ConductScience.org, home

Paper39440428

Multicenter Hemodynamic Assessment of the LOT-CRT Strategy: When Does Combining Left Bundle Branch Pacing and Coronary Venous Pacing Enhance Resynchronization?: Primary Results of the CSPOT Study.

Jastrzębski M and 16 others. Circ Arrhythm Electrophysiol, 2024. Cited by 57 papers, by iCite.

Cite this record

ConductScience Library. Multicenter Hemodynamic Assessment of the LOT-CRT Strategy: When Does Combining Left Bundle Branch Pacing and Coronary Venous Pacing Enhance Resynchronization?: Primary Results of the CSPOT Study. Papers, record 39440428. Release papers-2026-11-12-0.1.0, 12 Nov 2026. https://conductscience.org/library/papers/39440428

Download JSON
Sources
11 sources
Release
papers-2026-11-12-0.1.0

Paper

PubMed's record of the paper, with iCite's citation figures. No abstract is shown.

Title
Multicenter Hemodynamic Assessment of the LOT-CRT Strategy: When Does Combining Left Bundle Branch Pacing and Coronary Venous Pacing Enhance Resynchronization?: Primary Results of the CSPOT Study.
PubMed
Journal
Circ Arrhythm Electrophysiol
PubMed
Year
2024
PubMed
Publication types
Journal Article, Multicenter Study, Comparative Study
PubMed
Citations, by iCite
57
iCite
Relative citation ratio, by iCite
12.56, provisional
iCite
Revised in PubMed
2025-01-28
PubMed

Authors17

The authors in the order PubMed's record lists them, with the ORCID iDs it states.

Source PubMed

Download CSV of authors

Topics19

NLM's MeSH indexing of the paper, its major topics first.

MeSH termMajor
Cardiac Resynchronization TherapyMajor topic
Bundle-Branch BlockMajor topic
Ventricular Function, LeftMajor topic
HemodynamicsMajor topic
ElectrocardiographyMajor topic
Humans
Male
Female
Aged
Treatment Outcome
Middle Aged
Bundle of His
Heart Rate
Heart Failure
Time Factors
Action Potentials
Ventricular Pressure
Prospective Studies
United States

Source PubMed

Download CSV of topics

Trials2

The trials whose ClinicalTrials.gov record lists the paper, and the trial numbers the paper's PubMed record names.

TrialTitleThe trial lists it asNamed in the paper's recordSource
NCT04905290Conduction System Pacing Optimized TherapyDerived from the trialYesClinicalTrials.gov
NCT07664189LBBP + CSP Versus LBBP Alone for Cardiac Resynchronization TherapyBackgroundClinicalTrials.gov

Download CSV of trials

References46

The papers the reference list in PubMed's record names, those in our copy of PubMed, in the list's order.

