Paper29318142
Mechanical Characterisation and Biomechanical and Biological Behaviours of Ti-Zr Binary-Alloy Dental Implants.
Brizuela-Velasco A and 8 others. Biomed Res Int, 2017. Cited by 31 papers, by iCite.
Cite this record
ConductScience Library. Mechanical Characterisation and Biomechanical and Biological Behaviours of Ti-Zr Binary-Alloy Dental Implants. Papers, record 29318142. Release papers-2026-11-12-0.1.0, 12 Nov 2026. https://conductscience.org/library/papers/29318142
- Sources
- 11 sources
- Release
- papers-2026-11-12-0.1.0
Paper
PubMed's record of the paper, with iCite's citation figures. No abstract is shown.
- Title
- Mechanical Characterisation and Biomechanical and Biological Behaviours of Ti-Zr Binary-Alloy Dental Implants.
- PubMed
Topics8
NLM's MeSH indexing of the paper, its major topics first.
| MeSH term | Major |
|---|---|
| Alloys | Major topic |
| Dental Implants | Major topic |
| Materials Testing | Major topic |
| Stress, Mechanical | Major topic |
| Animals | |
| Finite Element Analysis | |
| Humans | |
| Rabbits |
Source PubMed
References32
The papers the reference list in PubMed's record names, those in our copy of PubMed, in the list's order.
| Order | PMID | Title | Journal | Year | In Papers | Source |
|---|---|---|---|---|---|---|
| 1 | 9590939 | Quantitative and qualitative investigations of surface enlarged titanium and titanium alloy implants. | Clin Oral Implants Res | 1998 | https://conductscience.org/library/papers/9590939 | PubMed |
| 2 | 9916767 | Zirconia as a ceramic biomaterial. | Biomaterials | 1999 | https://conductscience.org/library/papers/9916767 | PubMed |
| 3 | 9619438 | Timing of loading and effect of micromotion on bone-dental implant interface: review of experimental literature. | J Biomed Mater Res | 1998 | https://conductscience.org/library/papers/9619438 | PubMed |
| 4 | 12901992 | Weibull analysis and flexural strength of hot-pressed core and veneered ceramic structures. | Dent Mater | 2003 | https://conductscience.org/library/papers/12901992 | PubMed |
| 5 | 22492019 | Bone apposition to a titanium-zirconium alloy implant, as compared to two other titanium-containing implants. | Eur Cell Mater | 2012 | https://conductscience.org/library/papers/22492019 | PubMed |
| 6 | 11404759 | Application of finite element analysis in implant dentistry: a review of the literature. | J Prosthet Dent | 2001 | https://conductscience.org/library/papers/11404759 | PubMed |
| 7 | 8468083 | The biomechanics of force distribution in implant-supported prostheses. | Int J Oral Maxillofac Implants | 1993 | https://conductscience.org/library/papers/8468083 | PubMed |
| 8 | 15790383 | Influence of marginal bone resorption on stress around an implant--a three-dimensional finite element analysis. | J Oral Rehabil | 2005 | https://conductscience.org/library/papers/15790383 | PubMed |
| 9 | 8957790 | Three-dimensional finite element analysis of stress-distribution around single tooth implants as a function of bony support, prosthesis type, and loading during function. | J Prosthet Dent | 1996 | https://conductscience.org/library/papers/8957790 | PubMed |
| 10 | 23062126 | Systematic review of the survival rate and the biological, technical, and aesthetic complications of fixed dental prostheses with cantilevers on implants reported in longitudinal studies with a mean of 5 years follow-up. | Clin Oral Implants Res | 2012 | https://conductscience.org/library/papers/23062126 | PubMed |
| 11 | 28626888 | Clinical and radiographic evaluation of early loaded narrow-diameter implants: 5-year follow-up of a multicenter prospective clinical study. | Clin Oral Implants Res | 2017 | https://conductscience.org/library/papers/28626888 | PubMed |
| 12 | 27995137 | Biomechanical Consequences of the Elastic Properties of Dental Implant Alloys on the Supporting Bone: Finite Element Analysis. | Biomed Res Int | 2016 | https://conductscience.org/library/papers/27995137 | PubMed |
| 13 | 27063944 | Evaluation of stress distributions occurring on zirconia and titanium implant-supported prostheses: A three-dimensional finite element analysis. | J Prosthet Dent | 2016 | https://conductscience.org/library/papers/27063944 | PubMed |
| 14 | 27258932 | Microstructure and mechanical properties of Ti-15Zr alloy used as dental implant material. | J Mech Behav Biomed Mater | 2016 | https://conductscience.org/library/papers/27258932 | PubMed |
