Paper33744992
Low keV portal venous phase as a surrogate for pancreatic phase in a pancreatic protocol dual-energy CT: feasibility, image quality, and lesion conspicuity.
Noda Y and 5 others. Eur Radiol, 2021. Cited by 19 papers, by iCite.
Cite this record
ConductScience Library. Low keV portal venous phase as a surrogate for pancreatic phase in a pancreatic protocol dual-energy CT: feasibility, image quality, and lesion conspicuity. Papers, record 33744992. Release papers-2026-11-12-0.1.0, 12 Nov 2026. https://conductscience.org/library/papers/33744992
- Sources
- 11 sources
- Release
- papers-2026-11-12-0.1.0
Paper
PubMed's record of the paper, with iCite's citation figures. No abstract is shown.
- Title
- Low keV portal venous phase as a surrogate for pancreatic phase in a pancreatic protocol dual-energy CT: feasibility, image quality, and lesion conspicuity.
- PubMed
Topics12
NLM's MeSH indexing of the paper, its major topics first.
| MeSH term | Major |
|---|---|
| Carcinoma, Pancreatic Ductal | Major topic |
| Pancreatic Neoplasms | Major topic |
| Radiography, Dual-Energy Scanned Projection | Major topic |
| Aged | |
| Contrast Media | |
| Feasibility Studies | |
| Humans | |
| Pancreas | |
| Radiation Dosage | |
| Radiographic Image Interpretation, Computer-Assisted | |
| Signal-To-Noise Ratio | |
| Tomography, X-Ray Computed |
Source PubMed
References34
The papers the reference list in PubMed's record names, those in our copy of PubMed, in the list's order.
| Order | PMID | Title | Journal | Year | In Papers | Source |
|---|---|---|---|---|---|---|
| 1 | 28221093 | U.S. Diagnostic Reference Levels and Achievable Doses for 10 Adult CT Examinations. | Radiology | 2017 | https://conductscience.org/library/papers/28221093 | PubMed |
| 2 | 29063133 | Split-bolus pancreas CTA protocol for local staging of pancreatic cancer and detection and characterization of liver lesions. | Abdom Radiol (NY) | 2018 | https://conductscience.org/library/papers/29063133 | PubMed |
| 3 | 28533111 | Management of Incidental Pancreatic Cysts: A White Paper of the ACR Incidental Findings Committee. | J Am Coll Radiol | 2017 | https://conductscience.org/library/papers/28533111 | PubMed |
| 4 | 23674791 | Split-bolus spectral multidetector CT of the pancreas: assessment of radiation dose and tumor conspicuity. | Radiology | 2013 | https://conductscience.org/library/papers/23674791 | PubMed |
| 5 | 2053748 | 1990 Recommendations of the International Commission on Radiological Protection. | Ann ICRP | 1991 | https://conductscience.org/library/papers/2053748 | PubMed |
| 6 | 30506217 | Reducing both radiation and contrast doses in coronary CT angiography in lean patients on a 16-cm wide-detector CT using 70 kVp and ASiR-V algorithm, in comparison with the conventional 100-kVp protocol. | Eur Radiol | 2019 | https://conductscience.org/library/papers/30506217 | PubMed |
| 7 | 30325864 | A Prospective Study to Establish a New-Onset Diabetes Cohort: From the Consortium for the Study of Chronic Pancreatitis, Diabetes, and Pancreatic Cancer. | Pancreas | 2018 | https://conductscience.org/library/papers/30325864 | PubMed |
| 8 | 29787496 | Quantitative Comparison of Virtual Monochromatic Images of Dual Energy Computed Tomography Systems: Beam Hardening Artifact Correction and Variance in Computed Tomography Numbers: A Phantom Study. | J Comput Assist Tomogr | 2018 | https://conductscience.org/library/papers/29787496 | PubMed |
| 9 | 30332288 | Assessing Chemotherapeutic Response in Pancreatic Ductal Adenocarcinoma: Histogram Analysis of Iodine Concentration and CT Number in Single-Source Dual-Energy CT. | AJR Am J Roentgenol | 2018 | https://conductscience.org/library/papers/30332288 | PubMed |
| 10 | 31765976 | Iodine dose optimization in portal venous phase virtual monochromatic images of the abdomen: Prospective study on rapid kVp switching dual energy CT. | Eur J Radiol | 2020 | https://conductscience.org/library/papers/31765976 | PubMed |
| 11 | 31471753 | Low-dose CT angiography using ASiR-V for potential living renal donors: a prospective analysis of image quality and diagnostic accuracy. | Eur Radiol | 2020 | https://conductscience.org/library/papers/31471753 | PubMed |
