Paper35945239
A lightweight magnetically shielded room with active shielding.
Holmes N and 25 others. Sci Rep, 2022. Cited by 36 papers, by iCite.
Cite this record
ConductScience Library. A lightweight magnetically shielded room with active shielding. Papers, record 35945239. Release papers-2026-11-12-0.1.0, 12 Nov 2026. https://conductscience.org/library/papers/35945239
- Sources
- 11 sources
- Release
- papers-2026-11-12-0.1.0
Paper
PubMed's record of the paper, with iCite's citation figures. No abstract is shown.
Topics7
NLM's MeSH indexing of the paper, its major topics first.
| MeSH term | Major |
|---|---|
| Functional Neuroimaging | Major topic |
| Magnetoencephalography | Major topic |
| Brain | |
| Humans | |
| Magnetic Fields | |
| Magnetic Resonance Imaging | |
| Magnetic Resonance Spectroscopy |
Source PubMed
Grants3
Each grant PubMed's record writes, matched to the NIH project NIH's grant and paper links name for this paper, and each of those links the record does not write.
| Grant, as the record writes it | Agency | Country | NIH project | Stated by | Source |
|---|---|---|---|---|---|
| 203257/Z/16/Z | Wellcome Trust | United Kingdom | PubMed | PubMed | |
| R44 MH110288 | NIMH NIH HHS | United States | R44MH110288 | PubMed | NIH RePORTER |
| 203257/B/16/Z | Wellcome Trust | United Kingdom | PubMed | PubMed |
References19
The papers the reference list in PubMed's record names, those in our copy of PubMed, in the list's order.
| Order | PMID | Title | Journal | Year | In Papers | Source |
|---|---|---|---|---|---|---|
| 1 | 31647893 | Magnetoencephalography in Cognitive Neuroscience: A Primer. | Neuron | 2019 | https://conductscience.org/library/papers/31647893 | PubMed |
| 2 | 24095841 | Multi-coil magnetic field modeling. | J Magn Reson | 2013 | https://conductscience.org/library/papers/24095841 | PubMed |
| 3 | 31578383 | Balanced, bi-planar magnetic field and field gradient coils for field compensation in wearable magnetoencephalography. | Sci Rep | 2019 | https://conductscience.org/library/papers/31578383 | PubMed |
| 4 | 31726253 | Evaluating motor cortical oscillations and age-related change in autism spectrum disorder. | Neuroimage | 2020 | https://conductscience.org/library/papers/31726253 | PubMed |
| 5 | 32480036 | Multi-channel whole-head OPM-MEG: Helmet design and a comparison with a conventional system. | Neuroimage | 2020 | https://conductscience.org/library/papers/32480036 | PubMed |
| 6 | 25085172 | A magnetically shielded room with ultra low residual field and gradient. | Rev Sci Instrum | 2014 | https://conductscience.org/library/papers/25085172 | PubMed |
| 7 | 31978102 | Non-Invasive Functional-Brain-Imaging with an OPM-based Magnetoencephalography System. | PLoS One | 2020 | https://conductscience.org/library/papers/31978102 | PubMed |
| 8 | 34324421 | Magnetic Field Mapping and Correction for Moving OP-MEG. | IEEE Trans Biomed Eng | 2022 | https://conductscience.org/library/papers/34324421 | PubMed |
| 9 | 30885786 | On-scalp MEG system utilizing an actively shielded array of optically-pumped magnetometers. | Neuroimage | 2019 | https://conductscience.org/library/papers/30885786 | PubMed |
| 10 | 34273527 | Precision magnetic field modelling and control for wearable magnetoencephalography. | Neuroimage | 2021 | https://conductscience.org/library/papers/34273527 | PubMed |
| 11 | 12225013 | High-sensitivity atomic magnetometer unaffected by spin-exchange relaxation. | Phys Rev Lett | 2002 | https://conductscience.org/library/papers/12225013 | PubMed |
| 12 | 31702217 | New Limit on the Permanent Electric Dipole Moment of ^{129}Xe Using ^{3}He Comagnetometry and SQUID Detection. | Phys Rev Lett | 2019 | https://conductscience.org/library/papers/31702217 | PubMed |
| 13 | 5663803 | Magnetoencephalography: evidence of magnetic fields produced by alpha-rhythm currents. | Science | 1968 | https://conductscience.org/library/papers/5663803 | PubMed |
