ConductScience.org, home

Paper36904637

Development and Evaluation of a Full-Waveform Resistance Training Monitoring System Based on a Linear Position Transducer.

Lu C and 6 others. Sensors (Basel), 2023. Cited by 2 papers, by iCite.

Cite this record

ConductScience Library. Development and Evaluation of a Full-Waveform Resistance Training Monitoring System Based on a Linear Position Transducer. Papers, record 36904637. Release papers-2026-11-12-0.1.0, 12 Nov 2026. https://conductscience.org/library/papers/36904637

Download JSON
Sources
11 sources
Release
papers-2026-11-12-0.1.0

Paper

PubMed's record of the paper, with iCite's citation figures. No abstract is shown.

Title
Development and Evaluation of a Full-Waveform Resistance Training Monitoring System Based on a Linear Position Transducer.
PubMed
Journal
Sensors (Basel)
PubMed
Year
2023
PubMed
Publication types
Journal Article
PubMed
Citations, by iCite
2
iCite
Relative citation ratio, by iCite
0.71
iCite
Revised in PubMed
2023-03-14
PubMed

Authors7

The authors in the order PubMed's record lists them, with the ORCID iDs it states.

OrderAuthorForenameKindORCID iD
1Lu CChangdahttps://orcid.org/0000-0003-0017-3975
2Zhang KKaiyuhttps://orcid.org/0000-0002-4187-341X
3Cui YYixionghttps://orcid.org/0000-0002-1755-9631
4Tian YYinsheng
5Wang SSiyao
6Cao JJie
7Shen YYanfei

Source PubMed

Download CSV of authors

Topics8

NLM's MeSH indexing of the paper, its major topics first.

MeSH termMajor
Resistance TrainingMajor topic
Humans
Posture
Software
Transducers
Monitoring, Physiologic
Arrhythmias, Cardiac
Muscle Strength

Source PubMed

Download CSV of topics

Grants2

Each grant PubMed's record writes, matched to the NIH project NIH's grant and paper links name for this paper, and each of those links the record does not write.

Grant, as the record writes itAgencyCountryNIH projectStated by
72071018National Natural Science Foundation of China under GrantPubMed
2018YFC2000600National Key R&D Program of China under GrantPubMed

Source PubMed

Download CSV of grants

References45

The papers the reference list in PubMed's record names, those in our copy of PubMed, in the list's order.

OrderPMIDTitleJournalYearIn PapersSource
124505103Eccentric exercise: mechanisms and effects when used as training regime or training adjunct.J Appl Physiol (1985)2014https://conductscience.org/library/papers/24505103PubMed
231094251The Effects of 10%, 20%, and 30% Velocity Loss Thresholds on Kinetic, Kinematic, and Repetition Characteristics During the Barbell Back Squat.Int J Sports Physiol Perform2020https://conductscience.org/library/papers/31094251PubMed
331471113Maximum velocity during loaded countermovement jumps obtained with an accelerometer, linear encoder and force platform: A comparison of technologies.J Biomech2019https://conductscience.org/library/papers/31471113PubMed
414620785Eccentric muscle contractions: their contribution to injury, prevention, rehabilitation, and sport.J Orthop Sports Phys Ther2003https://conductscience.org/library/papers/14620785PubMed
512744716Movement velocity in resistance training.Sports Med2003https://conductscience.org/library/papers/12744716PubMed
617194240The validation of a portable force plate for measuring force-time data during jumping and landing tasks.J Strength Cond Res2006https://conductscience.org/library/papers/17194240PubMed
728192832Velocity Loss as a Variable for Monitoring Resistance Exercise.Int J Sports Med2017https://conductscience.org/library/papers/28192832PubMed
829212552Validity and reliability of simple measurement device to assess the velocity of the barbell during squats.BMC Res Notes2017https://conductscience.org/library/papers/29212552PubMed
930426840Velocity- and power-load relationships in the half, parallel and full back squat.J Sports Sci2019https://conductscience.org/library/papers/30426840PubMed
1028253038Monitoring Training Loads: The Past, the Present, and the Future.Int J Sports Physiol Perform2017https://conductscience.org/library/papers/28253038PubMed
1134564328Validity and Effects of Placement of Velocity-Based Training Devices.Sports (Basel)2021https://conductscience.org/library/papers/34564328PubMed
1228182500Validity of Various Methods for Determining Velocity, Force, and Power in the Back Squat.Int J Sports Physiol Perform2017https://conductscience.org/library/papers/28182500PubMed
1332629842The Reliability and Validity of Current Technologies for Measuring Barbell Velocity in the Free-Weight Back Squat and Power Clean.Sports (Basel)2020https://conductscience.org/library/papers/32629842PubMed
1428704314Visual Feedback Attenuates Mean Concentric Barbell Velocity Loss and Improves Motivation, Competitiveness, and Perceived Workload in Male Adolescent Athletes.J Strength Cond Res2019https://conductscience.org/library/papers/28704314PubMed
1533105366Show Me, Tell Me, Encourage Me: The Effect of Different Forms of Feedback on Resistance Training Performance.J Strength Cond Res2020https://conductscience.org/library/papers/33105366PubMed
1615064596Fundamentals of resistance training: progression and exercise prescription.Med Sci Sports Exerc2004https://conductscience.org/library/papers/15064596PubMed
1729357481Repeated testing for the assessment of individual response to exercise training.J Appl Physiol (1985)2018https://conductscience.org/library/papers/29357481PubMed
1815320688Reliability and validity of a linear position transducer for measuring jump performance.J Strength Cond Res2004https://conductscience.org/library/papers/15320688PubMed
1930539090Estimation of Relative Load From Bar Velocity in the Full Back Squat Exercise.Sports Med Int Open2017https://conductscience.org/library/papers/30539090PubMed
2010753108How animals move: an integrative view.Science2000https://conductscience.org/library/papers/10753108PubMed

