Free-Breathing and Ungated Dynamic MRI Using Navigator-Less Spiral SToRM.
Ahmed AH and 5 others. IEEE Trans Med Imaging, 2020. Cited by 18 papers, by iCite.
Cite this record
ConductScience Library. Free-Breathing and Ungated Dynamic MRI Using Navigator-Less Spiral SToRM. Papers, record 32746136. Release papers-2026-11-12-0.1.0, 12 Nov 2026. https://conductscience.org/library/papers/32746136
- Sources
- 11 sources
- Release
- papers-2026-11-12-0.1.0
Paper
PubMed's record of the paper, with iCite's citation figures. No abstract is shown.
Topics8
NLM's MeSH indexing of the paper, its major topics first.
| MeSH term | Major |
|---|---|
| Magnetic Resonance Imaging | Major topic |
| Respiration | Major topic |
| Algorithms | |
| Artifacts | |
| Breath Holding | |
| Heart | |
| Image Processing, Computer-Assisted | |
| Magnetic Resonance Imaging, Cine |
Source PubMed
Grants5
Each grant PubMed's record writes, matched to the NIH project NIH's grant and paper links name for this paper, and each of those links the record does not write.
| Grant, as the record writes it | Agency | Country | NIH project | Stated by | Source |
|---|---|---|---|---|---|
| R01 EB019961 | NIBIB NIH HHS | United States | R01EB019961 | PubMed and NIH | NIH RePORTER |
| S10 OD025025 | NIH HHS | United States | S10OD025025 | PubMed and NIH | NIH RePORTER |
| R01 HL131919 | NHLBI NIH HHS | United States | R01HL131919 | PubMed and NIH | NIH RePORTER |
| T32 GM007337 | NIGMS NIH HHS | United States | T32GM007337 | PubMed | NIH RePORTER |
| DP1 OD003819 | NIH HHS | United States | DP1OD003819 | PubMed | NIH RePORTER |
References26
The papers the reference list in PubMed's record names, those in our copy of PubMed, in the list's order.
| Order | PMID | Title | Journal | Year | In Papers | Source |
|---|---|---|---|---|---|---|
| 1 | 7995705 | Breath-holding capability of adults. Implications for spiral computed tomography, fast-acquisition magnetic resonance imaging, and angiography. | Invest Radiol | 1994 | https://conductscience.org/library/papers/7995705 | PubMed |
| 2 | 19780155 | High spatial and temporal resolution cardiac cine MRI from retrospective reconstruction of data acquired in real time using motion correction and resorting. | Magn Reson Med | 2009 | https://conductscience.org/library/papers/19780155 | PubMed |
| 3 | 33768137 | Manifold recovery using kernel low-rank regularization: application to dynamic imaging. | IEEE Trans Comput Imaging | 2019 | https://conductscience.org/library/papers/33768137 | PubMed |
| 4 | 10800033 | Adaptive reconstruction of phased array MR imagery. | Magn Reson Med | 2000 | https://conductscience.org/library/papers/10800033 | PubMed |
| 5 | 26685228 | Dynamic MRI Using SmooThness Regularization on Manifolds (SToRM). | IEEE Trans Med Imaging | 2016 | https://conductscience.org/library/papers/26685228 | PubMed |
| 6 | 24760724 | Low-rank plus sparse matrix decomposition for accelerated dynamic MRI with separation of background and dynamic components. | Magn Reson Med | 2015 | https://conductscience.org/library/papers/24760724 | PubMed |
| 7 | 21292593 | Accelerated dynamic MRI exploiting sparsity and low-rank structure: k-t SLR. | IEEE Trans Med Imaging | 2011 | https://conductscience.org/library/papers/21292593 | PubMed |
| 8 | 29035212 | A Deep Cascade of Convolutional Neural Networks for Dynamic MR Image Reconstruction. | IEEE Trans Med Imaging | 2018 | https://conductscience.org/library/papers/29035212 | PubMed |
| 9 | 29386056 | Simple motion correction strategy reduces respiratory-induced motion artifacts for k-t accelerated and compressed-sensing cardiovascular magnetic resonance perfusion imaging. | J Cardiovasc Magn Reson | 2018 | https://conductscience.org/library/papers/29386056 | PubMed |
| 10 | 23542951 | Blind compressive sensing dynamic MRI. | IEEE Trans Med Imaging | 2013 | https://conductscience.org/library/papers/23542951 | PubMed |