| 14 | 24200837 | A compact, high performance atomic magnetometer for biomedical applications. | Phys Med Biol | 2013 | https://conductscience.org/library/papers/24200837 | PubMed |
| 15 | 34811388 | Magnetic field compensation coil design for magnetoencephalography. | Sci Rep | 2021 | https://conductscience.org/library/papers/34811388 | PubMed |
| 16 | 25462795 | Dynamic multi-coil technique (DYNAMITE) shimming for echo-planar imaging of the human brain at 7 Tesla. | Neuroimage | 2015 | https://conductscience.org/library/papers/25462795 | PubMed |
| 17 | 30031934 | A bi-planar coil system for nulling background magnetic fields in scalp mounted magnetoencephalography. | Neuroimage | 2018 | https://conductscience.org/library/papers/30031934 | PubMed |
| 18 | 29562238 | Moving magnetoencephalography towards real-world applications with a wearable system. | Nature | 2018 | https://conductscience.org/library/papers/29562238 | PubMed |
| 19 | 28230841 | Magnetoencephalography for brain electrophysiology and imaging. | Nat Neurosci | 2017 | https://conductscience.org/library/papers/28230841 | PubMed |
Cited by28
The papers in our copy of PubMed whose reference list names this one, newest first. iCite, which reads more sources, counts 36 citations.
| PMID | Title | Journal | Year | In Papers | Source |
|---|---|---|---|---|---|
| 42740110 | Opportunities for Quantum Sensing in Epilepsy Diagnostics. | Sensors (Basel) | 2026 | https://conductscience.org/library/papers/42740110 | PubMed |
| 42197937 | Neuromagnetism "On the Cheap": Evaluating a Combined Cylindrical Shield and Partial-Coverage OPM-MEG System for Detecting Sensorimotor Responses in Humans. | Sensors (Basel) | 2026 | https://conductscience.org/library/papers/42197937 | PubMed |
| 42195624 | Multi-Layer Magnetic Shields Based on Fe-Based Nanocrystalline and Co-Based Amorphous Ribbons. | Materials (Basel) | 2026 | https://conductscience.org/library/papers/42195624 | PubMed |
| 41968540 | Revolutionizing Pediatric Neurophysiology With Magnetoencephalography. | Psychophysiology | 2026 | https://conductscience.org/library/papers/41968540 | PubMed |
| 40928747 | SPM-30 years and beyond. | Cereb Cortex | 2025 | https://conductscience.org/library/papers/40928747 | PubMed |
| 40800955 | Demonstrating equivalence across magnetoencephalography scanner platforms using neural fingerprinting. | Imaging Neurosci (Camb) | 2025 | https://conductscience.org/library/papers/40800955 | PubMed |
| 40800786 | Determining sensor geometry and gain in a wearable MEG system. | Imaging Neurosci (Camb) | 2025 | https://conductscience.org/library/papers/40800786 | PubMed |
| 40800346 | Simultaneous whole-head electrophysiological recordings using EEG and OPM-MEG. | Imaging Neurosci (Camb) | 2024 | https://conductscience.org/library/papers/40800346 | PubMed |
| 39860803 | Bias Calibration of Optically Pumped Magnetometers Based on Variable Sensitivity. | Sensors (Basel) | 2025 | https://conductscience.org/library/papers/39860803 | PubMed |
| 39859801 | Simulation Research on Low-Frequency Magnetic Noise in Fe-Based Nanocrystalline Magnetic Shields. | Materials (Basel) | 2025 | https://conductscience.org/library/papers/39859801 | PubMed |
| 39685313 | Fast Degaussing Procedure for a Magnetically Shielded Room. | Materials (Basel) | 2024 | https://conductscience.org/library/papers/39685313 | PubMed |
| 39597293 | Enhancement of Magnetic Shielding Based on Low-Noise Materials, Magnetization Control, and Active Compensation: A Review. | Materials (Basel) | 2024 | https://conductscience.org/library/papers/39597293 | PubMed |
| 39502465 | A novel, robust, and portable platform for magnetoencephalography using optically-pumped magnetometers. | Imaging Neurosci (Camb) | 2024 | https://conductscience.org/library/papers/39502465 | PubMed |