| 12 | 30155698 | Lower energy levels and iodine-based material decomposition images increase pancreatic ductal adenocarcinoma conspicuity on rapid kV-switching dual-energy CT. | Abdom Radiol (NY) | 2019 | https://conductscience.org/library/papers/30155698 | PubMed |
| 13 | 8637990 | Two-phase helical CT for pancreatic tumors: pancreatic versus hepatic phase enhancement of tumor, pancreas, and vascular structures. | Radiology | 1996 | https://conductscience.org/library/papers/8637990 | PubMed |
| 14 | 31478800 | Determining Malignant Potential of Intraductal Papillary Mucinous Neoplasm of the Pancreas: CT versus MRI by Using Revised 2017 International Consensus Guidelines. | Radiology | 2019 | https://conductscience.org/library/papers/31478800 | PubMed |
| 15 | 31738200 | A Third-Generation Adaptive Statistical Iterative Reconstruction for Contrast-Enhanced 4-Dimensional Dual-Energy Computed Tomography for Pancreatic Cancer. | J Comput Assist Tomogr | 2021 | https://conductscience.org/library/papers/31738200 | PubMed |
| 16 | 28673448 | Renovascular CT: comparison between adaptive statistical iterative reconstruction and model-based iterative reconstruction. | Clin Radiol | 2017 | https://conductscience.org/library/papers/28673448 | PubMed |
| 17 | 24354378 | Pancreatic ductal adenocarcinoma radiology reporting template: consensus statement of the Society of Abdominal Radiology and the American Pancreatic Association. | Radiology | 2014 | https://conductscience.org/library/papers/24354378 | PubMed |
| 18 | 29857855 | Dual-layer spectral computed tomography: Virtual non-contrast in comparison to true non-contrast images. | Eur J Radiol | 2018 | https://conductscience.org/library/papers/29857855 | PubMed |
| 19 | 31837969 | New Fast kVp Switching Dual-Energy CT: Reduced Severity of Beam Hardening Artifacts and Improved Image Quality in Reduced-Iodine Virtual Monochromatic Imaging. | Acad Radiol | 2020 | https://conductscience.org/library/papers/31837969 | PubMed |
| 20 | 30209591 | Comparison of full-iodine conventional CT and half-iodine virtual monochromatic imaging: advantages and disadvantages. | Eur Radiol | 2019 | https://conductscience.org/library/papers/30209591 | PubMed |
Cited by15
The papers in our copy of PubMed whose reference list names this one, newest first. iCite, which reads more sources, counts 19 citations.
| PMID | Title | Journal | Year | In Papers | Source |
|---|---|---|---|---|---|
| 42877528 | Strategy for early diagnosis of pancreatic cancer. | Front Gastroenterol (Lausanne) | 2026 | https://conductscience.org/library/papers/42877528 | PubMed |
| 42782328 | Conspicuity and characterization of pre-selected hypodense hepatic lesions in pancreatic cancer patients: limited clinical value of dual-energy portal phase CT. | Abdom Radiol (NY) | 2026 | https://conductscience.org/library/papers/42782328 | PubMed |
| 42667564 | What you don't see matters: dual-energy CT in emergency radiology. | Jpn J Radiol | 2026 | https://conductscience.org/library/papers/42667564 | PubMed |
| 41204103 | Differentiation of non-hypervascular non-functional pancreatic neuroendocrine neoplasms from solid pseudopapillary neoplasms using dual-layer spectral detector CT. | BMC Med Imaging | 2025 | https://conductscience.org/library/papers/41204103 | PubMed |
| 41081176 | Dual-layer spectral detector computed tomography for improving the demonstration of the communication between intraductal papillary mucinous neoplasms and pancreatic duct. | Quant Imaging Med Surg | 2025 | https://conductscience.org/library/papers/41081176 | PubMed |
| 39453034 | Diagnostic Value of Contrast-Enhanced Dual-Energy Computed Tomography in the Pancreatic Parenchymal and Delayed Phases for Pancreatic Cancer. | Tomography | 2024 | https://conductscience.org/library/papers/39453034 | PubMed |
| 39318563 | Diagnostic Imaging Performance of Dual-Energy Computed Tomography Compared with Conventional Computed Tomography and Magnetic Resonance Imaging for Uterine Cervical Cancer. | Indian J Radiol Imaging | 2024 | https://conductscience.org/library/papers/39318563 | PubMed |
| 39139258 | Comparison of preoperative diagnostic performance between dual-energy CT, conventional CT, and MRI in endometrial cancer. | Pol J Radiol | 2024 | https://conductscience.org/library/papers/39139258 | PubMed |