| 11 | 22695345 | Image reconstruction from highly undersampled (k, t)-space data with joint partial separability and sparsity constraints. | IEEE Trans Med Imaging | 2012 | https://conductscience.org/library/papers/22695345 | PubMed |
| 12 | 23132400 | Motion-adaptive spatio-temporal regularization for accelerated dynamic MRI. | Magn Reson Med | 2013 | https://conductscience.org/library/papers/23132400 | PubMed |
| 13 | 25960254 | Non-Cartesian balanced steady-state free precession pulse sequences for real-time cardiac MRI. | Magn Reson Med | 2016 | https://conductscience.org/library/papers/25960254 | PubMed |
| 14 | 31403408 | Bi-Linear Modeling of Data Manifolds for Dynamic-MRI Recovery. | IEEE Trans Med Imaging | 2020 | https://conductscience.org/library/papers/31403408 | PubMed |
| 15 | 17326164 | Whole-heart cine MRI using real-time respiratory self-gating. | Magn Reson Med | 2007 | https://conductscience.org/library/papers/17326164 | PubMed |
| 16 | 27093543 | Accelerated High-Dimensional MR Imaging With Sparse Sampling Using Low-Rank Tensors. | IEEE Trans Med Imaging | 2016 | https://conductscience.org/library/papers/27093543 | PubMed |
| 17 | 18727100 | Free-breathing cine MRI. | Magn Reson Med | 2008 | https://conductscience.org/library/papers/18727100 | PubMed |
| 18 | 31006916 | Free-breathing cine imaging with motion-corrected reconstruction at 3T using SPiral Acquisition with Respiratory correction and Cardiac Self-gating (SPARCS). | Magn Reson Med | 2019 | https://conductscience.org/library/papers/31006916 | PubMed |
| 19 | 18777547 | 2D free-breathing dual navigator-gated cardiac function validated against the 2D breath-hold acquisition. | J Magn Reson Imaging | 2008 | https://conductscience.org/library/papers/18777547 | PubMed |
| 20 | 26148753 | Golden ratio sparse MRI using tiny golden angles. | Magn Reson Med | 2016 | https://conductscience.org/library/papers/26148753 | PubMed |
Cited by14
The papers in our copy of PubMed whose reference list names this one, newest first. iCite, which reads more sources, counts 18 citations.
| PMID | Title | Journal | Year | In Papers | Source |
|---|---|---|---|---|---|
| 41994176 | Spatiotemporal Gaussian representation-based dynamic reconstruction and motion estimation framework for time-resolved volumetric MR imaging (DREME-GSMR). | ArXiv | 2026 | https://conductscience.org/library/papers/41994176 | PubMed |
| 41827268 | Glycolic Acid-Guided Intelligent Neurovascular Imaging: A Cross-Scale Platform for Real-Time Neuroprotection and Adaptive Stroke Imaging. | J Clin Med | 2026 | https://conductscience.org/library/papers/41827268 | PubMed |
| 40760871 | Multifrequency Time-Dependent Deep Image Prior for Real-Time Free-Breathing Cardiac Imaging. | NMR Biomed | 2025 | https://conductscience.org/library/papers/40760871 | PubMed |
| 40442341 | Free-running isotropic three-dimensional cine magnetic resonance imaging with deep learning image reconstruction. | Pediatr Radiol | 2025 | https://conductscience.org/library/papers/40442341 | PubMed |
| 39638149 | Feasibility of fetal cardiac function and anatomy assessment by real-time spiral balanced steady-state free precession magnetic resonance imaging at 0.55T. | J Cardiovasc Magn Reson | 2025 | https://conductscience.org/library/papers/39638149 | PubMed |
| 39042206 | Deep learning for accelerated and robust MRI reconstruction. | MAGMA | 2024 | https://conductscience.org/library/papers/39042206 | PubMed |
| 37799087 | HyperSLICE: HyperBand optimized spiral for low-latency interactive cardiac examination. | Magn Reson Med | 2024 | https://conductscience.org/library/papers/37799087 | PubMed |
| 36121938 | Manifold Learning via Linear Tangent Space Alignment (LTSA) for Accelerated Dynamic MRI With Sparse Sampling. | IEEE Trans Med Imaging | 2023 | https://conductscience.org/library/papers/36121938 | PubMed |
