Paper23831714
Improved diffuse fluorescence flow cytometer prototype for high sensitivity detection of rare circulating cells in vivo.
Pestana N and 6 others. J Biomed Opt, 2013. Cited by 8 papers, by iCite.
Cite this record
ConductScience Library. Improved diffuse fluorescence flow cytometer prototype for high sensitivity detection of rare circulating cells in vivo. Papers, record 23831714. Release papers-2026-11-12-0.1.0, 12 Nov 2026. https://conductscience.org/library/papers/23831714
- Sources
- 11 sources
- Release
- papers-2026-11-12-0.1.0
Paper
PubMed's record of the paper, with iCite's citation figures. No abstract is shown.
Topics11
NLM's MeSH indexing of the paper, its major topics first.
| MeSH term | Major |
|---|---|
| Flow Cytometry | Major topic |
| Optical Imaging | Major topic |
| Animals | |
| Fluorescent Dyes | |
| Mesenchymal Stem Cells | |
| Mice | |
| Mice, Nude | |
| Microspheres | |
| Phantoms, Imaging | |
| Sensitivity and Specificity | |
| Signal-To-Noise Ratio |
Source PubMed
Grants3
Each grant PubMed's record writes, matched to the NIH project NIH's grant and paper links name for this paper, and each of those links the record does not write.
| Grant, as the record writes it | Agency | Country | NIH project | Stated by | Source |
|---|---|---|---|---|---|
| P41 EB015903 | NIBIB NIH HHS | United States | P41EB015903 | PubMed and NIH | NIH RePORTER |
| R21 HL098750 | NHLBI NIH HHS | United States | R21HL098750 | PubMed and NIH | NIH RePORTER |
| 5R21HL098750 | NHLBI NIH HHS | United States | R21HL098750 | PubMed and NIH | NIH RePORTER |
References16
The papers the reference list in PubMed's record names, those in our copy of PubMed, in the list's order.
| Order | PMID | Title | Journal | Year | In Papers | Source |
|---|---|---|---|---|---|---|
| 1 | 19826056 | In vivo, noninvasive, label-free detection and eradication of circulating metastatic melanoma cells using two-color photoacoustic flow cytometry with a diode laser. | Cancer Res | 2009 | https://conductscience.org/library/papers/19826056 | PubMed |
| 2 | 15289300 | In vivo flow cytometry: a new method for enumerating circulating cancer cells. | Cancer Res | 2004 | https://conductscience.org/library/papers/15289300 | PubMed |
| 3 | 15065171 | Time-of-flight quantitative measurements of blood flow in mouse hindlimbs. | J Magn Reson Imaging | 2004 | https://conductscience.org/library/papers/15065171 | PubMed |
| 4 | 22889108 | Persistence of disseminated tumor cells after neoadjuvant treatment for locally advanced breast cancer predicts poor survival. | Breast Cancer Res | 2012 | https://conductscience.org/library/papers/22889108 | PubMed |
| 5 | 22502573 | Instrument for fluorescence sensing of circulating cells with diffuse light in mice in vivo. | J Biomed Opt | 2012 | https://conductscience.org/library/papers/22502573 | PubMed |
| 6 | 18253104 | Metastasis: a therapeutic target for cancer. | Nat Clin Pract Oncol | 2008 | https://conductscience.org/library/papers/18253104 | PubMed |
| 7 | 22750660 | Tomographic sensing and localization of fluorescently labeled circulating cells in mice in vivo. | Phys Med Biol | 2012 | https://conductscience.org/library/papers/22750660 | PubMed |
| 8 | 22394600 | Hypoxia promotes dissemination of multiple myeloma through acquisition of epithelial to mesenchymal transition-like features. | Blood | 2012 | https://conductscience.org/library/papers/22394600 | PubMed |
| 9 | 22454286 | Real-time monitoring of rare circulating hepatocellular carcinoma cells in an orthotopic model by in vivo flow cytometry assesses resection on metastasis. | Cancer Res | 2012 | https://conductscience.org/library/papers/22454286 | PubMed |
| 10 | 16292946 | Integrated photothermal flow cytometry in vivo. | J Biomed Opt | 2005 | https://conductscience.org/library/papers/16292946 | PubMed |
| 11 | 19483816 | Motion artifacts in optical coherence tomography with frequency-domain ranging. | Opt Express | 2004 | https://conductscience.org/library/papers/19483816 | PubMed |
| 12 | 19547203 | Development of fluorescent materials for Diffuse Fluorescence Tomography standards and phantoms. | Opt Express | 2007 | https://conductscience.org/library/papers/19547203 | PubMed |
| 13 | 17721542 | Bright far-red fluorescent protein for whole-body imaging. | Nat Methods | 2007 | https://conductscience.org/library/papers/17721542 | PubMed |
| 14 | 21905206 | Cell labeling approaches for fluorescence-based in vivo flow cytometry. | Cytometry A | 2011 | https://conductscience.org/library/papers/21905206 | PubMed |
| 15 | 19052546 | Live-animal tracking of individual haematopoietic stem/progenitor cells in their niche. | Nature | 2009 | https://conductscience.org/library/papers/19052546 | PubMed |
| 16 | 22749928 | Photoacoustic flow cytometry. | Methods | 2012 | https://conductscience.org/library/papers/22749928 | PubMed |
Cited by7
The papers in our copy of PubMed whose reference list names this one, newest first. iCite, which reads more sources, counts 8 citations.