See all 45 referencesDownload CSV of references

Cited by2

The papers in our copy of PubMed whose reference list names this one, newest first. iCite, which reads more sources, counts 2 citations.

PMIDTitleJournalYearIn PapersSource
40920738A systematic review using a multi-layered criteria framework for assessing the validity and reliability of velocity monitoring devices in resistance training.PLoS One2025https://conductscience.org/library/papers/40920738PubMed
40407462Effects of Transducer Placement on Load-Velocity Relationships in Smith Machine and Free Weight Squats in Trained Women.J Funct Morphol Kinesiol2025https://conductscience.org/library/papers/40407462PubMed

Download CSV of cited by

Data dates

The date of each source this release read.

PubMed
2026-11-06
PubMed
iCite
2026-11-05
iCite
PMC's ID file
2026-11-05
PMC's ID file
NIH RePORTER's grant and paper links
2026-11-01
NIH RePORTER's grant and paper links
Trials
2026-11-12
Gene search
2026-11-11
Pipelines
2026-09-18

None in this release

  • Trials
  • Comments and corrections
  • Genes
  • Drugs
  • Data

Sources 11

  • ChEMBL, through Open TargetsCC BY-SA 3.0
  • ClinicalTrials.govNo license stated
  • HGNCCC0
  • iCiteCC BY 4.0
  • NCBI GenePublic domain (US government)
  • NIH RePORTER's grant and paper linksPublic domain
  • Open TargetsCC0 1.0
  • PMC's ID filePublic domain (US government)
  • PubMedNLM's terms
  • PubTator 3Public domain
  • UniProtCC BY 4.0
Each source's terms
  • ChEMBL, through Open TargetsCC BY-SA 3.0, for the parts from ChEMBL. Read on 8 Nov 2026 at https://platform-docs.opentargets.org/licence
  • ClinicalTrials.govnone stated
  • HGNCCC0: https://www.genenames.org/about/license/
  • iCiteCC BY 4.0
  • NCBI GeneNone named for the file. NCBI says information created by or for the US government on its site is in the public domain, and asks that NLM be acknowledged: https://www.ncbi.nlm.nih.gov/home/about/policies/
  • NIH RePORTER's grant and paper linksPublic domain (NIH RePORTER)
  • Open TargetsCC0 1.0. Open Targets asks that users cite its latest paper: Buniello et al. 2025, Open Targets Platform: facilitating therapeutic hypotheses building in drug discovery, Nucleic Acids Research 53(D1):D1467, PMID 39657122. Read on 8 Nov 2026 at https://platform-docs.opentargets.org/licence
  • PMC's ID fileNone named for the file. NCBI says information created by or for the US government on its site is in the public domain, and asks that NLM be acknowledged: https://www.ncbi.nlm.nih.gov/home/about/policies/
  • PubMedNLM's terms
  • PubTator 3Public domain
  • UniProtCC BY 4.0. UniProt's licence file: "All databases and documents in the UniProt FTP directory may be copied and redistributed freely, without advance permission, provided that this copyright statement is reproduced with each copy." UniProt asks that users cite its latest paper: The UniProt Consortium, UniProt: the Universal Protein Knowledgebase in 2025, Nucleic Acids Research 53:D609-D617, https://doi.org/10.1093/nar/gkae1010. Read on 9 Nov 2026 at https://www.uniprot.org/help/license

ClinicalTrials.gov's data carry an international copyright outside the United States: https://clinicaltrials.gov/about-site/terms-conditions.

For software

Read this paper from software.

The record and each of its lists are JSON, twenty rows a page. No key.

GET https://conductscience.org/api/papers/v1/36904637

GET https://conductscience.org/api/papers/v1/36904637/references?page=2