Paper21656331
High-resolution spiral CT of the breast at very low dose: concept and feasibility considerations.
Kalender WA and 5 others. Eur Radiol, 2012. Cited by 91 papers, by iCite.
Cite this record
ConductScience Library. High-resolution spiral CT of the breast at very low dose: concept and feasibility considerations. Papers, record 21656331. Release papers-2026-11-12-0.1.0, 12 Nov 2026. https://conductscience.org/library/papers/21656331
- Sources
- 11 sources
- Release
- papers-2026-11-12-0.1.0
Paper
PubMed's record of the paper, with iCite's citation figures. No abstract is shown.
- Title
- High-resolution spiral CT of the breast at very low dose: concept and feasibility considerations.
- PubMed
Topics11
NLM's MeSH indexing of the paper, its major topics first.
| MeSH term | Major |
|---|---|
| Breast | Major topic |
| Breast Diseases | Major topic |
| Calcinosis | Major topic |
| Mammography | Major topic |
| Tomography, Spiral Computed | Major topic |
| Computer Simulation | |
| Feasibility Studies | |
| Female | |
| Humans | |
| Phantoms, Imaging | |
| Radiation Dosage |
Source PubMed
References23
The papers the reference list in PubMed's record names, those in our copy of PubMed, in the list's order.
| Order | PMID | Title | Journal | Year | In Papers | Source |
|---|---|---|---|---|---|---|
| 1 | 11474928 | Ordered subset reconstruction for x-ray CT. | Phys Med Biol | 2001 | https://conductscience.org/library/papers/11474928 | PubMed |
| 2 | 19561253 | Effects of adaptive section collimation on patient radiation dose in multisection spiral CT. | Radiology | 2009 | https://conductscience.org/library/papers/19561253 | PubMed |
| 3 | 15451209 | What should the burden of proof be for acceptance of a new breast-cancer screening technique? | Lancet | 2004 | https://conductscience.org/library/papers/15451209 | PubMed |
| 4 | 20033175 | Digital breast tomosynthesis versus digital mammography: a clinical performance study. | Eur Radiol | 2010 | https://conductscience.org/library/papers/20033175 | PubMed |
| 5 | 20720067 | Contrast-enhanced dedicated breast CT: initial clinical experience. | Radiology | 2010 | https://conductscience.org/library/papers/20720067 | PubMed |
| 6 | 15000608 | A comprehensive analysis of DgN(CT) coefficients for pendant-geometry cone-beam breast computed tomography. | Med Phys | 2004 | https://conductscience.org/library/papers/15000608 | PubMed |
| 7 | 18195383 | Dedicated breast CT: initial clinical experience. | Radiology | 2008 | https://conductscience.org/library/papers/18195383 | PubMed |
| 8 | 12355001 | Comparison of the performance of screening mammography, physical examination, and breast US and evaluation of factors that influence them: an analysis of 27,825 patient evaluations. | Radiology | 2002 | https://conductscience.org/library/papers/12355001 | PubMed |
| 9 | 21361181 | Spectral optimization for dedicated breast CT. | Med Phys | 2011 | https://conductscience.org/library/papers/21361181 | PubMed |
| 10 | 16293877 | Mammography, breast ultrasound, and magnetic resonance imaging for surveillance of women at high familial risk for breast cancer. | J Clin Oncol | 2005 | https://conductscience.org/library/papers/16293877 | PubMed |
| 11 | 15280183 | An overview of the status of imaging screening technology for breast cancer. | Ann Oncol | 2004 | https://conductscience.org/library/papers/15280183 | PubMed |
| 12 | 16775176 | Breast density and parenchymal patterns as markers of breast cancer risk: a meta-analysis. | Cancer Epidemiol Biomarkers Prev | 2006 | https://conductscience.org/library/papers/16775176 | PubMed |
| 13 | 11719660 | Dedicated breast CT: radiation dose and image quality evaluation. | Radiology | 2001 | https://conductscience.org/library/papers/11719660 | PubMed |
| 14 | 21081671 | Risk of radiation-induced breast cancer from mammographic screening. | Radiology | 2011 | https://conductscience.org/library/papers/21081671 | PubMed |
| 15 | 12558355 | Individual and combined effects of age, breast density, and hormone replacement therapy use on the accuracy of screening mammography. | Ann Intern Med | 2003 | https://conductscience.org/library/papers/12558355 | PubMed |
| 16 | 20093597 | Comparison of acquisition parameters and breast dose in digital mammography and screen-film mammography in the American College of Radiology Imaging Network digital mammographic imaging screening trial. | AJR Am J Roentgenol | 2010 | https://conductscience.org/library/papers/20093597 | PubMed |
| 17 | 20651210 | Cone-beam CT for breast imaging: Radiation dose, breast coverage, and image quality. | AJR Am J Roentgenol | 2010 | https://conductscience.org/library/papers/20651210 | PubMed |
| 18 | 20879571 | Dosimetric characterization of a dedicated breast computed tomography clinical prototype. | Med Phys | 2010 | https://conductscience.org/library/papers/20879571 | PubMed |
| 19 | 19657655 | Breast tomosynthesis in clinical practice: initial results. | Eur Radiol | 2010 | https://conductscience.org/library/papers/19657655 | PubMed |
| 20 | 19620460 | Digital breast tomosynthesis: observer performance study. | AJR Am J Roentgenol | 2009 | https://conductscience.org/library/papers/19620460 | PubMed |
Cited by44
The papers in our copy of PubMed whose reference list names this one, newest first. iCite, which reads more sources, counts 91 citations.
