Paper35831718
Improved visualization of the wrist at lower radiation dose with photon-counting-detector CT.
Rajendran K and 8 others. Skeletal Radiol, 2023. Cited by 57 papers, by iCite.
Cite this record
ConductScience Library. Improved visualization of the wrist at lower radiation dose with photon-counting-detector CT. Papers, record 35831718. Release papers-2026-11-12-0.1.0, 12 Nov 2026. https://conductscience.org/library/papers/35831718
- Sources
- 11 sources
- Release
- papers-2026-11-12-0.1.0
Paper
PubMed's record of the paper, with iCite's citation figures. No abstract is shown.
- Title
- Improved visualization of the wrist at lower radiation dose with photon-counting-detector CT.
- PubMed
Topics8
NLM's MeSH indexing of the paper, its major topics first.
| MeSH term | Major |
|---|---|
| Wrist | Major topic |
| Photons | Major topic |
| Male | |
| Female | |
| Humans | |
| Phantoms, Imaging | |
| Tomography, X-Ray Computed | |
| Radiation Dosage |
Source PubMed
References23
The papers the reference list in PubMed's record names, those in our copy of PubMed, in the list's order.
| Order | PMID | Title | Journal | Year | In Papers | Source |
|---|---|---|---|---|---|---|
| 1 | 31985604 | Quantitative Knee Arthrography in a Large Animal Model of Osteoarthritis Using Photon-Counting Detector CT. | Invest Radiol | 2020 | https://conductscience.org/library/papers/31985604 | PubMed |
| 2 | 33610503 | Feasibility of lung imaging with a large field-of-view spectral photon-counting CT system. | Diagn Interv Imaging | 2021 | https://conductscience.org/library/papers/33610503 | PubMed |
| 3 | 33657475 | Computed tomography with a full FOV photon-counting detector in a clinical setting, the first experience. | Eur J Radiol | 2021 | https://conductscience.org/library/papers/33657475 | PubMed |
| 4 | 34352805 | High-Pitch Photon-Counting Detector Computed Tomography Angiography of the Aorta: Intraindividual Comparison to Energy-Integrating Detector Computed Tomography at Equal Radiation Dose. | Invest Radiol | 2022 | https://conductscience.org/library/papers/34352805 | PubMed |
| 5 | 28042589 | Dose-efficient ultrahigh-resolution scan mode using a photon counting detector computed tomography system. | J Med Imaging (Bellingham) | 2016 | https://conductscience.org/library/papers/28042589 | PubMed |
| 6 | 31770297 | Dose Reduction for Sinus and Temporal Bone Imaging Using Photon-Counting Detector CT With an Additional Tin Filter. | Invest Radiol | 2020 | https://conductscience.org/library/papers/31770297 | PubMed |
| 7 | 24089889 | Vision 20/20: Single photon counting x-ray detectors in medical imaging. | Med Phys | 2013 | https://conductscience.org/library/papers/24089889 | PubMed |
| 8 | 19673201 | Optimal "image-based" weighting for energy-resolved CT. | Med Phys | 2009 | https://conductscience.org/library/papers/19673201 | PubMed |
| 9 | 33113525 | Photon-counting x-ray detectors for CT. | Phys Med Biol | 2021 | https://conductscience.org/library/papers/33113525 | PubMed |
| 10 | 34271558 | Full field-of-view, high-resolution, photon-counting detector CT: technical assessment and initial patient experience. | Phys Med Biol | 2021 | https://conductscience.org/library/papers/34271558 | PubMed |
| 11 | 30179101 | Photon-counting CT: Technical Principles and Clinical Prospects. | Radiology | 2018 | https://conductscience.org/library/papers/30179101 | PubMed |
| 12 | 34603984 | Ultra-high resolution computed tomography of joints: practical recommendations for acquisition protocol optimization. | Quant Imaging Med Surg | 2021 | https://conductscience.org/library/papers/34603984 | PubMed |
| 13 | 33249223 | Photon-counting CT review. | Phys Med | 2020 | https://conductscience.org/library/papers/33249223 | PubMed |
| 14 | 17555253 | Novel ultrahigh resolution data acquisition and image reconstruction for multi-detector row CT. | Med Phys | 2007 | https://conductscience.org/library/papers/17555253 | PubMed |
| 15 | 33398008 | Potential of ultra-high-resolution photon-counting CT of bone metastases: initial experiences in breast cancer patients. | NPJ Breast Cancer | 2021 | https://conductscience.org/library/papers/33398008 | PubMed |
| 16 | 32040726 | Physical evaluation of an ultra-high-resolution CT scanner. | Eur Radiol | 2020 | https://conductscience.org/library/papers/32040726 | PubMed |
| 17 | 26818529 | Human Imaging With Photon Counting-Based Computed Tomography at Clinical Dose Levels: Contrast-to-Noise Ratio and Cadaver Studies. | Invest Radiol | 2016 | https://conductscience.org/library/papers/26818529 | PubMed |
| 18 | 33608927 | Location and direction dependence in the 3D MTF for a high-resolution CT system. | Med Phys | 2021 | https://conductscience.org/library/papers/33608927 | PubMed |
| 19 | 26840654 | Abdominal Imaging with Contrast-enhanced Photon-counting CT: First Human Experience. | Radiology | 2016 | https://conductscience.org/library/papers/26840654 | PubMed |
| 20 | 34904876 | First Clinical Photon-counting Detector CT System: Technical Evaluation. | Radiology | 2022 | https://conductscience.org/library/papers/34904876 | PubMed |
Cited by35
The papers in our copy of PubMed whose reference list names this one, newest first. iCite, which reads more sources, counts 57 citations.