| 35816534 | Variational Manifold Learning From Incomplete Data: Application to Multislice Dynamic MRI. | IEEE Trans Med Imaging | 2022 | https://conductscience.org/library/papers/35816534 | PubMed |
| 35714617 | Dynamic imaging using motion-compensated smoothness regularization on manifolds (MoCo-SToRM). | Phys Med Biol | 2022 | https://conductscience.org/library/papers/35714617 | PubMed |
| 35436187 | Dynamic Imaging Using Deep Bi-Linear Unsupervised Representation (DEBLUR). | IEEE Trans Med Imaging | 2022 | https://conductscience.org/library/papers/35436187 | PubMed |
| 35426473 | Optimization of through-time radial GRAPPA with coil compression and weight sharing. | Magn Reson Med | 2022 | https://conductscience.org/library/papers/35426473 | PubMed |
| 34336134 | DEEP GENERATIVE STORM MODEL FOR DYNAMIC IMAGING. | Proc IEEE Int Symp Biomed Imaging | 2021 | https://conductscience.org/library/papers/34336134 | PubMed |
| 33720831 | Dynamic Imaging Using a Deep Generative SToRM (Gen-SToRM) Model. | IEEE Trans Med Imaging | 2021 | https://conductscience.org/library/papers/33720831 | PubMed |
Data dates
The date of each source this release read.
- Trials
- 2026-11-12
- Gene search
- 2026-11-11
- Pipelines
- 2026-09-18
None in this release
- Trials
- Comments and corrections
- Genes
- Drugs
- Data
Sources 11
- ChEMBL, through Open TargetsCC BY-SA 3.0
- ClinicalTrials.govNo license stated
- HGNCCC0
- iCiteCC BY 4.0
- NCBI GenePublic domain (US government)
- NIH RePORTER's grant and paper linksPublic domain
- Open TargetsCC0 1.0
- PMC's ID filePublic domain (US government)
- PubMedNLM's terms
- PubTator 3Public domain
- UniProtCC BY 4.0
Each source's terms
- ChEMBL, through Open TargetsCC BY-SA 3.0, for the parts from ChEMBL. Read on 8 Nov 2026 at https://platform-docs.opentargets.org/licence
- ClinicalTrials.govnone stated
- HGNCCC0: https://www.genenames.org/about/license/
- iCiteCC BY 4.0
- NCBI GeneNone named for the file. NCBI says information created by or for the US government on its site is in the public domain, and asks that NLM be acknowledged: https://www.ncbi.nlm.nih.gov/home/about/policies/
- NIH RePORTER's grant and paper linksPublic domain (NIH RePORTER)
- Open TargetsCC0 1.0. Open Targets asks that users cite its latest paper: Buniello et al. 2025, Open Targets Platform: facilitating therapeutic hypotheses building in drug discovery, Nucleic Acids Research 53(D1):D1467, PMID 39657122. Read on 8 Nov 2026 at https://platform-docs.opentargets.org/licence
- PMC's ID fileNone named for the file. NCBI says information created by or for the US government on its site is in the public domain, and asks that NLM be acknowledged: https://www.ncbi.nlm.nih.gov/home/about/policies/
- PubMedNLM's terms
- PubTator 3Public domain
- UniProtCC BY 4.0. UniProt's licence file: "All databases and documents in the UniProt FTP directory may be copied and redistributed freely, without advance permission, provided that this copyright statement is reproduced with each copy." UniProt asks that users cite its latest paper: The UniProt Consortium, UniProt: the Universal Protein Knowledgebase in 2025, Nucleic Acids Research 53:D609-D617, https://doi.org/10.1093/nar/gkae1010. Read on 9 Nov 2026 at https://www.uniprot.org/help/license
ClinicalTrials.gov's data carry an international copyright outside the United States: https://clinicaltrials.gov/about-site/terms-conditions.
For software
Read this paper from software.
The record and each of its lists are JSON, twenty rows a page. No key needed for records and first pages, up to 100 calls a day. With a free key, your account gets 2,000 a day and every page.
GET https://conductscience.org/api/papers/v1/32746136
GET https://conductscience.org/api/papers/v1/32746136/references?page=2