| 39046499 | Multi-reader multiparametric DECT study evaluating different strengths of iterative and deep learning-based image reconstruction techniques. | Eur Radiol | 2025 | https://conductscience.org/library/papers/39046499 | PubMed |
| 38913243 | Evaluation of pancreatic iodine uptake and related influential factors in multiphase dual-energy CT. | Eur Radiol | 2024 | https://conductscience.org/library/papers/38913243 | PubMed |
| 38075408 | Evaluation of virtual monochromatic imaging with dual-energy computed tomography of small liver metastases from malignant abdominal tumours: Quantitative and qualitative analyses. | Acta Radiol Open | 2023 | https://conductscience.org/library/papers/38075408 | PubMed |
| 37581057 | Can spectral computed tomography (CT) replace perfusion CT to assess the histological classification of non-small cell lung cancer? | Quant Imaging Med Surg | 2023 | https://conductscience.org/library/papers/37581057 | PubMed |
| 37079029 | Current state of radiomic research in pancreatic cancer: focusing on study design and reproducibility of findings. | Eur Radiol | 2023 | https://conductscience.org/library/papers/37079029 | PubMed |
| 36412684 | DECT Numbers in Upper Abdominal Organs for Differential Diagnosis: A Feasibility Study. | Tomography | 2022 | https://conductscience.org/library/papers/36412684 | PubMed |
| 35238970 | Deep learning image reconstruction for improving image quality of contrast-enhanced dual-energy CT in abdomen. | Eur Radiol | 2022 | https://conductscience.org/library/papers/35238970 | PubMed |
Data dates
The date of each source this release read.
- Trials
- 2026-11-12
- Gene search
- 2026-11-11
- Pipelines
- 2026-09-18
None in this release
- Grants
- Trials
- Comments and corrections
- Genes
- Drugs
- Data
Sources 11
- ChEMBL, through Open TargetsCC BY-SA 3.0
- ClinicalTrials.govNo license stated
- HGNCCC0
- iCiteCC BY 4.0
- NCBI GenePublic domain (US government)
- NIH RePORTER's grant and paper linksPublic domain
- Open TargetsCC0 1.0
- PMC's ID filePublic domain (US government)
- PubMedNLM's terms
- PubTator 3Public domain
- UniProtCC BY 4.0
Each source's terms
- ChEMBL, through Open TargetsCC BY-SA 3.0, for the parts from ChEMBL. Read on 8 Nov 2026 at https://platform-docs.opentargets.org/licence
- ClinicalTrials.govnone stated
- HGNCCC0: https://www.genenames.org/about/license/
- iCiteCC BY 4.0
- NCBI GeneNone named for the file. NCBI says information created by or for the US government on its site is in the public domain, and asks that NLM be acknowledged: https://www.ncbi.nlm.nih.gov/home/about/policies/
- NIH RePORTER's grant and paper linksPublic domain (NIH RePORTER)
- Open TargetsCC0 1.0. Open Targets asks that users cite its latest paper: Buniello et al. 2025, Open Targets Platform: facilitating therapeutic hypotheses building in drug discovery, Nucleic Acids Research 53(D1):D1467, PMID 39657122. Read on 8 Nov 2026 at https://platform-docs.opentargets.org/licence
- PMC's ID fileNone named for the file. NCBI says information created by or for the US government on its site is in the public domain, and asks that NLM be acknowledged: https://www.ncbi.nlm.nih.gov/home/about/policies/
- PubMedNLM's terms
- PubTator 3Public domain
- UniProtCC BY 4.0. UniProt's licence file: "All databases and documents in the UniProt FTP directory may be copied and redistributed freely, without advance permission, provided that this copyright statement is reproduced with each copy." UniProt asks that users cite its latest paper: The UniProt Consortium, UniProt: the Universal Protein Knowledgebase in 2025, Nucleic Acids Research 53:D609-D617, https://doi.org/10.1093/nar/gkae1010. Read on 9 Nov 2026 at https://www.uniprot.org/help/license
ClinicalTrials.gov's data carry an international copyright outside the United States: https://clinicaltrials.gov/about-site/terms-conditions.
For software
Read this paper from software.
The record and each of its lists are JSON, twenty rows a page. No key needed for records and first pages, up to 100 calls a day. With a free key, your account gets 2,000 a day and every page.
GET https://conductscience.org/api/papers/v1/33744992
GET https://conductscience.org/api/papers/v1/33744992/references?page=2