Paper28595331
The Use of Single Stent-Assisted Coiling in Treatment of Bifurcation Aneurysms: A Multicenter Cohort Study With Proposal of a Scoring System to Predict Complete Occlusion.
Adeeb N and 10 others. Neurosurgery, 2018. Cited by 25 papers, by iCite.
Cite this record
ConductScience Library. The Use of Single Stent-Assisted Coiling in Treatment of Bifurcation Aneurysms: A Multicenter Cohort Study With Proposal of a Scoring System to Predict Complete Occlusion. Papers, record 28595331. Release papers-2026-11-12-0.1.0, 12 Nov 2026. https://conductscience.org/library/papers/28595331
- Sources
- 11 sources
- Release
- papers-2026-11-12-0.1.0
Paper
PubMed's record of the paper, with iCite's citation figures. No abstract is shown.
- Title
- The Use of Single Stent-Assisted Coiling in Treatment of Bifurcation Aneurysms: A Multicenter Cohort Study With Proposal of a Scoring System to Predict Complete Occlusion.
- PubMed
Topics6
NLM's MeSH indexing of the paper, its major topics first.
| MeSH term | Major |
|---|---|
| Embolization, Therapeutic | Major topic |
| Intracranial Aneurysm | Major topic |
| Cerebral Angiography | |
| Humans | |
| Retrospective Studies | |
| Stents |
Source PubMed
Cited by13
The papers in our copy of PubMed whose reference list names this one, newest first. iCite, which reads more sources, counts 25 citations.
| PMID | Title | Journal | Year | In Papers | Source |
|---|---|---|---|---|---|
| 41612108 | Comparison of flow diverters versus stent-assisted coiling in unruptured anterior circulation bifurcation aneurysms: a two-center, propensity score matched study. | Neurosurg Rev | 2026 | https://conductscience.org/library/papers/41612108 | PubMed |
| 40696186 | Delayed aneurysm occlusion after single stent-assisted coiling: factors in initially incompletely occluded unruptured intracranial aneurysms. | Neurosurg Rev | 2025 | https://conductscience.org/library/papers/40696186 | PubMed |
| 39467927 | The Woven EndoBridge device as a good alternative treatment for stent assisted coiling in intracranial bifurcation aneurysms: a systematic review and meta-analysis. | Neurosurg Rev | 2024 | https://conductscience.org/library/papers/39467927 | PubMed |
| 38622821 | Stent plus balloon-assisted coiling with low-profile braided stents in the treatment of complex wide-necked intracranial bifurcation aneurysms. | Neuroradiol J | 2024 | https://conductscience.org/library/papers/38622821 | PubMed |
| 38503965 | Efficacy and safety of low profile stents in Y-stent assisted coil embolization of wide-necked bifurcation aneurysms: a systematic review and meta-analysis. | Neurosurg Rev | 2024 | https://conductscience.org/library/papers/38503965 | PubMed |
| 37940387 | Anterior circulation location-specific results for stent-assisted coiling - carotid versus distal aneurysms: 1-year outcomes from the Neuroform Atlas Stent Pivotal Trial. | J Neurointerv Surg | 2024 | https://conductscience.org/library/papers/37940387 | PubMed |
| 36247783 | Efficacy of pipeline embolization device vs. traditional coils in embolization of intracranial aneurysms: A systematic review and meta-analysis. | Front Neurol | 2022 | https://conductscience.org/library/papers/36247783 | PubMed |
| 35234080 | Comparison of Solitaire and Neuroform Stenting for Coiling of Intracranial Bifurcation Aneurysms. | Interv Neuroradiol | 2023 | https://conductscience.org/library/papers/35234080 | PubMed |
| 35211076 | Hemodynamic Effects of Stent-Induced Straightening of Parent Artery vs. Stent Struts for Intracranial Bifurcation Aneurysms. | Front Neurol | 2021 | https://conductscience.org/library/papers/35211076 | PubMed |
| 34879639 | Long-Term Outcomes of Placement of a Single Transverse Stent through the Anterior Communicating Artery via the Nondominant A1 in Coil Embolization of Wide-Necked Anterior Communicating Artery Aneurysms. | J Korean Neurosurg Soc | 2022 | https://conductscience.org/library/papers/34879639 | PubMed |
| 33222557 | Analysis of branch artery orifice angulation: Feasibility of the shelf technique for the treatment of wide-neck bifurcation aneurysms. | Interv Neuroradiol | 2021 | https://conductscience.org/library/papers/33222557 | PubMed |
| 30998116 | No differences in effectiveness and safety between pipeline embolization device and stent-assisted coiling for the treatment of communicating segment internal carotid artery aneurysms. | Neuroradiol J | 2019 | https://conductscience.org/library/papers/30998116 | PubMed |
| 29051205 | Two-Center Experience in the Endovascular Treatment of Ruptured and Unruptured Intracranial Aneurysms Using the WEB Device: A Retrospective Analysis. | AJNR Am J Neuroradiol | 2018 | https://conductscience.org/library/papers/29051205 | PubMed |
Data dates
The date of each source this release read.
