Paper41274191
Effect of stent-graft length and compliance on aortic hemodynamics in a bench-top physiological flow circuit.
Shahbad R and 5 others. J Mech Behav Biomed Mater, 2026. Cited by 5 papers, by iCite.
Cite this record
ConductScience Library. Effect of stent-graft length and compliance on aortic hemodynamics in a bench-top physiological flow circuit. Papers, record 41274191. Release papers-2026-11-12-0.1.0, 12 Nov 2026. https://conductscience.org/library/papers/41274191
- Sources
- 11 sources
- Release
- papers-2026-11-12-0.1.0
Paper
PubMed's record of the paper, with iCite's citation figures. No abstract is shown.
- Title
- Effect of stent-graft length and compliance on aortic hemodynamics in a bench-top physiological flow circuit.
- PubMed
Topics8
NLM's MeSH indexing of the paper, its major topics first.
| MeSH term | Major |
|---|---|
| Stents | Major topic |
| Aorta | Major topic |
| Hemodynamics | Major topic |
| Blood Vessel Prosthesis | Major topic |
| Compliance | |
| Materials Testing | |
| Pulsatile Flow | |
| Nanofibers |
Source PubMed
Grants2
Each grant PubMed's record writes, matched to the NIH project NIH's grant and paper links name for this paper, and each of those links the record does not write.
| Grant, as the record writes it | Agency | Country | NIH project | Stated by | Source |
|---|---|---|---|---|---|
| P20 GM152301 | NIGMS NIH HHS | United States | P20GM152301 | PubMed | NIH RePORTER |
| R01 HL147128 | NHLBI NIH HHS | United States | R01HL147128 | PubMed | NIH RePORTER |
References60
The papers the reference list in PubMed's record names, those in our copy of PubMed, in the list's order.
| Order | PMID | Title | Journal | Year | In Papers | Source |
|---|---|---|---|---|---|---|
| 1 | 19853098 | A comparison of mechanical properties of materials used in aortic arch reconstruction. | Ann Thorac Surg | 2009 | https://conductscience.org/library/papers/19853098 | PubMed |
| 2 | 28597335 | Effect of endoskeleton stent graft design on pulse wave velocity in patients undergoing endovascular repair of the aortic arch. | Gen Thorac Cardiovasc Surg | 2017 | https://conductscience.org/library/papers/28597335 | PubMed |
| 3 | 19342960 | Effect of abdominal aortic grafts on aortic stiffness and central hemodynamics. | J Hypertens | 2009 | https://conductscience.org/library/papers/19342960 | PubMed |
| 4 | 31904600 | Endovascular Repair of Blunt Thoracic Aortic Trauma is Associated With Increased Left Ventricular Mass, Hypertension, and Off-target Aortic Remodeling. | Ann Surg | 2021 | https://conductscience.org/library/papers/31904600 | PubMed |
| 5 | 25516162 | Evaluation of filtering methods for acquiring radial intra-artery blood pressure waveforms. | J Clin Monit Comput | 2015 | https://conductscience.org/library/papers/25516162 | PubMed |
| 6 | 30215614 | Effect of abdominal aortic endoprostheses on arterial pulse wave velocity in an in vitro abdominal aortic flow model. | Physiol Meas | 2018 | https://conductscience.org/library/papers/30215614 | PubMed |
| 7 | 23218139 | Stent graft performance in the treatment of abdominal aortic aneurysms: the influence of compliance and geometry. | J Biomech | 2013 | https://conductscience.org/library/papers/23218139 | PubMed |
| 8 | 24136338 | Axial prestretch and circumferential distensibility in biomechanics of abdominal aorta. | Biomech Model Mechanobiol | 2014 | https://conductscience.org/library/papers/24136338 | PubMed |
| 9 | 7930267 | Chronically decreased aortic distensibility causes deterioration of coronary perfusion during increased left ventricular contraction. | J Am Coll Cardiol | 1994 | https://conductscience.org/library/papers/7930267 | PubMed |
| 10 | 22230116 | Bramwell-Hill modeling for local aortic pulse wave velocity estimation: a validation study with velocity-encoded cardiovascular magnetic resonance and invasive pressure assessment. | J Cardiovasc Magn Reson | 2012 | https://conductscience.org/library/papers/22230116 | PubMed |
| 11 | 7786838 | Elastic properties and Windkessel function of the human aorta. | Cardiovasc Drugs Ther | 1995 | https://conductscience.org/library/papers/7786838 | PubMed |
| 12 | 24292128 | Endovascular aortic repair increases vascular stiffness and alters cardiac structure and function. | Circ J | 2014 | https://conductscience.org/library/papers/24292128 | PubMed |
| 13 | 27876124 | Estimating the influence of aortic-stent grafts after endovascular aneurysm repair: Are we missing something? | Med Hypotheses | 2016 | https://conductscience.org/library/papers/27876124 | PubMed |
| 14 | 23046333 | Changes in aortic pulse wave velocity of patients undergoing endovascular repair of abdominal aortic aneurysms. | J Endovasc Ther | 2012 | https://conductscience.org/library/papers/23046333 | PubMed |
| 15 | 31344466 | Cardiovascular Remodeling after Endovascular Treatment for Thoracic Aortic Injury. | Ann Vasc Surg | 2019 | https://conductscience.org/library/papers/31344466 | PubMed |
| 16 | 36849029 | Global and local stiffening of ex vivo-perfused stented human thoracic aortas: A mock circulation study. | Acta Biomater | 2023 | https://conductscience.org/library/papers/36849029 | PubMed |
| 17 | 33549808 | Mechanically tuned vascular graft demonstrates rapid endothelialization and integration into the porcine iliac artery wall. | Acta Biomater | 2021 | https://conductscience.org/library/papers/33549808 | PubMed |
| 18 | 17383803 | Measurement of local pulse wave velocity: effects of signal processing on precision. | Ultrasound Med Biol | 2007 | https://conductscience.org/library/papers/17383803 | PubMed |
| 19 | 26798761 | Arterial Stiffness Alterations and Inflammatory Response Following Endovascular Aortic Repair: Based on a Presentation at the 2013 VEITH Symposium, November 19-23, 2013 (New York, NY, USA). | Aorta (Stamford) | 2015 | https://conductscience.org/library/papers/26798761 | PubMed |
| 20 | 36444831 | Aortic Distensibility Measured by Automated Analysis of Magnetic Resonance Imaging Predicts Adverse Cardiovascular Events in UK Biobank. | J Am Heart Assoc | 2022 | https://conductscience.org/library/papers/36444831 | PubMed |
Cited by7
The papers in our copy of PubMed whose reference list names this one, newest first. iCite, which reads more sources, counts 5 citations.
