ConductScience.org, home

Paper33530587

Electrical Properties Tomography: A Methodological Review.

Leijsen R and 4 others. Diagnostics (Basel), 2021. Cited by 31 papers, by iCite.

Cite this record

ConductScience Library. Electrical Properties Tomography: A Methodological Review. Papers, record 33530587. Release papers-2026-11-12-0.1.0, 12 Nov 2026. https://conductscience.org/library/papers/33530587

Download JSON
Sources
11 sources
Release
papers-2026-11-12-0.1.0

Paper

PubMed's record of the paper, with iCite's citation figures. No abstract is shown.

Title
Electrical Properties Tomography: A Methodological Review.
PubMed
Journal
Diagnostics (Basel)
PubMed
Year
2021
PubMed
Publication types
Journal Article, Review
PubMed
Citations, by iCite
31
iCite
Relative citation ratio, by iCite
3.35
iCite
Revised in PubMed
2023-11-10
PubMed

Authors5

The authors in the order PubMed's record lists them, with the ORCID iDs it states.

Source PubMed

Download CSV of authors

Topics0

NLM's MeSH indexing of the paper, its major topics first.

None in this release.

Grants1

Each grant PubMed's record writes, matched to the NIH project NIH's grant and paper links name for this paper, and each of those links the record does not write.

Grant, as the record writes itAgencyCountryNIH projectStated by
670629European Research CouncilInternationalPubMed

Source PubMed

Download CSV of grants

References71

The papers the reference list in PubMed's record names, those in our copy of PubMed, in the list's order.

OrderPMIDTitleJournalYearIn PapersSource
11479201Dielectric properties of human glioma and surrounding tissue.Int J Hyperthermia1992https://conductscience.org/library/papers/1479201PubMed
230403619Reference-Based Integral MR-EPT:Simulation and Experiment Studies on the 9.4T MRI.IEEE Trans Biomed Eng2018https://conductscience.org/library/papers/30403619PubMed
323508259From complex B(1) mapping to local SAR estimation for human brain MR imaging using multi-channel transceiver coil at 7T.IEEE Trans Med Imaging2013https://conductscience.org/library/papers/23508259PubMed
433289858Brain Tissue Conductivity Measurements with MR-Electrical Properties Tomography: An In Vivo Study.Brain Topogr2021https://conductscience.org/library/papers/33289858PubMed
518799834Magnetic resonance electrical impedance tomography (MREIT) for high-resolution conductivity imaging.Physiol Meas2008https://conductscience.org/library/papers/18799834PubMed
625312919Tissue electrical property mapping from zero echo-time magnetic resonance imaging.IEEE Trans Med Imaging2015https://conductscience.org/library/papers/25312919PubMed
722692921Complex B1 mapping and electrical properties imaging of the human brain using a 16-channel transceiver coil at 7T.Magn Reson Med2013https://conductscience.org/library/papers/22692921PubMed
829870362Learned Primal-Dual Reconstruction.IEEE Trans Med Imaging2018https://conductscience.org/library/papers/29870362PubMed
929894829Quantitative susceptibility mapping using deep neural network: QSMnet.Neuroimage2018https://conductscience.org/library/papers/29894829PubMed
1028186884CSI-EPT in Presence of RF-Shield for MR-Coils.IEEE Trans Med Imaging2017https://conductscience.org/library/papers/28186884PubMed
1127108291B1-based SAR reconstruction using contrast source inversion-electric properties tomography (CSI-EPT).Med Biol Eng Comput2017https://conductscience.org/library/papers/27108291PubMed
1222374804B1-based specific energy absorption rate determination for nonquadrature radiofrequency excitation.Magn Reson Med2012https://conductscience.org/library/papers/22374804PubMed
1329115689Learning a variational network for reconstruction of accelerated MRI data.Magn Reson Med2018https://conductscience.org/library/papers/29115689PubMed
1416237248Magnetoacoustic tomography with magnetic induction (MAT-MI).Phys Med Biol2005https://conductscience.org/library/papers/16237248PubMed
1532365014Magnetic-Resonance-Based Electrical Property Mapping Using Global Maxwell Tomography With an 8-Channel Head Coil at 7 Tesla: A Simulation Study.IEEE Trans Biomed Eng2021https://conductscience.org/library/papers/32365014PubMed
1632783236MR electrical properties imaging using a generalized image-based method.Magn Reson Med2021https://conductscience.org/library/papers/32783236PubMed
1729774597Assessment of the generalization of learned image reconstruction and the potential for transfer learning.Magn Reson Med2019https://conductscience.org/library/papers/29774597PubMed
1834460473Developments in Electrical-Property Tomography Based on the Contrast-Source Inversion Method.J Imaging2019https://conductscience.org/library/papers/34460473PubMed
1925706578CSI-EPT: A Contrast Source Inversion Approach for Improved MRI-Based Electric Properties Tomography.IEEE Trans Med Imaging2015https://conductscience.org/library/papers/25706578PubMed
2023743673Determining electrical properties based on B(1) fields measured in an MR scanner using a multi-channel transmit/receive coil: a general approach.Phys Med Biol2013https://conductscience.org/library/papers/23743673PubMed