| PMID | Title | Journal | Year | In Papers | Source |
|---|---|---|---|---|---|
| 42517926 | Precision of photon-counting detector CT compared to conventional CT for total wrist arthroplasty migration: a cadaveric and clinical study. | Skeletal Radiol | 2026 | https://conductscience.org/library/papers/42517926 | PubMed |
| 42399950 | Kinematic tracking of the small bones of the wrist in sequential 3DCT and dynamic 4DCT volume images using open-source Hierarchical 3D Registration, a module within SlicerAutoscoperM. | Biomed Eng Online | 2026 | https://conductscience.org/library/papers/42399950 | PubMed |
| 42063470 | Pediatric pseudo-tumor of the ischio-pubic ramus in virtual non-calcium photon-counting scanner: A case report. | Radiol Case Rep | 2026 | https://conductscience.org/library/papers/42063470 | PubMed |
| 41726309 | Photon-Counting CT in Musculoskeletal Radiology: Technical Principles, Clinical Applications, and Future Directions. | J Belg Soc Radiol | 2026 | https://conductscience.org/library/papers/41726309 | PubMed |
| 41324689 | Dual-energy CT for detection of knee fractures as alternative to MRI. | Skeletal Radiol | 2026 | https://conductscience.org/library/papers/41324689 | PubMed |
| 41185647 | The role of musculoskeletal radiologists in emergency and trauma settings: current and emerging imaging modalities. | BJR Open | 2025 | https://conductscience.org/library/papers/41185647 | PubMed |
| 40883645 | Photon-counting CT versus energy-integrating detector and flat-panel CT for cadaveric wrist arthrography with additional tin filter dose reduction. | Eur Radiol Exp | 2025 | https://conductscience.org/library/papers/40883645 | PubMed |
| 40449254 | Four-dimensional computed tomography-derived distal radioulnar joint osteokinematics during pronosupination with unilateral triangular fibrocartilage complex injuries. | J Biomech | 2025 | https://conductscience.org/library/papers/40449254 | PubMed |
| 40433271 | Updates in pediatric upper extremity imaging. | J Pediatr Soc North Am | 2024 | https://conductscience.org/library/papers/40433271 | PubMed |
| 40310571 | Assessment of metal artifacts from titanium wrist prostheses: photon-counting versus energy-integrating detector CT. | Eur Radiol Exp | 2025 | https://conductscience.org/library/papers/40310571 | PubMed |
| 39907791 | Sex differences in photon-counting detector computed tomography-derived scaphotrapeziotrapezoid joint morphometrics. | Skeletal Radiol | 2025 | https://conductscience.org/library/papers/39907791 | PubMed |
| 39870692 | Dual-energy CT-derived virtual noncalcium imaging to assess bone marrow lesions in patients with knee osteoarthritis. | Sci Rep | 2025 | https://conductscience.org/library/papers/39870692 | PubMed |
| 39088264 | Photon-Counting Detector CT Applications in Musculoskeletal Radiology. | Invest Radiol | 2025 | https://conductscience.org/library/papers/39088264 | PubMed |
| 38956833 | Morphology of the scaphotrapeziotrapezoid joint: A multi-domain statistical shape modeling approach. | J Orthop Res | 2024 | https://conductscience.org/library/papers/38956833 | PubMed |
| 38942460 | Photon-Counting Computed Tomography: Experience in Musculoskeletal Imaging. | Korean J Radiol | 2024 | https://conductscience.org/library/papers/38942460 | PubMed |
| 38833188 | Photon-Counting Computed Tomography for Microstructural Imaging of Bone and Joints. | Curr Osteoporos Rep | 2024 | https://conductscience.org/library/papers/38833188 | PubMed |
