Paper39733131
Endograft-specific hemodynamics after endovascular aneurysm repair: a CFD analysis.
Zhang Y and 8 others. Sci Rep, 2024. Cited by 6 papers, by iCite.
Cite this record
ConductScience Library. Endograft-specific hemodynamics after endovascular aneurysm repair: a CFD analysis. Papers, record 39733131. Release papers-2026-11-12-0.1.0, 12 Nov 2026. https://conductscience.org/library/papers/39733131
- Sources
- 11 sources
- Release
- papers-2026-11-12-0.1.0
Paper
PubMed's record of the paper, with iCite's citation figures. No abstract is shown.
Topics13
NLM's MeSH indexing of the paper, its major topics first.
| MeSH term | Major |
|---|---|
| Hemodynamics | Major topic |
| Endovascular Procedures | Major topic |
| Iliac Artery | Major topic |
| Humans | |
| Blood Flow Velocity | |
| Blood Vessel Prosthesis | |
| Stents | |
| Hydrodynamics | |
| Models, Cardiovascular | |
| Aortic Aneurysm, Abdominal | |
| Blood Vessel Prosthesis Implantation | |
| Stress, Mechanical | |
| Endovascular Aneurysm Repair |
Source PubMed
Grants5
Each grant PubMed's record writes, matched to the NIH project NIH's grant and paper links name for this paper, and each of those links the record does not write.
| Grant, as the record writes it | Agency | Country | NIH project | Stated by |
|---|---|---|---|---|
| JYLJ202204 | Clinical Research Program of 9th People's Hospital | PubMed | ||
| 21S31904300 | Shanghai Science and Technology Innovation Action Plan | PubMed | ||
| 20224Y0170 | Shanghai Municipal Health Bureau Project | PubMed | ||
| No.JYYC004 | Original Exploration Project of Shanghai Ninth People's Hospital | PubMed | ||
| 82300540 | National Natural Science Foundation of China | PubMed |
Source PubMed
References33
The papers the reference list in PubMed's record names, those in our copy of PubMed, in the list's order.
| Order | PMID | Title | Journal | Year | In Papers | Source |
|---|---|---|---|---|---|---|
| 1 | 15047000 | Non-Newtonian blood flow in human right coronary arteries: steady state simulations. | J Biomech | 2004 | https://conductscience.org/library/papers/15047000 | PubMed |
| 2 | 25267572 | Patient-specific analysis of displacement forces acting on fenestrated stent grafts for endovascular aneurysm repair. | J Biomech | 2014 | https://conductscience.org/library/papers/25267572 | PubMed |
| 3 | 22511690 | Comparison of long-term survival after open vs endovascular repair of intact abdominal aortic aneurysm among Medicare beneficiaries. | JAMA | 2012 | https://conductscience.org/library/papers/22511690 | PubMed |
| 4 | 33969018 | Hemodynamic Parameters Predict In-stent Thrombosis After Multibranched Endovascular Repair of Complex Abdominal Aortic Aneurysms: A Retrospective Study of Branched Stent-Graft Thrombosis. | Front Cardiovasc Med | 2021 | https://conductscience.org/library/papers/33969018 | PubMed |
| 5 | 18818100 | Mural thrombotic deposits in abdominal aortic endografts are common and do not require additional treatment at short-term and midterm follow-up. | J Vasc Interv Radiol | 2008 | https://conductscience.org/library/papers/18818100 | PubMed |
| 6 | 29268916 | The Society for Vascular Surgery practice guidelines on the care of patients with an abdominal aortic aneurysm. | J Vasc Surg | 2018 | https://conductscience.org/library/papers/29268916 | PubMed |
| 7 | 20499185 | Flow residence time and regions of intraluminal thrombus deposition in intracranial aneurysms. | Ann Biomed Eng | 2010 | https://conductscience.org/library/papers/20499185 | PubMed |
| 8 | 34210099 | Structural Design of Vascular Stents: A Review. | Micromachines (Basel) | 2021 | https://conductscience.org/library/papers/34210099 | PubMed |
| 9 | 32394221 | Efficiently Simulating an Endograft Deployment: A Methodology for Detailed CFD Analyses. | Ann Biomed Eng | 2020 | https://conductscience.org/library/papers/32394221 | PubMed |
| 10 | 25736781 | Clinical outcome and morphologic determinants of mural thrombus in abdominal aortic endografts. | J Vasc Surg | 2015 | https://conductscience.org/library/papers/25736781 | PubMed |
| 11 | 17684097 | Spatio-temporal analysis of eukaryotic cell motility by improved force cytometry. | Proc Natl Acad Sci U S A | 2007 | https://conductscience.org/library/papers/17684097 | PubMed |
| 12 | 32147117 | Endovascular Abdominal Aortic Aneurysm Repair. | Interv Cardiol Clin | 2020 | https://conductscience.org/library/papers/32147117 | PubMed |
| 13 | 15863346 | Blood flow and structure interactions in a stented abdominal aortic aneurysm model. | Med Eng Phys | 2005 | https://conductscience.org/library/papers/15863346 | PubMed |
| 14 | 20162359 | AAA stent-grafts: past problems and future prospects. | Ann Biomed Eng | 2010 | https://conductscience.org/library/papers/20162359 | PubMed |
| 15 | 25326533 | A longitudinal comparison of hemodynamics and intraluminal thrombus deposition in abdominal aortic aneurysms. | Am J Physiol Heart Circ Physiol | 2014 | https://conductscience.org/library/papers/25326533 | PubMed |
| 16 | 30012445 | Significance and Risk Factors for Intraprosthetic Mural Thrombus in Abdominal Aortic Endografts: A Systematic Review and Meta-analysis. | Ann Vasc Surg | 2018 | https://conductscience.org/library/papers/30012445 | PubMed |
| 17 | 11755809 | Fluid-structure interaction within realistic three-dimensional models of the aneurysmatic aorta as a guidance to assess the risk of rupture of the aneurysm. | Med Eng Phys | 2001 | https://conductscience.org/library/papers/11755809 | PubMed |
| 18 | 32241093 | Prevalence, risk factors and clinical impact of intraprosthetic thrombus deposits after EVAR. | J Cardiovasc Surg (Torino) | 2020 | https://conductscience.org/library/papers/32241093 | PubMed |
| 19 | 31948772 | A computational fluid dynamics analysis of a patient with acute non-A-non-B aortic dissection after type I hybrid arch repair. | Med Eng Phys | 2020 | https://conductscience.org/library/papers/31948772 | PubMed |
| 20 | 21422389 | Stent thrombogenicity early in high-risk interventional settings is driven by stent design and deployment and protected by polymer-drug coatings. | Circulation | 2011 | https://conductscience.org/library/papers/21422389 | PubMed |
Cited by4
The papers in our copy of PubMed whose reference list names this one, newest first. iCite, which reads more sources, counts 6 citations.
