Paper22400972
Reliability and validity of gait analysis by android-based smartphone.
Nishiguchi S and 13 others. Telemed J E Health, 2012. Cited by 112 papers, by iCite.
Cite this record
ConductScience Library. Reliability and validity of gait analysis by android-based smartphone. Papers, record 22400972. Release papers-2026-11-12-0.1.0, 12 Nov 2026. https://conductscience.org/library/papers/22400972
- Sources
- 11 sources
- Release
- papers-2026-11-12-0.1.0
Paper
PubMed's record of the paper, with iCite's citation figures. No abstract is shown.
Topics13
NLM's MeSH indexing of the paper, its major topics first.
| MeSH term | Major |
|---|---|
| Acceleration | Major topic |
| Gait | Major topic |
| Telemedicine | Major topic |
| Adolescent | |
| Adult | |
| Biomechanical Phenomena | |
| Female | |
| Humans | |
| Japan | |
| Male | |
| Reproducibility of Results | |
| Signal Processing, Computer-Assisted | |
| Young Adult |
Source PubMed
Trials1
The trials whose ClinicalTrials.gov record lists the paper, and the trial numbers the paper's PubMed record names.
| Trial | Title | The trial lists it as | Named in the paper's record |
|---|---|---|---|
| NCT03658915 | Validity and Reliability of Smartphone Use in Measuring Joint Position Sense in Patients With Knee Osteoarthritis | Background |
Source ClinicalTrials.gov
Cited by68
The papers in our copy of PubMed whose reference list names this one, newest first. iCite, which reads more sources, counts 112 citations.
| PMID | Title | Journal | Year | In Papers | Source |
|---|---|---|---|---|---|
| 42286488 | Identification of signal-based gait features and blood analytes associated with stroke status and walking speed in mild acute ischemic stroke. | BMC Neurol | 2026 | https://conductscience.org/library/papers/42286488 | PubMed |
| 41941370 | Validity of Smartphone-Based Measurement for Assessing Lower Limb Power for Sarcopenia and Frailty Discrimination: Cross-Sectional Study. | JMIR Form Res | 2026 | https://conductscience.org/library/papers/41941370 | PubMed |
| 40871922 | Real-Time Detection of Distracted Walking Using Smartphone IMU Sensors with Personalized and Emotion-Aware Modeling. | Sensors (Basel) | 2025 | https://conductscience.org/library/papers/40871922 | PubMed |
| 39686162 | Validity and Reliability of Gait Speed and Knee Flexion Estimated by a Novel Vision-Based Smartphone Application. | Sensors (Basel) | 2024 | https://conductscience.org/library/papers/39686162 | PubMed |
| 39213262 | Comparison of professional and everyday wearable technology at different body positions in terms of recording gait perturbations. | PLOS Digit Health | 2024 | https://conductscience.org/library/papers/39213262 | PubMed |
| 39140268 | A Novel Approach for Improving Gait Speed Estimation Using a Single Inertial Measurement Unit Embedded in a Smartphone: Validity and Reliability Study. | JMIR Mhealth Uhealth | 2024 | https://conductscience.org/library/papers/39140268 | PubMed |
| 38616288 | Validity of an android device for assessing mobility in people with chronic stroke and hemiparesis: a cross-sectional study. | J Neuroeng Rehabil | 2024 | https://conductscience.org/library/papers/38616288 | PubMed |
| 38534531 | Validity and Reliability of a Smartphone Application for Home Measurement of Four-Meter Gait Speed in Older Adults. | Bioengineering (Basel) | 2024 | https://conductscience.org/library/papers/38534531 | PubMed |
| 37896708 | A Scoping Review of the Validity and Reliability of Smartphone Accelerometers When Collecting Kinematic Gait Data. | Sensors (Basel) | 2023 | https://conductscience.org/library/papers/37896708 | PubMed |
| 37765801 | Gait Monitoring and Analysis: A Mathematical Approach. | Sensors (Basel) | 2023 | https://conductscience.org/library/papers/37765801 | PubMed |
| 37578611 | Validity and Reliability of Methods to Assess Movement Deficiencies Following Concussion: A COSMIN Systematic Review. | Sports Med Open | 2023 | https://conductscience.org/library/papers/37578611 | PubMed |
| 37514860 | The Reliability and Accuracy of a Fall Risk Assessment Procedure Using Mobile Smartphone Sensors Compared with a Physiological Profile Assessment. | Sensors (Basel) | 2023 | https://conductscience.org/library/papers/37514860 | PubMed |
