ConductScience.org, home

Paper529796

Thermodilution cardiac output: a critical analysis and review of the literature.

Levett JM and 1 other. J Surg Res, 1979. Cited by 166 papers, by iCite.

Cite this record

ConductScience Library. Thermodilution cardiac output: a critical analysis and review of the literature. Papers, record 529796. Release papers-2026-11-12-0.1.0, 12 Nov 2026. https://conductscience.org/library/papers/529796

Sign in to download
Sources
11 sources
Release
papers-2026-11-12-0.1.0

Paper

PubMed's record of the paper, with iCite's citation figures. No abstract is shown.

Title
Thermodilution cardiac output: a critical analysis and review of the literature.
PubMed
Journal
J Surg Res
PubMed
Year
1979
PubMed
Publication types
Journal Article
PubMed
Citations, by iCite
166
iCite
Relative citation ratio, by iCite
10.3
iCite
Revised in PubMed
2019-08-17
PubMed

Authors2

The authors in the order PubMed's record lists them, with the ORCID iDs it states.

OrderAuthorForenameKindORCID iD
1Levett JMJ M
2Replogle RLR L

Source PubMed

Sign in to download

Topics5

NLM's MeSH indexing of the paper, its major topics first.

MeSH termMajor
Cardiac OutputMajor topic
ThermodilutionMajor topic
Body Temperature
Humans
Mathematics

Cited by36

The papers in our copy of PubMed whose reference list names this one, newest first. iCite, which reads more sources, counts 166 citations.

PMIDTitleJournalYearIn PapersSource
29121915Clinical monitoring of cardiac output assessed by transoesophageal echocardiography in anaesthetised dogs: a comparison with the thermodilution technique.BMC Vet Res2017https://conductscience.org/library/papers/29121915PubMed
25436024Variations in respiratory excretion of carbon dioxide can be used to calculate pulmonary blood flow.J Clin Med Res2015https://conductscience.org/library/papers/25436024PubMed
23748600The impact of systemic vascular resistance on the accuracy of the FloTrac/Vigileo™ system in the perioperative period of cardiac surgery: a prospective observational comparison study.J Clin Monit Comput2013https://conductscience.org/library/papers/23748600PubMed
21084673Modelflow underestimates cardiac output in heat-stressed individuals.Am J Physiol Regul Integr Comp Physiol2011https://conductscience.org/library/papers/21084673PubMed
20490574Can a NICO monitor substitute for thermodilution to measure cardiac output in patients with coexisting tricuspid regurgitation?J Anesth2010https://conductscience.org/library/papers/20490574PubMed
19057003Continuous cardiac output and left atrial pressure monitoring by long time interval analysis of the pulmonary artery pressure waveform: proof of concept in dogs.J Appl Physiol (1985)2009https://conductscience.org/library/papers/19057003PubMed
18443743Accuracy of continuous central venous oxygen saturation monitoring in patients undergoing cardiac surgery.J Clin Monit Comput2008https://conductscience.org/library/papers/18443743PubMed
18027068Gated single photon emission tomography MIBI stress perfusion imaging for assessing cardiac output and index in obese and non-obese patients.Ir J Med Sci2007https://conductscience.org/library/papers/18027068PubMed
17370126Accuracy of a novel approach to measuring arterial thermodilution cardiac output during intra-aortic counterpulsation.J Clin Monit Comput2007https://conductscience.org/library/papers/17370126PubMed
16255425Stroke volume equation for impedance cardiography.Med Biol Eng Comput2005https://conductscience.org/library/papers/16255425PubMed
12720564Comparison of bedside measurement of cardiac output with the thermodilution method and the Fick method in mechanically ventilated patients.Crit Care2003https://conductscience.org/library/papers/12720564PubMed
12580219Partial CO2 rebreathing indirect Fick technique for non-invasive measurement of cardiac output.J Clin Monit Comput2000https://conductscience.org/library/papers/12580219PubMed
9565813Markers of cellular dysoxia during orthotopic liver transplantation in pigs.Intensive Care Med1998https://conductscience.org/library/papers/9565813PubMed
9434918Non-invasive measurement of cardiac output: whole-body impedance cardiography in simultaneous comparison with thermodilution and direct oxygen Fick methods.Intensive Care Med1997https://conductscience.org/library/papers/9434918PubMed
9129248Movement of pulmonary artery catheters.Heart Vessels1996https://conductscience.org/library/papers/9129248PubMed
8708168Semi-continuous versus injectate cardiac output measurement in intensive care patients after cardiac surgery.Intensive Care Med1996https://conductscience.org/library/papers/8708168PubMed
8596064The discrepancy between echocardiography, cineventriculography and thermodilution. Evaluation of left ventricular volume and ejection fraction.Int J Card Imaging1995https://conductscience.org/library/papers/8596064PubMed
8522677The thermodilution method for the clinical assessment of cardiac output.Intensive Care Med1995https://conductscience.org/library/papers/8522677PubMed
8443853Errors in the measurement of cardiac output by thermodilution.Can J Anaesth1993https://conductscience.org/library/papers/8443853PubMed
7825341Cardiac output monitoring by echocardiography: should we pass on Swan-Ganz catheters?Yale J Biol Med1993https://conductscience.org/library/papers/7825341PubMed