- Trials
- 2026-11-12
- Gene search
- 2026-11-11
- Pipelines
- 2026-09-18
None in this release
- Grants
- Trials
- Comments and corrections
- References
- Genes
- Drugs
- Data
Sources 11
- ChEMBL, through Open TargetsCC BY-SA 3.0
- ClinicalTrials.govNo license stated
- HGNCCC0
- iCiteCC BY 4.0
- NCBI GenePublic domain (US government)
- NIH RePORTER's grant and paper linksPublic domain
- Open TargetsCC0 1.0
- PMC's ID filePublic domain (US government)
- PubMedNLM's terms
- PubTator 3Public domain
- UniProtCC BY 4.0
Each source's terms
- ChEMBL, through Open TargetsCC BY-SA 3.0, for the parts from ChEMBL. Read on 8 Nov 2026 at https://platform-docs.opentargets.org/licence
- ClinicalTrials.govnone stated
- HGNCCC0: https://www.genenames.org/about/license/
- iCiteCC BY 4.0
- NCBI GeneNone named for the file. NCBI says information created by or for the US government on its site is in the public domain, and asks that NLM be acknowledged: https://www.ncbi.nlm.nih.gov/home/about/policies/
- NIH RePORTER's grant and paper linksPublic domain (NIH RePORTER)
- Open TargetsCC0 1.0. Open Targets asks that users cite its latest paper: Buniello et al. 2025, Open Targets Platform: facilitating therapeutic hypotheses building in drug discovery, Nucleic Acids Research 53(D1):D1467, PMID 39657122. Read on 8 Nov 2026 at https://platform-docs.opentargets.org/licence
- PMC's ID fileNone named for the file. NCBI says information created by or for the US government on its site is in the public domain, and asks that NLM be acknowledged: https://www.ncbi.nlm.nih.gov/home/about/policies/
- PubMedNLM's terms
- PubTator 3Public domain
- UniProtCC BY 4.0. UniProt's licence file: "All databases and documents in the UniProt FTP directory may be copied and redistributed freely, without advance permission, provided that this copyright statement is reproduced with each copy." UniProt asks that users cite its latest paper: The UniProt Consortium, UniProt: the Universal Protein Knowledgebase in 2025, Nucleic Acids Research 53:D609-D617, https://doi.org/10.1093/nar/gkae1010. Read on 9 Nov 2026 at https://www.uniprot.org/help/license
ClinicalTrials.gov's data carry an international copyright outside the United States: https://clinicaltrials.gov/about-site/terms-conditions.
For software
Read this paper from software.
The record and each of its lists are JSON, twenty rows a page. No key needed for records and first pages, up to 100 calls a day. With a free key, your account gets 2,000 a day and every page.
GET https://conductscience.org/api/papers/v1/28595331
GET https://conductscience.org/api/papers/v1/28595331/authors