| PMID | Title | Journal | Year | In Papers | Source |
|---|---|---|---|---|---|
| 42004608 | Abdominal Stent Graft Numerical Models to Virtually Simulate Endovascular Aortic Repair: A Scoping Review. | EJVES Vasc Forum | 2026 | https://conductscience.org/library/papers/42004608 | PubMed |
| 41977327 | Total Thrombus-Formation Analysis System (T-TAS) in Aortopathies: A Conceptual and Potential Framework to Spatial Heterogeneity and Regional Context. | Int J Mol Sci | 2026 | https://conductscience.org/library/papers/41977327 | PubMed |
| 41463676 | Using Patient-Based Computational Fluid Dynamics for Abdominal Aortic Aneurysm Assessment. | Bioengineering (Basel) | 2025 | https://conductscience.org/library/papers/41463676 | PubMed |
| 40004819 | Computational Fluid Dynamics-Driven Comparison of Endovascular Treatment Strategies for Penetrating Aortic Ulcer. | J Clin Med | 2025 | https://conductscience.org/library/papers/40004819 | PubMed |
Data dates
The date of each source this release read.
- Trials
- 2026-11-12
- Gene search
- 2026-11-11
- Pipelines
- 2026-09-18
None in this release
- Trials
- Comments and corrections
- Genes
- Drugs
- Data
Sources 11
- ChEMBL, through Open TargetsCC BY-SA 3.0
- ClinicalTrials.govNo license stated
- HGNCCC0
- iCiteCC BY 4.0
- NCBI GenePublic domain (US government)
- NIH RePORTER's grant and paper linksPublic domain
- Open TargetsCC0 1.0
- PMC's ID filePublic domain (US government)
- PubMedNLM's terms
- PubTator 3Public domain
- UniProtCC BY 4.0
Each source's terms
- ChEMBL, through Open TargetsCC BY-SA 3.0, for the parts from ChEMBL. Read on 8 Nov 2026 at https://platform-docs.opentargets.org/licence
- ClinicalTrials.govnone stated
- HGNCCC0: https://www.genenames.org/about/license/
- iCiteCC BY 4.0
- NCBI GeneNone named for the file. NCBI says information created by or for the US government on its site is in the public domain, and asks that NLM be acknowledged: https://www.ncbi.nlm.nih.gov/home/about/policies/
- NIH RePORTER's grant and paper linksPublic domain (NIH RePORTER)
- Open TargetsCC0 1.0. Open Targets asks that users cite its latest paper: Buniello et al. 2025, Open Targets Platform: facilitating therapeutic hypotheses building in drug discovery, Nucleic Acids Research 53(D1):D1467, PMID 39657122. Read on 8 Nov 2026 at https://platform-docs.opentargets.org/licence
- PMC's ID fileNone named for the file. NCBI says information created by or for the US government on its site is in the public domain, and asks that NLM be acknowledged: https://www.ncbi.nlm.nih.gov/home/about/policies/
- PubMedNLM's terms
- PubTator 3Public domain
- UniProtCC BY 4.0. UniProt's licence file: "All databases and documents in the UniProt FTP directory may be copied and redistributed freely, without advance permission, provided that this copyright statement is reproduced with each copy." UniProt asks that users cite its latest paper: The UniProt Consortium, UniProt: the Universal Protein Knowledgebase in 2025, Nucleic Acids Research 53:D609-D617, https://doi.org/10.1093/nar/gkae1010. Read on 9 Nov 2026 at https://www.uniprot.org/help/license
ClinicalTrials.gov's data carry an international copyright outside the United States: https://clinicaltrials.gov/about-site/terms-conditions.
For software
Read this paper from software.
The record and each of its lists are JSON, twenty rows a page. No key needed for records and first pages, up to 100 calls a day. With a free key, your account gets 2,000 a day and every page.
GET https://conductscience.org/api/papers/v1/39733131
GET https://conductscience.org/api/papers/v1/39733131/references?page=2