See all 71 referencesDownload CSV of references

Cited by19

The papers in our copy of PubMed whose reference list names this one, newest first. iCite, which reads more sources, counts 31 citations.

PMIDTitleJournalYearIn PapersSource
42448743Radiofrequency electrical conductivity reveals a distinct dimension of early human brain development.Sci Rep2026https://conductscience.org/library/papers/42448743PubMed
41795132Clinical Applications of Electrical Conductivity Imaging Using MRI.J Magn Reson Imaging2026https://conductscience.org/library/papers/41795132PubMed
41543109Standardization of MR Electrical Properties Tomography: A Guideline From the ISMRM Electro-Magnetic Tissue Properties Study Group.J Magn Reson Imaging2026https://conductscience.org/library/papers/41543109PubMed
41270373Roadmap towards personalized approaches and safety considerations in non-ionizing radiation: from dosimetry to therapeutic and diagnostic applications.Phys Med Biol2026https://conductscience.org/library/papers/41270373PubMed
41133303Ticept: Wideband Electrical Properties Tomography by Tissue Composition Assessment With Quantitative 1 $$ {}^1 $$ H 23 $$ {}^{23} $$ Na 39 $$ {}^{39} $$ K Multinuclear MRI.Magn Reson Med2026https://conductscience.org/library/papers/41133303PubMed
40831340MR Electrical Properties Tomography Acquisitions: A Guideline From the ISMRM Electro-Magnetic Tissue Properties Study Group.J Magn Reson Imaging2026https://conductscience.org/library/papers/40831340PubMed
40687759Electrical characteristics of the extracellular fluid in the body segments of Apis mellifera bees.PeerJ2025https://conductscience.org/library/papers/40687759PubMed
40411380Feasibility study of subject-specific, brain specific-absorption-rate maps retrieved from MRI data.Magn Reson Med2025https://conductscience.org/library/papers/40411380PubMed
40173341Electrical properties based B 1 + prediction for electrical properties tomography reconstruction evaluation.Magn Reson Med2025https://conductscience.org/library/papers/40173341PubMed
39105952Fast bias-corrected conductivity mapping using stimulated echoes.MAGMA2024https://conductscience.org/library/papers/39105952PubMed
39050972Unrolled Optimization via Physics-Assisted Convolutional Neural Network for MR-Based Electrical Properties Tomography: A Numerical Investigation.IEEE Open J Eng Med Biol2024https://conductscience.org/library/papers/39050972PubMed
38997324Changes of in vivo electrical conductivity in the brain and torso related to age, fat fraction and sex using MRI.Sci Rep2024https://conductscience.org/library/papers/38997324PubMed
37188769Use of machine learning to improve the estimation of conductivity and permittivity based on longitudinal relaxation time T1 in magnetic resonance at 7 T.Sci Rep2023https://conductscience.org/library/papers/37188769PubMed
36841894High frequency conductivity decomposition by solving physically constraint underdetermined inverse problem in human brain.Sci Rep2023https://conductscience.org/library/papers/36841894PubMed
36828386Repeatability and Reproducibility Uncertainty in Magnetic Resonance-Based Electric Properties Tomography of a Homogeneous Phantom.Tomography2023https://conductscience.org/library/papers/36828386PubMed
36104392Correlation analysis between the complex electrical permittivity and relaxation time of tissue mimicking phantoms in 7 T MRI.Sci Rep2022https://conductscience.org/library/papers/36104392PubMed
35381114Ultrafast B1 mapping with RF-prepared 3D FLASH acquisition: Correcting the bias due to T1 -induced k-space filtering effect.Magn Reson Med2022https://conductscience.org/library/papers/35381114PubMed
35111132Mini Review: Impedance Measurement in Neuroscience and Its Prospective Application in the Field of Surgical Neurooncology.Front Neurol2021https://conductscience.org/library/papers/35111132PubMed
34576970Comparison of Five Conductivity Tensor Models and Image Reconstruction Methods Using MRI.Molecules2021https://conductscience.org/library/papers/34576970PubMed