| 39302788 | Wearable Magnetoencephalography in a Lightly Shielded Environment. | IEEE Trans Biomed Eng | 2025 | https://conductscience.org/library/papers/39302788 | PubMed |
| 39181883 | Applications of OPM-MEG for translational neuroscience: a perspective. | Transl Psychiatry | 2024 | https://conductscience.org/library/papers/39181883 | PubMed |
| 38894294 | Noise Reduction and Localization Accuracy in a Mobile Magnetoencephalography System. | Sensors (Basel) | 2024 | https://conductscience.org/library/papers/38894294 | PubMed |
| 38558964 | A Novel, Robust, and Portable Platform for Magnetoencephalography using Optically Pumped Magnetometers. | bioRxiv | 2024 | https://conductscience.org/library/papers/38558964 | PubMed |
| 38463461 | Quantum enabled functional neuroimaging: the why and how of magnetoencephalography using optically pumped magnetometers. | Contemp Phys | 2022 | https://conductscience.org/library/papers/38463461 | PubMed |
| 38433646 | Adaptive multipole models of optically pumped magnetometer data. | Hum Brain Mapp | 2024 | https://conductscience.org/library/papers/38433646 | PubMed |
| 38089970 | Tri-axial rubidium and helium optically pumped magnetometers for on-scalp magnetoencephalography recording of interictal epileptiform discharges: a case study. | Front Neurosci | 2023 | https://conductscience.org/library/papers/38089970 | PubMed |
Data dates
The date of each source this release read.
- Trials
- 2026-11-12
- Gene search
- 2026-11-11
- Pipelines
- 2026-09-18
None in this release
- Trials
- Comments and corrections
- Genes
- Drugs
- Data
Sources 11
- ChEMBL, through Open TargetsCC BY-SA 3.0
- ClinicalTrials.govNo license stated
- HGNCCC0
- iCiteCC BY 4.0
- NCBI GenePublic domain (US government)
- NIH RePORTER's grant and paper linksPublic domain
- Open TargetsCC0 1.0
- PMC's ID filePublic domain (US government)
- PubMedNLM's terms
- PubTator 3Public domain
- UniProtCC BY 4.0
Each source's terms
- ChEMBL, through Open TargetsCC BY-SA 3.0, for the parts from ChEMBL. Read on 8 Nov 2026 at https://platform-docs.opentargets.org/licence
- ClinicalTrials.govnone stated
- HGNCCC0: https://www.genenames.org/about/license/
- iCiteCC BY 4.0
- NCBI GeneNone named for the file. NCBI says information created by or for the US government on its site is in the public domain, and asks that NLM be acknowledged: https://www.ncbi.nlm.nih.gov/home/about/policies/
- NIH RePORTER's grant and paper linksPublic domain (NIH RePORTER)
- Open TargetsCC0 1.0. Open Targets asks that users cite its latest paper: Buniello et al. 2025, Open Targets Platform: facilitating therapeutic hypotheses building in drug discovery, Nucleic Acids Research 53(D1):D1467, PMID 39657122. Read on 8 Nov 2026 at https://platform-docs.opentargets.org/licence
- PMC's ID fileNone named for the file. NCBI says information created by or for the US government on its site is in the public domain, and asks that NLM be acknowledged: https://www.ncbi.nlm.nih.gov/home/about/policies/
- PubMedNLM's terms
- PubTator 3Public domain
- UniProtCC BY 4.0. UniProt's licence file: "All databases and documents in the UniProt FTP directory may be copied and redistributed freely, without advance permission, provided that this copyright statement is reproduced with each copy." UniProt asks that users cite its latest paper: The UniProt Consortium, UniProt: the Universal Protein Knowledgebase in 2025, Nucleic Acids Research 53:D609-D617, https://doi.org/10.1093/nar/gkae1010. Read on 9 Nov 2026 at https://www.uniprot.org/help/license
ClinicalTrials.gov's data carry an international copyright outside the United States: https://clinicaltrials.gov/about-site/terms-conditions.
For software
Read this paper from software.
The record and each of its lists are JSON, twenty rows a page. No key.
GET https://conductscience.org/api/papers/v1/35945239
GET https://conductscience.org/api/papers/v1/35945239/authors?page=2