| 37444772 | Comparative Analysis of Fall Risk Assessment Features in Community-Elderly and Stroke Survivors: Insights from Sensor-Based Data. | Healthcare (Basel) | 2023 | https://conductscience.org/library/papers/37444772 | PubMed |
| 37428666 | Association of Gait Quality With Daily-Life Mobility: An Actigraphy and Global Positioning System Based Analysis in Older Adults. | IEEE Trans Biomed Eng | 2024 | https://conductscience.org/library/papers/37428666 | PubMed |
| 37333459 | Classification of Parkinson's disease stages with a two-stage deep neural network. | Front Aging Neurosci | 2023 | https://conductscience.org/library/papers/37333459 | PubMed |
| 36616798 | Accelerometers in Our Pocket: Does Smartphone Accelerometer Technology Provide Accurate Data? | Sensors (Basel) | 2022 | https://conductscience.org/library/papers/36616798 | PubMed |
| 36232190 | Classification of Center of Mass Acceleration Patterns in Older People with Knee Osteoarthritis and Fear of Falling. | Int J Environ Res Public Health | 2022 | https://conductscience.org/library/papers/36232190 | PubMed |
| 35351019 | Impact of walking states, self-reported daily walking amount and age on the gait of older adults measured with a smart-phone app: a pilot study. | BMC Geriatr | 2022 | https://conductscience.org/library/papers/35351019 | PubMed |
| 35271066 | Deep Convolutional Neural Network-Based Hemiplegic Gait Detection Using an Inertial Sensor Located Freely in a Pocket. | Sensors (Basel) | 2022 | https://conductscience.org/library/papers/35271066 | PubMed |
| 35009667 | Validity and Reliability of a Smartphone App for Gait and Balance Assessment. | Sensors (Basel) | 2021 | https://conductscience.org/library/papers/35009667 | PubMed |
Data dates
The date of each source this release read.
- Trials
- 2026-11-12
- Gene search
- 2026-11-11
- Pipelines
- 2026-09-18
None in this release
- Grants
- Comments and corrections
- References
- Genes
- Drugs
- Data
Sources 11
- ChEMBL, through Open TargetsCC BY-SA 3.0
- ClinicalTrials.govNo license stated
- HGNCCC0
- iCiteCC BY 4.0
- NCBI GenePublic domain (US government)
- NIH RePORTER's grant and paper linksPublic domain
- Open TargetsCC0 1.0
- PMC's ID filePublic domain (US government)
- PubMedNLM's terms
- PubTator 3Public domain
- UniProtCC BY 4.0
Each source's terms
- ChEMBL, through Open TargetsCC BY-SA 3.0, for the parts from ChEMBL. Read on 8 Nov 2026 at https://platform-docs.opentargets.org/licence
- ClinicalTrials.govnone stated
- HGNCCC0: https://www.genenames.org/about/license/
- iCiteCC BY 4.0
- NCBI GeneNone named for the file. NCBI says information created by or for the US government on its site is in the public domain, and asks that NLM be acknowledged: https://www.ncbi.nlm.nih.gov/home/about/policies/
- NIH RePORTER's grant and paper linksPublic domain (NIH RePORTER)
- Open TargetsCC0 1.0. Open Targets asks that users cite its latest paper: Buniello et al. 2025, Open Targets Platform: facilitating therapeutic hypotheses building in drug discovery, Nucleic Acids Research 53(D1):D1467, PMID 39657122. Read on 8 Nov 2026 at https://platform-docs.opentargets.org/licence
- PMC's ID fileNone named for the file. NCBI says information created by or for the US government on its site is in the public domain, and asks that NLM be acknowledged: https://www.ncbi.nlm.nih.gov/home/about/policies/
- PubMedNLM's terms
- PubTator 3Public domain
- UniProtCC BY 4.0. UniProt's licence file: "All databases and documents in the UniProt FTP directory may be copied and redistributed freely, without advance permission, provided that this copyright statement is reproduced with each copy." UniProt asks that users cite its latest paper: The UniProt Consortium, UniProt: the Universal Protein Knowledgebase in 2025, Nucleic Acids Research 53:D609-D617, https://doi.org/10.1093/nar/gkae1010. Read on 9 Nov 2026 at https://www.uniprot.org/help/license
ClinicalTrials.gov's data carry an international copyright outside the United States: https://clinicaltrials.gov/about-site/terms-conditions.
For software
Read this paper from software.
The record and each of its lists are JSON, twenty rows a page. No key needed for records and first pages, up to 100 calls a day. With a free key, your account gets 2,000 a day and every page.
GET https://conductscience.org/api/papers/v1/22400972
GET https://conductscience.org/api/papers/v1/22400972/cited_by?page=2