| 15 | 27637478 | Trends in techniques to avoid bone augmentation surgery: Application of short implants, narrow-diameter implants and guided surgery. | J Craniomaxillofac Surg | 2016 | https://conductscience.org/library/papers/27637478 | PubMed |
| 16 | 9638001 | A quantitative comparison of machined commercially pure titanium and titanium-aluminum-vanadium implants in rabbit bone. | Int J Oral Maxillofac Implants | 1998 | https://conductscience.org/library/papers/9638001 | PubMed |
| 17 | 28787980 | A Critical Review of Dental Implant Materials with an Emphasis on Titanium versus Zirconia. | Materials (Basel) | 2015 | https://conductscience.org/library/papers/28787980 | PubMed |
| 18 | 24656363 | Interaction of bone-dental implant with new ultra low modulus alloy using a numerical approach. | Mater Sci Eng C Mater Biol Appl | 2014 | https://conductscience.org/library/papers/24656363 | PubMed |
| 19 | 23748329 | Stress distribution in the abutment and retention screw of a single implant supporting a prosthesis with platform switching. | Int J Oral Maxillofac Implants | 2013 | https://conductscience.org/library/papers/23748329 | PubMed |
| 20 | 23905841 | The influence of implant diameter on its survival: a meta-analysis based on prospective clinical trials. | J Periodontol | 2014 | https://conductscience.org/library/papers/23905841 | PubMed |
Cited by25
The papers in our copy of PubMed whose reference list names this one, newest first. iCite, which reads more sources, counts 31 citations.
| PMID | Title | Journal | Year | In Papers | Source |
|---|---|---|---|---|---|
| 42598652 | Analysis of stress distribution around conventional and basal dental implants in the posterior mandible: A finite element study. | J Indian Soc Periodontol | 2026 | https://conductscience.org/library/papers/42598652 | PubMed |
| 42519295 | Biomechanical evaluation of narrow-diameter Ti-Zr implant systems at different lingual inclination angles in the molar region. | Front Oral Health | 2026 | https://conductscience.org/library/papers/42519295 | PubMed |
| 42506537 | Biomechanical Evaluation of Ultra-Short Posterior Implants as Adjuncts to Two-Implant Mandibular Overdentures in the Atrophic Edentulous Mandible: A Three-Dimensional Finite Element Analysis Study. | J Funct Biomater | 2026 | https://conductscience.org/library/papers/42506537 | PubMed |
| 42505504 | Biomimetic Surface Engineering of Ti-15Zr (Roxolid™) Implants: Enhancing Osseointegration and Bone Regeneration-A Comprehensive Review. | Biomimetics (Basel) | 2026 | https://conductscience.org/library/papers/42505504 | PubMed |
| 41744927 | Influence of Chemical Composition on the Physical-Mechanical Properties of Some Experimental Titanium Alloys for Dental Implants. | Dent J (Basel) | 2026 | https://conductscience.org/library/papers/41744927 | PubMed |
| 41590787 | Biomechanical Effects of Platform Diameter and Screw Length in an Abutment-Free Tissue-Level Implant System Compared with a Ti-Base Configuration: 3D Finite Element Analysis. | J Funct Biomater | 2025 | https://conductscience.org/library/papers/41590787 | PubMed |
| 41590130 | Biocompatibility Evaluation of Novel Experimental Titanium Alloys for Dental Implants. | Dent J (Basel) | 2025 | https://conductscience.org/library/papers/41590130 | PubMed |
| 41543814 | Mechanical effects of taper angles in implant-abutment connection: a finite element study. | Int J Implant Dent | 2026 | https://conductscience.org/library/papers/41543814 | PubMed |
| 41221458 | The impact of physiological and parafunctional posterior occlusal forces on experimental Ti-15Zrsupracrestal dental implant - a finite element analysis. | Med Pharm Rep | 2025 | https://conductscience.org/library/papers/41221458 | PubMed |
| 41203695 | In vitro evaluation of biocompatibility of Ti-20Zr-3Mo-3Sn β-alloy for oral implantology. | Sci Rep | 2025 | https://conductscience.org/library/papers/41203695 | PubMed |
| 41149718 | Stress Assessment of Abutment-Free and Three Implant-Abutment Connections Utilizing Various Abutment Materials: A 3D Finite Element Study of Static and Cyclic Static Loading Conditions. | J Funct Biomater | 2025 | https://conductscience.org/library/papers/41149718 | PubMed |
| 40802268 | Cone Beam Computed Tomography-Based Finite Element Analysis of Bone-Implant Constructs and Comparison With Experimental Measurements. | J Biomech Eng | 2025 | https://conductscience.org/library/papers/40802268 | PubMed |