Download CSV of cited by

Data dates

The date of each source this release read.

PubMed
2026-11-06
PubMed
iCite
2026-11-05
iCite
PMC's ID file
2026-11-05
PMC's ID file
NIH RePORTER's grant and paper links
2026-11-01
NIH RePORTER's grant and paper links
Trials
2026-11-12
Gene search
2026-11-11
Pipelines
2026-09-18

None in this release

  • Trials
  • Comments and corrections
  • Genes
  • Drugs
  • Data

Sources 11

  • ChEMBL, through Open TargetsCC BY-SA 3.0
  • ClinicalTrials.govNo license stated
  • HGNCCC0
  • iCiteCC BY 4.0
  • NCBI GenePublic domain (US government)
  • NIH RePORTER's grant and paper linksPublic domain
  • Open TargetsCC0 1.0
  • PMC's ID filePublic domain (US government)
  • PubMedNLM's terms
  • PubTator 3Public domain
  • UniProtCC BY 4.0
Each source's terms
  • ChEMBL, through Open TargetsCC BY-SA 3.0, for the parts from ChEMBL. Read on 8 Nov 2026 at https://platform-docs.opentargets.org/licence
  • ClinicalTrials.govnone stated
  • HGNCCC0: https://www.genenames.org/about/license/
  • iCiteCC BY 4.0
  • NCBI GeneNone named for the file. NCBI says information created by or for the US government on its site is in the public domain, and asks that NLM be acknowledged: https://www.ncbi.nlm.nih.gov/home/about/policies/
  • NIH RePORTER's grant and paper linksPublic domain (NIH RePORTER)
  • Open TargetsCC0 1.0. Open Targets asks that users cite its latest paper: Buniello et al. 2025, Open Targets Platform: facilitating therapeutic hypotheses building in drug discovery, Nucleic Acids Research 53(D1):D1467, PMID 39657122. Read on 8 Nov 2026 at https://platform-docs.opentargets.org/licence
  • PMC's ID fileNone named for the file. NCBI says information created by or for the US government on its site is in the public domain, and asks that NLM be acknowledged: https://www.ncbi.nlm.nih.gov/home/about/policies/
  • PubMedNLM's terms
  • PubTator 3Public domain
  • UniProtCC BY 4.0. UniProt's licence file: "All databases and documents in the UniProt FTP directory may be copied and redistributed freely, without advance permission, provided that this copyright statement is reproduced with each copy." UniProt asks that users cite its latest paper: The UniProt Consortium, UniProt: the Universal Protein Knowledgebase in 2025, Nucleic Acids Research 53:D609-D617, https://doi.org/10.1093/nar/gkae1010. Read on 9 Nov 2026 at https://www.uniprot.org/help/license

ClinicalTrials.gov's data carry an international copyright outside the United States: https://clinicaltrials.gov/about-site/terms-conditions.

For software

Read this paper from software.

The record and each of its lists are JSON, twenty rows a page. No key.

GET https://conductscience.org/api/papers/v1/33530587

GET https://conductscience.org/api/papers/v1/33530587/references?page=2