OrderPMIDTitleJournalYearIn PapersSource
131537329Hemodynamic Optimization in Cardiac Resynchronization Therapy: Should We Aim for dP/dtmax or Stroke Work?JACC Clin Electrophysiol2019https://conductscience.org/library/papers/31537329PubMed
230412778
2018 ACC/AHA/HRS guideline on the evaluation and management of patients with bradycardia and cardiac conduction delay: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines and the Heart Rhythm Society.
Heart Rhythm2019https://conductscience.org/library/papers/30412778PubMed
335070699Deep septal pacing to upgrade patients with pacing-induced cardiomyopathy.HeartRhythm Case Rep2022https://conductscience.org/library/papers/35070699PubMed
437950738Arrhythmic Risk in Biventricular Pacing Compared With Left Bundle Branch Area Pacing: Results From the I-CLAS Study.Circulation2024https://conductscience.org/library/papers/37950738PubMed
534490382Mechanical Synchrony and Myocardial Work in Heart Failure Patients With Left Bundle Branch Area Pacing and Comparison With Biventricular Pacing.Front Cardiovasc Med2021https://conductscience.org/library/papers/34490382PubMed
630403774Cardiac resynchronization therapy-induced acute shortening of QRS duration predicts long-term mortality only in patients with left bundle branch block.Europace2019https://conductscience.org/library/papers/30403774PubMed
737343033Clinical outcomes of conduction system pacing versus biventricular pacing for cardiac resynchronization therapy: A systematic review and meta-analysis.J Cardiovasc Electrophysiol2023https://conductscience.org/library/papers/37343033PubMed
815152059Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure.N Engl J Med2004https://conductscience.org/library/papers/15152059PubMed
912063368Cardiac resynchronization in chronic heart failure.N Engl J Med2002https://conductscience.org/library/papers/12063368PubMed
1037061850
EHRA clinical consensus statement on conduction system pacing implantation: executive summary. Endorsed by the Asia-Pacific Heart Rhythm Society (APHRS), Canadian Heart Rhythm Society (CHRS) and Latin-American Heart Rhythm Society (LAHRS).
Europace2023https://conductscience.org/library/papers/37061850PubMed
1118458170Results of the Predictors of Response to CRT (PROSPECT) trial.Circulation2008https://conductscience.org/library/papers/18458170PubMed
1232000945Short-Term Hemodynamic and Electrophysiological Effects of Cardiac Resynchronization by Left Ventricular Septal Pacing.J Am Coll Cardiol2020https://conductscience.org/library/papers/32000945PubMed
1335647062
Acute Hemodynamic Effects of Simultaneous and Sequential Multi-Point Pacing in Heart Failure Patients With an Expected Higher Rate of Sub-response to Cardiac Resynchronization Therapy: Results of Multicenter SYNSEQ Study.
Front Cardiovasc Med2022https://conductscience.org/library/papers/35647062PubMed
1433476467Reduction in the QRS area after cardiac resynchronization therapy is associated with survival and echocardiographic response.J Cardiovasc Electrophysiol2021https://conductscience.org/library/papers/33476467PubMed
1534339851Left bundle branch-optimized cardiac resynchronization therapy (LOT-CRT): Results from an international LBBAP collaborative study group.Heart Rhythm2022https://conductscience.org/library/papers/34339851PubMed
1637815462Left bundle branch pacing with and without anodal capture: impact on ventricular activation pattern and acute haemodynamics.Europace2023https://conductscience.org/library/papers/37815462PubMed
1737477545Comparison of electrocardiographic parameters between left bundle optimized cardiac resynchronization therapy (LOT-CRT) and left bundle branch pacing-cardiac resynchronization therapy (LBBP-CRT).Pacing Clin Electrophysiol2023https://conductscience.org/library/papers/37477545PubMed
1821110226
When is an optimization not an optimization? Evaluation of clinical implications of information content (signal-to-noise ratio) in optimization of cardiac resynchronization therapy, and how to measure and maximize it.
Heart Fail Rev2011https://conductscience.org/library/papers/21110226PubMed
1938461922Comparisons of long-term clinical outcomes with left bundle branch pacing, left ventricular septal pacing, and biventricular pacing for cardiac resynchronization therapy.Heart Rhythm2024https://conductscience.org/library/papers/38461922PubMed
2019281930
AHA/ACCF/HRS recommendations for the standardization and interpretation of the electrocardiogram: part III: intraventricular conduction disturbances: a scientific statement from the American Heart Association Electrocardiography and Arrhythmias Committee, Council on Clinical Cardiology; the American College of Cardiology Foundation; and the Heart Rhythm Society. Endorsed by the International Society for Computerized Electrocardiology.
J Am Coll Cardiol2009https://conductscience.org/library/papers/19281930PubMed

See all 46 referencesDownload CSV of references

Cited by41

The papers in our copy of PubMed whose reference list names this one, newest first. iCite, which reads more sources, counts 57 citations.

PMIDTitleJournalYearIn PapersSource
42936037Optimization of nonresponders to left bundle branch area pacing using electrical dyssynchrony mapping.Heart Rhythm O22026https://conductscience.org/library/papers/42936037PubMed
42919988The evolution and future of conduction system pacing.Nat Rev Cardiol2026https://conductscience.org/library/papers/42919988PubMed
42783494Left Bundle Branch Area Pacing in Heart Failure: A Physiological Alternative to Conventional Biventricular Cardiac Resynchronization Therapy and a Step Towards Personalized Device Therapy.J Pers Med2026https://conductscience.org/library/papers/42783494PubMed
42678627Cardiac implantable electronic devices in heart failure: needs, challenges, and real-world implementation.Heart Fail Rev2026https://conductscience.org/library/papers/42678627PubMed
42582137Resynchronisation efficacy of pacing strategies depends on the assessment metric: a computational study.Front Physiol2026https://conductscience.org/library/papers/42582137PubMed
42452484Personalized Test Bolus MSCT Protocol for Optimal Coronary Sinus Venous Visualization in Candidates for Cardiac Resynchronization Therapy.J Clin Med2026https://conductscience.org/library/papers/42452484PubMed
42338632T Wave Oversensing in Left Bundle Branch Optimised CRT.Arrhythm Electrophysiol Rev2026https://conductscience.org/library/papers/42338632PubMed
42181120Ultra-high-frequency electrocardiography guided cardiac resynchronization therapy in a patient with an ambiguous electrocardiogram.HeartRhythm Case Rep2026https://conductscience.org/library/papers/42181120PubMed
42152765Conduction system pacing for cardiac resynchronization therapy: a systematic review.Europace2026https://conductscience.org/library/papers/42152765PubMed
42109833Left Bundle Branch Area Pacing vs. Biventricular Pacing for Cardiac Resynchronization: Propensity Score Analysis.J Arrhythm2026https://conductscience.org/library/papers/42109833PubMed
42085561Optimal pace timing for left bundle branch area pacing with or without an additional LV lead: results from the CSPOT study.Europace2026https://conductscience.org/library/papers/42085561PubMed
42043915Cardiac Resynchronization Therapy: A Review.JAMA2026https://conductscience.org/library/papers/42043915PubMed
41992559The Resynchronization Effect in Left Bundle Branch Pacing Can be Evaluated Non-Invasively With the Implementation of Lead V8.J Cardiovasc Electrophysiol2026https://conductscience.org/library/papers/41992559PubMed
41811342Long-Term Outcomes of Left Bundle-Branch Pacing vs Biventricular Pacing in Heart Failure: The HeartSync-LBBP Randomized Clinical Trial.JAMA Cardiol2026https://conductscience.org/library/papers/41811342PubMed
41748070Left Bundle Branch Block in Non-Ischemic Cardiomyopathy: Does LOT-CRT offer incremental benefit compared to LBBP?Indian Pacing Electrophysiol J2026https://conductscience.org/library/papers/41748070PubMed
41732466Severe deterioration of left ventricular function after left bundle branch area pacing: A rare case report.HeartRhythm Case Rep2026https://conductscience.org/library/papers/41732466PubMed
41698465Left bundle cardiac resynchronization therapy versus left bundle optimized cardiac resynchronization therapy.Indian Pacing Electrophysiol J2026https://conductscience.org/library/papers/41698465PubMed
41676928Left Bundle-Branch Capture Not Confirmed During the Implant: What Is the Next Best Step?J Am Heart Assoc2026https://conductscience.org/library/papers/41676928PubMed
41561776
A case report: SPEAR-CRT: first description of use of left bundle branch area pacing tools and techniques to place an endocardial LV lead via the interventricular septum in a patient with ostial coronary sinus occlusion.
Eur Heart J Case Rep2026https://conductscience.org/library/papers/41561776PubMed
41554636Innovations in cardiac device therapy in the era of advanced rhythm management: implantable defibrillators and conduction system pacing.Heart2026https://conductscience.org/library/papers/41554636PubMed

