https://clinicaltrials.gov/about-site/terms-conditions.

For software

Read this paper from software.

The record and each of its lists are JSON, twenty rows a page. No key needed for records and first pages, up to 100 calls a day. With a free key, your account gets 2,000 a day and every page.

GET https://conductscience.org/api/papers/v1/20729451

GET https://conductscience.org/api/papers/v1/20729451/cited_by?page=2