| PMID | Title | Journal | Year | In Papers | Source |
|---|---|---|---|---|---|
| 39508030 | Prospects for Fluorescence Molecular In Vivo Liquid Biopsy of Circulating Tumor Cells in Humans. | Front Photon | 2022 | https://conductscience.org/library/papers/39508030 | PubMed |
| 33240820 | Short-Term Circulating Tumor Cell Dynamics in Mouse Xenograft Models and Implications for Liquid Biopsy. | Front Oncol | 2020 | https://conductscience.org/library/papers/33240820 | PubMed |
| 32210561 | Prospects for the Use of Upconverting Nanoparticles as a Contrast Agent for Enumeration of Circulating Cells in vivo. | Int J Nanomedicine | 2020 | https://conductscience.org/library/papers/32210561 | PubMed |
| 30508273 | Detection of Apoptotic Circulating Tumor Cells Using in vivo Fluorescence Flow Cytometry. | Cytometry A | 2019 | https://conductscience.org/library/papers/30508273 | PubMed |
| 29240559 | Fluorescence detection, enumeration and characterization of single circulating cells in vivo: technology, applications and future prospects. | Phys Med Biol | 2017 | https://conductscience.org/library/papers/29240559 | PubMed |
| 28290598 | Diffuse fluorescence fiber probe for in vivo detection of circulating cells. | J Biomed Opt | 2017 | https://conductscience.org/library/papers/28290598 | PubMed |
| 25822954 | Performance of computer vision in vivo flow cytometry with low fluorescence contrast. | J Biomed Opt | 2015 | https://conductscience.org/library/papers/25822954 | PubMed |
Data dates
The date of each source this release read.
- Trials
- 2026-11-12
- Gene search
- 2026-11-11
- Pipelines
- 2026-09-18
None in this release
- Trials
- Comments and corrections
- Genes
- Drugs
- Data
Sources 11
- ChEMBL, through Open TargetsCC BY-SA 3.0
- ClinicalTrials.govNo license stated
- HGNCCC0
- iCiteCC BY 4.0
- NCBI GenePublic domain (US government)
- NIH RePORTER's grant and paper linksPublic domain
- Open TargetsCC0 1.0
- PMC's ID filePublic domain (US government)
- PubMedNLM's terms
- PubTator 3Public domain
- UniProtCC BY 4.0
Each source's terms
- ChEMBL, through Open TargetsCC BY-SA 3.0, for the parts from ChEMBL. Read on 8 Nov 2026 at https://platform-docs.opentargets.org/licence
- ClinicalTrials.govnone stated
- HGNCCC0: https://www.genenames.org/about/license/
- iCiteCC BY 4.0
- NCBI GeneNone named for the file. NCBI says information created by or for the US government on its site is in the public domain, and asks that NLM be acknowledged: https://www.ncbi.nlm.nih.gov/home/about/policies/
- NIH RePORTER's grant and paper linksPublic domain (NIH RePORTER)
- Open TargetsCC0 1.0. Open Targets asks that users cite its latest paper: Buniello et al. 2025, Open Targets Platform: facilitating therapeutic hypotheses building in drug discovery, Nucleic Acids Research 53(D1):D1467, PMID 39657122. Read on 8 Nov 2026 at https://platform-docs.opentargets.org/licence
- PMC's ID fileNone named for the file. NCBI says information created by or for the US government on its site is in the public domain, and asks that NLM be acknowledged: https://www.ncbi.nlm.nih.gov/home/about/policies/
- PubMedNLM's terms
- PubTator 3Public domain
- UniProtCC BY 4.0. UniProt's licence file: "All databases and documents in the UniProt FTP directory may be copied and redistributed freely, without advance permission, provided that this copyright statement is reproduced with each copy." UniProt asks that users cite its latest paper: The UniProt Consortium, UniProt: the Universal Protein Knowledgebase in 2025, Nucleic Acids Research 53:D609-D617, https://doi.org/10.1093/nar/gkae1010. Read on 9 Nov 2026 at https://www.uniprot.org/help/license
ClinicalTrials.gov's data carry an international copyright outside the United States: https://clinicaltrials.gov/about-site/terms-conditions.
For software
Read this paper from software.
The record and each of its lists are JSON, twenty rows a page. No key needed for records and first pages, up to 100 calls a day. With a free key, your account gets 2,000 a day and every page.
GET https://conductscience.org/api/papers/v1/23831714
GET https://conductscience.org/api/papers/v1/23831714/authors