See all 41 cited byDownload CSV of cited by

Data dates

The date of each source this release read.

PubMed
2026-11-06
PubMed
iCite
2026-11-05
iCite
PMC's ID file
2026-11-05
PMC's ID file
NIH RePORTER's grant and paper links
2026-11-01
NIH RePORTER's grant and paper links
Trials
2026-11-12
Gene search
2026-11-11
Pipelines
2026-09-18

None in this release

  • Grants
  • Comments and corrections
  • Genes
  • Drugs
  • Data

Sources 11

  • ChEMBL, through Open TargetsCC BY-SA 3.0
  • ClinicalTrials.govNo license stated
  • HGNCCC0
  • iCiteCC BY 4.0
  • NCBI GenePublic domain (US government)
  • NIH RePORTER's grant and paper linksPublic domain
  • Open TargetsCC0 1.0
  • PMC's ID filePublic domain (US government)
  • PubMedNLM's terms
  • PubTator 3Public domain
  • UniProtCC BY 4.0
Each source's terms
  • ChEMBL, through Open TargetsCC BY-SA 3.0, for the parts from ChEMBL. Read on 8 Nov 2026 at https://platform-docs.opentargets.org/licence
  • ClinicalTrials.govnone stated
  • HGNCCC0: https://www.genenames.org/about/license/
  • iCiteCC BY 4.0
  • NCBI GeneNone named for the file. NCBI says information created by or for the US government on its site is in the public domain, and asks that NLM be acknowledged: https://www.ncbi.nlm.nih.gov/home/about/policies/
  • NIH RePORTER's grant and paper linksPublic domain (NIH RePORTER)
  • Open TargetsCC0 1.0. Open Targets asks that users cite its latest paper: Buniello et al. 2025, Open Targets Platform: facilitating therapeutic hypotheses building in drug discovery, Nucleic Acids Research 53(D1):D1467, PMID 39657122. Read on 8 Nov 2026 at https://platform-docs.opentargets.org/licence
  • PMC's ID fileNone named for the file. NCBI says information created by or for the US government on its site is in the public domain, and asks that NLM be acknowledged: https://www.ncbi.nlm.nih.gov/home/about/policies/
  • PubMedNLM's terms
  • PubTator 3Public domain
  • UniProtCC BY 4.0. UniProt's licence file: "All databases and documents in the UniProt FTP directory may be copied and redistributed freely, without advance permission, provided that this copyright statement is reproduced with each copy." UniProt asks that users cite its latest paper: The UniProt Consortium, UniProt: the Universal Protein Knowledgebase in 2025, Nucleic Acids Research 53:D609-D617, https://doi.org/10.1093/nar/gkae1010. Read on 9 Nov 2026 at https://www.uniprot.org/help/license

ClinicalTrials.gov's data carry an international copyright outside the United States: https://clinicaltrials.gov/about-site/terms-conditions.

For software

Read this paper from software.

The record and each of its lists are JSON, twenty rows a page. No key.

GET https://conductscience.org/api/papers/v1/39440428

GET https://conductscience.org/api/papers/v1/39440428/references?page=2