Paper39170202
Primary stability evaluation of different morse cone implants in low-density artificial bone blocks: A comparison between high-and low-speed drilling.
Romasco T and 5 others. Heliyon, 2024. Cited by 4 papers, by iCite.
Cite this record
ConductScience Library. Primary stability evaluation of different morse cone implants in low-density artificial bone blocks: A comparison between high-and low-speed drilling. Papers, record 39170202. Release papers-2026-11-12-0.1.0, 12 Nov 2026. https://conductscience.org/library/papers/39170202
- Sources
- 11 sources
- Release
- papers-2026-11-12-0.1.0
Paper
PubMed's record of the paper, with iCite's citation figures. No abstract is shown.
- Title
- Primary stability evaluation of different morse cone implants in low-density artificial bone blocks: A comparison between high-and low-speed drilling.
- PubMed
Topics0
NLM's MeSH indexing of the paper, its major topics first.
None in this release.
References62
The papers the reference list in PubMed's record names, those in our copy of PubMed, in the list's order.
| Order | PMID | Title | Journal | Year | In Papers | Source |
|---|---|---|---|---|---|---|
| 1 | 1879579 | Bone growth around dental implants. | Dent Clin North Am | 1991 | https://conductscience.org/library/papers/1879579 | PubMed |
| 2 | 38002077 | Crestal and Subcrestal Placement of Morse Cone Implant-Abutment Connection Implants: An In Vitro Finite Element Analysis (FEA) Study. | Biomedicines | 2023 | https://conductscience.org/library/papers/38002077 | PubMed |
| 3 | 30578579 | Comparison of heat generation between guided and conventional implant surgery for single and sequential drilling protocols-An in vitro study. | Clin Oral Implants Res | 2019 | https://conductscience.org/library/papers/30578579 | PubMed |
| 4 | 22633592 | Differences in implant stability associated with various methods of preparation of the implant bed: an in vitro study. | J Prosthet Dent | 2012 | https://conductscience.org/library/papers/22633592 | PubMed |
| 5 | 34885335 | Stability of Dental Implants and Thickness of Cortical Bone: Clinical Research and Future Perspectives. A Systematic Review. | Materials (Basel) | 2021 | https://conductscience.org/library/papers/34885335 | PubMed |
| 6 | 34127353 | The correlation of different methods for the assessment of bone quality in vivo: an observational study. | Int J Oral Maxillofac Surg | 2022 | https://conductscience.org/library/papers/34127353 | PubMed |
| 7 | 9151590 | Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis. | Clin Oral Implants Res | 1996 | https://conductscience.org/library/papers/9151590 | PubMed |
| 8 | 34826040 | Effect of low-speed drilling without irrigation on osseointegration: an experimental study in dogs. | Oral Maxillofac Surg | 2022 | https://conductscience.org/library/papers/34826040 | PubMed |
| 9 | 20070754 | Influence of surgical technique and surface roughness on the primary stability of an implant in artificial bone with different cortical thickness: a laboratory study. | Clin Oral Implants Res | 2010 | https://conductscience.org/library/papers/20070754 | PubMed |
| 10 | 12010160 | Thermal changes observed at implant sites during internal and external irrigation. | Clin Oral Implants Res | 2002 | https://conductscience.org/library/papers/12010160 | PubMed |
| 11 | 2597401 | Bone classification, training keys to implant success. | Dent Today | 1989 | https://conductscience.org/library/papers/2597401 | PubMed |
| 12 | 22106473 | Descriptive study of the longevity of dental implant surgery drills. | Clin Implant Dent Relat Res | 2011 | https://conductscience.org/library/papers/22106473 | PubMed |
| 13 | 30175131 | Effect of Different Morphology of Titanium Surface on the Bone Healing in Defects Filled Only with Blood Clot: A New Animal Study Design. | Biomed Res Int | 2018 | https://conductscience.org/library/papers/30175131 | PubMed |
| 14 | 29194944 | Relationship between implant stability measurements obtained by insertion torque and resonance frequency analysis: A systematic review. | Clin Implant Dent Relat Res | 2018 | https://conductscience.org/library/papers/29194944 | PubMed |
| 15 | 38147179 | The influence of truncated-conical implant length on primary stability in maxillary and mandibular regions: an in vitro study using polyurethane blocks. | Clin Oral Investig | 2023 | https://conductscience.org/library/papers/38147179 | PubMed |
| 16 | 24381734 | Role of primary stability for successful osseointegration of dental implants: Factors of influence and evaluation. | Interv Med Appl Sci | 2013 | https://conductscience.org/library/papers/24381734 | PubMed |
| 17 | 23783569 | Blood vessels are concentrated within the implant surface concavities: a histologic study in rabbit tibia. | Odontology | 2014 | https://conductscience.org/library/papers/23783569 | PubMed |
| 18 | 37512339 | A Comparison of Conical and Cylindrical Implants Inserted in an In Vitro Post-Extraction Model Using Low-Density Polyurethane Foam Blocks. | Materials (Basel) | 2023 | https://conductscience.org/library/papers/37512339 | PubMed |
| 19 | 32800579 | Addition of an irrigation channel to a surgical template to facilitate cooling during implant osteotomy. | J Prosthet Dent | 2021 | https://conductscience.org/library/papers/32800579 | PubMed |
| 20 | 18384409 | Two alternative surgical techniques for enhancing primary implant stability in the posterior maxilla: a clinical study including bone density, insertion torque, and resonance frequency analysis data. | Clin Implant Dent Relat Res | 2008 | https://conductscience.org/library/papers/18384409 | PubMed |
Cited by4
The papers in our copy of PubMed whose reference list names this one, newest first. iCite, which reads more sources, counts 4 citations.