See all 36 cited bySign in to download

Data dates

The date of each source this release read.

PubMed
2026-11-06
PubMed
iCite
2026-11-05
iCite
PMC's ID file
2026-11-05
PMC's ID file
NIH RePORTER's grant and paper links
2026-11-01
NIH RePORTER's grant and paper links
Trials
2026-11-12
Gene search
2026-11-11
Pipelines
2026-09-18

None in this release

  • Grants
  • Trials
  • Comments and corrections
  • References
  • Genes
  • Drugs
  • Data

Sources 11

  • ChEMBL, through Open TargetsCC BY-SA 3.0
  • ClinicalTrials.govNo license stated
  • HGNCCC0
  • iCiteCC BY 4.0
  • NCBI GenePublic domain (US government)
  • NIH RePORTER's grant and paper linksPublic domain
  • Open TargetsCC0 1.0
  • PMC's ID filePublic domain (US government)
  • PubMedNLM's terms
  • PubTator 3Public domain
  • UniProtCC BY 4.0
Each source's terms
  • ChEMBL, through Open TargetsCC BY-SA 3.0, for the parts from ChEMBL. Read on 8 Nov 2026 at https://platform-docs.opentargets.org/licence
  • ClinicalTrials.govnone stated
  • HGNCCC0: https://www.genenames.org/about/license/
  • iCiteCC BY 4.0
  • NCBI GeneNone named for the file. NCBI says information created by or for the US government on its site is in the public domain, and asks that NLM be acknowledged: https://www.ncbi.nlm.nih.gov/home/about/policies/
  • NIH RePORTER's grant and paper linksPublic domain (NIH RePORTER)
  • Open TargetsCC0 1.0. Open Targets asks that users cite its latest paper: Buniello et al. 2025, Open Targets Platform: facilitating therapeutic hypotheses building in drug discovery, Nucleic Acids Research 53(D1):D1467, PMID 39657122. Read on 8 Nov 2026 at https://platform-docs.opentargets.org/licence
  • PMC's ID fileNone named for the file. NCBI says information created by or for the US government on its site is in the public domain, and asks that NLM be acknowledged: https://www.ncbi.nlm.nih.gov/home/about/policies/
  • PubMedNLM's terms
  • PubTator 3Public domain
  • UniProtCC BY 4.0. UniProt's licence file: "All databases and documents in the UniProt FTP directory may be copied and redistributed freely, without advance permission, provided that this copyright statement is reproduced with each copy." UniProt asks that users cite its latest paper: The UniProt Consortium, UniProt: the Universal Protein Knowledgebase in 2025, Nucleic Acids Research 53:D609-D617, https://doi.org/10.1093/nar/gkae1010. Read on 9 Nov 2026 at https://www.uniprot.org/help/license

ClinicalTrials.gov's data carry an international copyright outside the United States: https://clinicaltrials.gov/about-site/terms-conditions.

For software

Read this paper from software.

The record and each of its lists are JSON, twenty rows a page. No key needed for records and first pages, up to 100 calls a day. With a free key, your account gets 2,000 a day and every page.

GET https://conductscience.org/api/papers/v1/529796

GET https://conductscience.org/api/papers/v1/529796/cited_by?page=2