| 40033565 | Finite element analysis of primary healing implants with different transmucosal designs. | J Prosthodont | 2026 | https://conductscience.org/library/papers/40033565 | PubMed |
| 39124410 | Design Factors of Ti-Base Abutments Related to the Biomechanics Behavior of Dental Implant Prostheses: Finite Element Analysis and Validation via In Vitro Load Creeping Tests. | Materials (Basel) | 2024 | https://conductscience.org/library/papers/39124410 | PubMed |
| 38068127 | Dental Implants: Modern Materials and Methods of Their Surface Modification. | Materials (Basel) | 2023 | https://conductscience.org/library/papers/38068127 | PubMed |
| 36290451 | Finite Element Analysis of a New Non-Engaging Abutment System for Three-Unit Implant-Supported Fixed Dental Prostheses. | Bioengineering (Basel) | 2022 | https://conductscience.org/library/papers/36290451 | PubMed |
| 34772034 | Physicochemical and Biological Characterization of Ti6Al4V Particles Obtained by Implantoplasty: An In Vitro Study. Part I. | Materials (Basel) | 2021 | https://conductscience.org/library/papers/34772034 | PubMed |
| 33973645 | Osseointegration of a novel 3D porous Ti-6Al-4V implant material - Histomorphometric analysis in rabbits. | Histol Histopathol | 2021 | https://conductscience.org/library/papers/33973645 | PubMed |
| 33779981 | Sequential osseointegration from osseohealing to osseoremodeling - Histomorphological comparison of novel 3D porous and solid Ti-6Al-4V titanium implants. | Histol Histopathol | 2021 | https://conductscience.org/library/papers/33779981 | PubMed |
| 33485035 | Effects of implant buccal distance on peri-implant strain: A Micro-CT based finite element analysis. | J Mech Behav Biomed Mater | 2021 | https://conductscience.org/library/papers/33485035 | PubMed |
Data dates
The date of each source this release read.
- Trials
- 2026-11-12
- Gene search
- 2026-11-11
- Pipelines
- 2026-09-18
None in this release
- Grants
- Trials
- Comments and corrections
- Genes
- Drugs
- Data
Sources 11
- ChEMBL, through Open TargetsCC BY-SA 3.0
- ClinicalTrials.govNo license stated
- HGNCCC0
- iCiteCC BY 4.0
- NCBI GenePublic domain (US government)
- NIH RePORTER's grant and paper linksPublic domain
- Open TargetsCC0 1.0
- PMC's ID filePublic domain (US government)
- PubMedNLM's terms
- PubTator 3Public domain
- UniProtCC BY 4.0
Each source's terms
- ChEMBL, through Open TargetsCC BY-SA 3.0, for the parts from ChEMBL. Read on 8 Nov 2026 at https://platform-docs.opentargets.org/licence
- ClinicalTrials.govnone stated
- HGNCCC0: https://www.genenames.org/about/license/
- iCiteCC BY 4.0
- NCBI GeneNone named for the file. NCBI says information created by or for the US government on its site is in the public domain, and asks that NLM be acknowledged: https://www.ncbi.nlm.nih.gov/home/about/policies/
- NIH RePORTER's grant and paper linksPublic domain (NIH RePORTER)
- Open TargetsCC0 1.0. Open Targets asks that users cite its latest paper: Buniello et al. 2025, Open Targets Platform: facilitating therapeutic hypotheses building in drug discovery, Nucleic Acids Research 53(D1):D1467, PMID 39657122. Read on 8 Nov 2026 at https://platform-docs.opentargets.org/licence
- PMC's ID fileNone named for the file. NCBI says information created by or for the US government on its site is in the public domain, and asks that NLM be acknowledged: https://www.ncbi.nlm.nih.gov/home/about/policies/
- PubMedNLM's terms
- PubTator 3Public domain
- UniProtCC BY 4.0. UniProt's licence file: "All databases and documents in the UniProt FTP directory may be copied and redistributed freely, without advance permission, provided that this copyright statement is reproduced with each copy." UniProt asks that users cite its latest paper: The UniProt Consortium, UniProt: the Universal Protein Knowledgebase in 2025, Nucleic Acids Research 53:D609-D617, https://doi.org/10.1093/nar/gkae1010. Read on 9 Nov 2026 at https://www.uniprot.org/help/license
ClinicalTrials.gov's data carry an international copyright outside the United States: https://clinicaltrials.gov/about-site/terms-conditions.
For software
Read this paper from software.
The record and each of its lists are JSON, twenty rows a page. No key needed for records and first pages, up to 100 calls a day. With a free key, your account gets 2,000 a day and every page.
GET https://conductscience.org/api/papers/v1/29318142
GET https://conductscience.org/api/papers/v1/29318142/references?page=2