| PMID | Title | Journal | Year | In Papers | Source |
|---|---|---|---|---|---|
| 42597632 | Radiation dose comparison of photon-counting breast CT and mammography: A phantom study. | Eur J Radiol Open | 2026 | https://conductscience.org/library/papers/42597632 | PubMed |
| 39661124 | [Parametric imaging in breast diagnostics : Computed tomography]. | Radiologie (Heidelb) | 2025 | https://conductscience.org/library/papers/39661124 | PubMed |
| 37987346 | Dedicated Cone-Beam Breast CT: Reproducibility of Volumetric Glandular Fraction with Advanced Image Reconstruction Methods. | Tomography | 2023 | https://conductscience.org/library/papers/37987346 | PubMed |
| 37646463 | Pre-whitened matched filter and convolutional neural network based model observer performance for mass lesion detection in non-contrast breast CT. | Med Phys | 2023 | https://conductscience.org/library/papers/37646463 | PubMed |
| 34342694 | Dedicated breast CT: state of the art-Part I. Historical evolution and technical aspects. | Eur Radiol | 2022 | https://conductscience.org/library/papers/34342694 | PubMed |
| 34065039 | Detection of Microcalcifications in Spiral Breast Computed Tomography with Photon-Counting Detector Is Feasible: A Specimen Study. | Diagnostics (Basel) | 2021 | https://conductscience.org/library/papers/34065039 | PubMed |
| 32855995 | Segmentation of breast masses on dedicated breast computed tomography and three-dimensional breast ultrasound images. | J Med Imaging (Bellingham) | 2014 | https://conductscience.org/library/papers/32855995 | PubMed |
| 32791669 | Diagnostic value of a spiral breast computed tomography system equipped with photon counting detector technology in patients with implants: An observational study of our initial experiences. | Medicine (Baltimore) | 2020 | https://conductscience.org/library/papers/32791669 | PubMed |
| 32341937 | Dose and spatial resolution analysis of grating-based phase-contrast mammography using an inverse Compton x-ray source. | J Med Imaging (Bellingham) | 2020 | https://conductscience.org/library/papers/32341937 | PubMed |
| 32333575 | Dedicated cone-beam breast CT using laterally-shifted detector geometry: Quantitative analysis of feasibility for clinical translation. | J Xray Sci Technol | 2020 | https://conductscience.org/library/papers/32333575 | PubMed |
| 32233091 | Effects of kV, filtration, dose, and object size on soft tissue and iodine contrast in dedicated breast CT. | Med Phys | 2020 | https://conductscience.org/library/papers/32233091 | PubMed |
| 31780707 | Image quality comparison between a phase-contrast synchrotron radiation breast CT and a clinical breast CT: a phantom based study. | Sci Rep | 2019 | https://conductscience.org/library/papers/31780707 | PubMed |
| 31511550 | Optimization of the energy for Breast monochromatic absorption X-ray Computed Tomography. | Sci Rep | 2019 | https://conductscience.org/library/papers/31511550 | PubMed |
| 31102462 | Shading artifact correction in breast CT using an interleaved deep learning segmentation and maximum-likelihood polynomial fitting approach. | Med Phys | 2019 | https://conductscience.org/library/papers/31102462 | PubMed |
| 30525064 | Monochromatic breast computed tomography with synchrotron radiation: phase-contrast and phase-retrieved image comparison and full-volume reconstruction. | J Med Imaging (Bellingham) | 2019 | https://conductscience.org/library/papers/30525064 | PubMed |
| 29657646 | Iterative Reconstruction as a Method for Optimisation of Computed Tomography Procedures. | Pol J Radiol | 2017 | https://conductscience.org/library/papers/29657646 | PubMed |