| 38789217 | Detection of scapholunate interosseous ligament injury using dynamic computed tomography-derived arthrokinematics: A prospective clinical trial. | Med Eng Phys | 2024 | https://conductscience.org/library/papers/38789217 | PubMed |
| 38786317 | Cranial Computer Tomography with Photon Counting and Energy-Integrated Detectors: Objective Comparison in the Same Patients. | Diagnostics (Basel) | 2024 | https://conductscience.org/library/papers/38786317 | PubMed |
| 38441616 | Chances and challenges of photon-counting CT in musculoskeletal imaging. | Skeletal Radiol | 2024 | https://conductscience.org/library/papers/38441616 | PubMed |
| 38396389 | Comparison of Bone Evaluation and Metal Artifact between Photon-Counting CT and Five Energy-Integrating-Detector CT under Standardized Conditions Using Cadaveric Forearms. | Diagnostics (Basel) | 2024 | https://conductscience.org/library/papers/38396389 | PubMed |
Data dates
The date of each source this release read.
- Trials
- 2026-11-12
- Gene search
- 2026-11-11
- Pipelines
- 2026-09-18
None in this release
- Grants
- Trials
- Comments and corrections
- Genes
- Drugs
- Data
Sources 11
- ChEMBL, through Open TargetsCC BY-SA 3.0
- ClinicalTrials.govNo license stated
- HGNCCC0
- iCiteCC BY 4.0
- NCBI GenePublic domain (US government)
- NIH RePORTER's grant and paper linksPublic domain
- Open TargetsCC0 1.0
- PMC's ID filePublic domain (US government)
- PubMedNLM's terms
- PubTator 3Public domain
- UniProtCC BY 4.0
Each source's terms
- ChEMBL, through Open TargetsCC BY-SA 3.0, for the parts from ChEMBL. Read on 8 Nov 2026 at https://platform-docs.opentargets.org/licence
- ClinicalTrials.govnone stated
- HGNCCC0: https://www.genenames.org/about/license/
- iCiteCC BY 4.0
- NCBI GeneNone named for the file. NCBI says information created by or for the US government on its site is in the public domain, and asks that NLM be acknowledged: https://www.ncbi.nlm.nih.gov/home/about/policies/
- NIH RePORTER's grant and paper linksPublic domain (NIH RePORTER)
- Open TargetsCC0 1.0. Open Targets asks that users cite its latest paper: Buniello et al. 2025, Open Targets Platform: facilitating therapeutic hypotheses building in drug discovery, Nucleic Acids Research 53(D1):D1467, PMID 39657122. Read on 8 Nov 2026 at https://platform-docs.opentargets.org/licence
- PMC's ID fileNone named for the file. NCBI says information created by or for the US government on its site is in the public domain, and asks that NLM be acknowledged: https://www.ncbi.nlm.nih.gov/home/about/policies/
- PubMedNLM's terms
- PubTator 3Public domain
- UniProtCC BY 4.0. UniProt's licence file: "All databases and documents in the UniProt FTP directory may be copied and redistributed freely, without advance permission, provided that this copyright statement is reproduced with each copy." UniProt asks that users cite its latest paper: The UniProt Consortium, UniProt: the Universal Protein Knowledgebase in 2025, Nucleic Acids Research 53:D609-D617, https://doi.org/10.1093/nar/gkae1010. Read on 9 Nov 2026 at https://www.uniprot.org/help/license
ClinicalTrials.gov's data carry an international copyright outside the United States: https://clinicaltrials.gov/about-site/terms-conditions.
For software
Read this paper from software.
The record and each of its lists are JSON, twenty rows a page. No key needed for records and first pages, up to 100 calls a day. With a free key, your account gets 2,000 a day and every page.
GET https://conductscience.org/api/papers/v1/35831718
GET https://conductscience.org/api/papers/v1/35831718/references?page=2