| PMID | Title | Journal | Year | In Papers | Source |
|---|---|---|---|---|---|
| 41299363 | Primary and secondary stability in implants placed in low-density bone using conventional vs. osseodensification technique: a systematic review and meta-analysis. | BMC Oral Health | 2025 | https://conductscience.org/library/papers/41299363 | PubMed |
| 40271905 | Finite Element Analysis of Implant Stability Quotient (ISQ) and Bone Stresses for Implant Inclinations of 0°, 15°, and 20°. | Materials (Basel) | 2025 | https://conductscience.org/library/papers/40271905 | PubMed |
| 39851327 | Biomechanical Analysis of Truncated Cone Implants for Maxillary Sinus Lift: An In Vitro Study on Polyurethane Laminas. | Bioengineering (Basel) | 2025 | https://conductscience.org/library/papers/39851327 | PubMed |
| 39597348 | Microscopic Analysis and Evaluation of Thermal Elevation and Wear of Drills for Implant Site Preparation: An In Vitro Study. | Materials (Basel) | 2024 | https://conductscience.org/library/papers/39597348 | PubMed |
Data dates
The date of each source this release read.
- Trials
- 2026-11-12
- Gene search
- 2026-11-11
- Pipelines
- 2026-09-18
None in this release
- Grants
- Trials
- Comments and corrections
- Genes
- Drugs
- Data
Sources 11
- ChEMBL, through Open TargetsCC BY-SA 3.0
- ClinicalTrials.govNo license stated
- HGNCCC0
- iCiteCC BY 4.0
- NCBI GenePublic domain (US government)
- NIH RePORTER's grant and paper linksPublic domain
- Open TargetsCC0 1.0
- PMC's ID filePublic domain (US government)
- PubMedNLM's terms
- PubTator 3Public domain
- UniProtCC BY 4.0
Each source's terms
- ChEMBL, through Open TargetsCC BY-SA 3.0, for the parts from ChEMBL. Read on 8 Nov 2026 at https://platform-docs.opentargets.org/licence
- ClinicalTrials.govnone stated
- HGNCCC0: https://www.genenames.org/about/license/
- iCiteCC BY 4.0
- NCBI GeneNone named for the file. NCBI says information created by or for the US government on its site is in the public domain, and asks that NLM be acknowledged: https://www.ncbi.nlm.nih.gov/home/about/policies/
- NIH RePORTER's grant and paper linksPublic domain (NIH RePORTER)
- Open TargetsCC0 1.0. Open Targets asks that users cite its latest paper: Buniello et al. 2025, Open Targets Platform: facilitating therapeutic hypotheses building in drug discovery, Nucleic Acids Research 53(D1):D1467, PMID 39657122. Read on 8 Nov 2026 at https://platform-docs.opentargets.org/licence
- PMC's ID fileNone named for the file. NCBI says information created by or for the US government on its site is in the public domain, and asks that NLM be acknowledged: https://www.ncbi.nlm.nih.gov/home/about/policies/
- PubMedNLM's terms
- PubTator 3Public domain
- UniProtCC BY 4.0. UniProt's licence file: "All databases and documents in the UniProt FTP directory may be copied and redistributed freely, without advance permission, provided that this copyright statement is reproduced with each copy." UniProt asks that users cite its latest paper: The UniProt Consortium, UniProt: the Universal Protein Knowledgebase in 2025, Nucleic Acids Research 53:D609-D617, https://doi.org/10.1093/nar/gkae1010. Read on 9 Nov 2026 at https://www.uniprot.org/help/license
ClinicalTrials.gov's data carry an international copyright outside the United States: https://clinicaltrials.gov/about-site/terms-conditions.
For software
Read this paper from software.
The record and each of its lists are JSON, twenty rows a page. No key.
GET https://conductscience.org/api/papers/v1/39170202
GET https://conductscience.org/api/papers/v1/39170202/references?page=2