| PMID | Title | Journal | Year | In Papers | Source |
|---|---|---|---|---|---|
| 42932223 | From structural repair to biomechanical compatibility: Aortic stiffness after open and endovascular aortic repair. | Exp Physiol | 2026 | https://conductscience.org/library/papers/42932223 | PubMed |
| 42617781 | Revisiting the tension-free paradigm: Axially prestretched elastomeric nanofibrillar grafts restore artery-like axial biomechanics in a preclinical model. | Acta Biomater | 2026 | https://conductscience.org/library/papers/42617781 | PubMed |
| 42472829 | Rare coexistence of isolated celiac artery dissection and superior mesenteric artery dissection: diagnosis, treatment, follow-up outcomes of a single patient and clinical implications. | J Cardiothorac Surg | 2026 | https://conductscience.org/library/papers/42472829 | PubMed |
| 41827430 | Femoral Plaque Burden and Left Ventricular-Arterial Coupling in Patients with Chronic Heart Failure. | J Clin Med | 2026 | https://conductscience.org/library/papers/41827430 | PubMed |
| 41730346 | Stent-graft compliance modulates regional mechanical and structural remodeling of the aorta. | Acta Biomater | 2026 | https://conductscience.org/library/papers/41730346 | PubMed |
| 41708050 | Windkessel Preserving Aortic Stent Graft Attenuates Left Ventricular Remodelling after Thoracic Endovascular Aortic Repair in a Porcine Model. | Eur J Vasc Endovasc Surg | 2026 | https://conductscience.org/library/papers/41708050 | PubMed |
| 41314447 | Effect of stent-graft compliance on hemodynamics and aortic stiffening in an in vivo porcine study. | Acta Biomater | 2026 | https://conductscience.org/library/papers/41314447 | PubMed |
Data dates
The date of each source this release read.
- Trials
- 2026-11-12
- Gene search
- 2026-11-11
- Pipelines
- 2026-09-18
None in this release
- Trials
- Comments and corrections
- Genes
- Drugs
- Data
Sources 11
- ChEMBL, through Open TargetsCC BY-SA 3.0
- ClinicalTrials.govNo license stated
- HGNCCC0
- iCiteCC BY 4.0
- NCBI GenePublic domain (US government)
- NIH RePORTER's grant and paper linksPublic domain
- Open TargetsCC0 1.0
- PMC's ID filePublic domain (US government)
- PubMedNLM's terms
- PubTator 3Public domain
- UniProtCC BY 4.0
Each source's terms
- ChEMBL, through Open TargetsCC BY-SA 3.0, for the parts from ChEMBL. Read on 8 Nov 2026 at https://platform-docs.opentargets.org/licence
- ClinicalTrials.govnone stated
- HGNCCC0: https://www.genenames.org/about/license/
- iCiteCC BY 4.0
- NCBI GeneNone named for the file. NCBI says information created by or for the US government on its site is in the public domain, and asks that NLM be acknowledged: https://www.ncbi.nlm.nih.gov/home/about/policies/
- NIH RePORTER's grant and paper linksPublic domain (NIH RePORTER)
- Open TargetsCC0 1.0. Open Targets asks that users cite its latest paper: Buniello et al. 2025, Open Targets Platform: facilitating therapeutic hypotheses building in drug discovery, Nucleic Acids Research 53(D1):D1467, PMID 39657122. Read on 8 Nov 2026 at https://platform-docs.opentargets.org/licence
- PMC's ID fileNone named for the file. NCBI says information created by or for the US government on its site is in the public domain, and asks that NLM be acknowledged: https://www.ncbi.nlm.nih.gov/home/about/policies/
- PubMedNLM's terms
- PubTator 3Public domain
- UniProtCC BY 4.0. UniProt's licence file: "All databases and documents in the UniProt FTP directory may be copied and redistributed freely, without advance permission, provided that this copyright statement is reproduced with each copy." UniProt asks that users cite its latest paper: The UniProt Consortium, UniProt: the Universal Protein Knowledgebase in 2025, Nucleic Acids Research 53:D609-D617, https://doi.org/10.1093/nar/gkae1010. Read on 9 Nov 2026 at https://www.uniprot.org/help/license
ClinicalTrials.gov's data carry an international copyright outside the United States: https://clinicaltrials.gov/about-site/terms-conditions.
For software
Read this paper from software.
The record and each of its lists are JSON, twenty rows a page. No key.
GET https://conductscience.org/api/papers/v1/41274191
GET https://conductscience.org/api/papers/v1/41274191/references?page=2