| 29204328 | The Role of Affordable, Point-of-Care Technologies for Cancer Care in Low- and Middle-Income Countries: A Review and Commentary. | IEEE J Transl Eng Health Med | 2017 | https://conductscience.org/library/papers/29204328 | PubMed |
| 28924570 | Implementation and CT sampling characterization of a third-generation SPECT-CT system for dedicated breast imaging. | J Med Imaging (Bellingham) | 2017 | https://conductscience.org/library/papers/28924570 | PubMed |
| 28398906 | Evaluation of the BreastSimulator software platform for breast tomography. | Phys Med Biol | 2017 | https://conductscience.org/library/papers/28398906 | PubMed |
| 28170300 | Effect of Radiation Dose Reduction and Reconstruction Algorithm on Image Noise, Contrast, Resolution, and Detectability of Subtle Hypoattenuating Liver Lesions at Multidetector CT: Filtered Back Projection versus a Commercial Model-based Iterative Reconstruction Algorithm. | Radiology | 2017 | https://conductscience.org/library/papers/28170300 | PubMed |
Data dates
The date of each source this release read.
- Trials
- 2026-11-12
- Gene search
- 2026-11-11
- Pipelines
- 2026-09-18
None in this release
- Grants
- Trials
- Comments and corrections
- Genes
- Drugs
- Data
Sources 11
- ChEMBL, through Open TargetsCC BY-SA 3.0
- ClinicalTrials.govNo license stated
- HGNCCC0
- iCiteCC BY 4.0
- NCBI GenePublic domain (US government)
- NIH RePORTER's grant and paper linksPublic domain
- Open TargetsCC0 1.0
- PMC's ID filePublic domain (US government)
- PubMedNLM's terms
- PubTator 3Public domain
- UniProtCC BY 4.0
Each source's terms
- ChEMBL, through Open TargetsCC BY-SA 3.0, for the parts from ChEMBL. Read on 8 Nov 2026 at https://platform-docs.opentargets.org/licence
- ClinicalTrials.govnone stated
- HGNCCC0: https://www.genenames.org/about/license/
- iCiteCC BY 4.0
- NCBI GeneNone named for the file. NCBI says information created by or for the US government on its site is in the public domain, and asks that NLM be acknowledged: https://www.ncbi.nlm.nih.gov/home/about/policies/
- NIH RePORTER's grant and paper linksPublic domain (NIH RePORTER)
- Open TargetsCC0 1.0. Open Targets asks that users cite its latest paper: Buniello et al. 2025, Open Targets Platform: facilitating therapeutic hypotheses building in drug discovery, Nucleic Acids Research 53(D1):D1467, PMID 39657122. Read on 8 Nov 2026 at https://platform-docs.opentargets.org/licence
- PMC's ID fileNone named for the file. NCBI says information created by or for the US government on its site is in the public domain, and asks that NLM be acknowledged: https://www.ncbi.nlm.nih.gov/home/about/policies/
- PubMedNLM's terms
- PubTator 3Public domain
- UniProtCC BY 4.0. UniProt's licence file: "All databases and documents in the UniProt FTP directory may be copied and redistributed freely, without advance permission, provided that this copyright statement is reproduced with each copy." UniProt asks that users cite its latest paper: The UniProt Consortium, UniProt: the Universal Protein Knowledgebase in 2025, Nucleic Acids Research 53:D609-D617, https://doi.org/10.1093/nar/gkae1010. Read on 9 Nov 2026 at https://www.uniprot.org/help/license
ClinicalTrials.gov's data carry an international copyright outside the United States: https://clinicaltrials.gov/about-site/terms-conditions.
For software
Read this paper from software.
The record and each of its lists are JSON, twenty rows a page. No key needed for records and first pages, up to 100 calls a day. With a free key, your account gets 2,000 a day and every page.
GET https://conductscience.org/api/papers/v1/21656331
GET https://conductscience.org/api/papers/v1/21656331/references?page=2