ConductScience.org, home

Paper8425366

Determining the rotational alignment of the femoral component in total knee arthroplasty using the epicondylar axis.

Berger RA and 4 others. Clin Orthop Relat Res, 1993. Cited by 573 papers, by iCite.

Cite this record

ConductScience Library. Determining the rotational alignment of the femoral component in total knee arthroplasty using the epicondylar axis. Papers, record 8425366. Release papers-2026-11-12-0.1.0, 12 Nov 2026. https://conductscience.org/library/papers/8425366

Download JSON
Sources
11 sources
Release
papers-2026-11-12-0.1.0

Paper

PubMed's record of the paper, with iCite's citation figures. No abstract is shown.

Title
Determining the rotational alignment of the femoral component in total knee arthroplasty using the epicondylar axis.
PubMed
Journal
Clin Orthop Relat Res
PubMed
Year
1993
PubMed
Publication types
Journal Article
PubMed
Citations, by iCite
573
iCite
Relative citation ratio, by iCite
38.3
iCite
Revised in PubMed
2022-04-08
PubMed

Authors5

The authors in the order PubMed's record lists them, with the ORCID iDs it states.

OrderAuthorForenameKindORCID iD
1Berger RAR A
2Rubash HEH E
3Seel MJM J
4Thompson WHW H
5Crossett LSL S

Source PubMed

Download CSV of authors

Topics8

NLM's MeSH indexing of the paper, its major topics first.

MeSH termMajor
FemurMajor topic
Knee ProsthesisMajor topic
Biometry
Female
Humans
Male
Reoperation
Rotation

Source PubMed

Download CSV of topics

Trials1

The trials whose ClinicalTrials.gov record lists the paper, and the trial numbers the paper's PubMed record names.

TrialTitleThe trial lists it asNamed in the paper's record
NCT02071745Navigated Total Knee Arthroplasty, the Correlation to CT Scans and Clinical ResultsResults

Source ClinicalTrials.gov

Download CSV of trials

Cited by243

The papers in our copy of PubMed whose reference list names this one, newest first. iCite, which reads more sources, counts 573 citations.

PMIDTitleJournalYearIn PapersSource
42920968Post-Total Knee Arthroplasty Patellar Instability due to Extensor Mechanism Malalignment: A Novel Technique for Management.Arthroplast Today2026https://conductscience.org/library/papers/42920968PubMed
42355452Radiographic Accuracy and Consistency of Implant Placement Using the ROSA® Knee System in Robotic-Assisted Total Knee Arthroplasty: A Prospective Analysis.Life (Basel)2026https://conductscience.org/library/papers/42355452PubMed
42060141Thirty-year outcomes of cemented versus cementless posterior-stabilized total knee arthroplasty.Int Orthop2026https://conductscience.org/library/papers/42060141PubMed
42007319Rotational alignment of the native knee joint using magnetic resonance imaging compared to current optimal angles in total knee replacement.J Orthop2026https://conductscience.org/library/papers/42007319PubMed
41909016Comparing Anterior Versus Posterior Size Referencing in Patients Undergoing Simultaneous Bilateral Total Knee Arthroplasty: One Technique Per Knee.Indian J Orthop2026https://conductscience.org/library/papers/41909016PubMed
41749336The transepicondylar axis or the posterior condylar axis: Which is the best reference for femoral component rotation in robotic-assisted total knee arthroplasty?Arthroplasty2026https://conductscience.org/library/papers/41749336PubMed
41669213Rotational Alignment of the Distal Femur Measured Using Magnetic Resonance Image in Korean Population and Its Correlation with X-Ray Measurement.Indian J Orthop2026https://conductscience.org/library/papers/41669213PubMed
41394456Unicompartmental Knee Arthroplasty for the Indian Patient: An Unmet Clinical Need for Redesigning Implants Based on Caucasian Morphometry.Indian J Orthop2025https://conductscience.org/library/papers/41394456PubMed
41019139Osteotomy angle to the femoral neck axis affects the postoperative intact ratio in curved varus osteotomy for osteonecrosis of the femoral head.J Hip Preserv Surg2025https://conductscience.org/library/papers/41019139PubMed
40895679Patellar Instability Following Total Knee Arthroplasty: A Review of Etiology, Diagnosis, and Management Strategies.Cureus2025https://conductscience.org/library/papers/40895679PubMed
40788402The use of navigation to achieve planned coronal alignment during cemented revision total knee arthroplasty: a technical note and case series.Eur J Orthop Surg Traumatol2025https://conductscience.org/library/papers/40788402PubMed
40713594Comparative analysis of femoral component rotational accuracy in robotic-assisted versus navigation-assisted total knee arthroplasty.J Orthop Surg Res2025https://conductscience.org/library/papers/40713594PubMed
40519340Reliability of a modified Berger protocol for TKA component rotation using an anatomical tibial component.J Orthop2025https://conductscience.org/library/papers/40519340PubMed
40515529New Functional Interpretation of the Musculus Popliteus and the Musculus Extensor Digitorum Longus for the Stifle Joint According to Their Origin Coordinates in Dogs.J Morphol2025https://conductscience.org/library/papers/40515529PubMed
40453478
The positive impact of robotic-assisted BCR TKA on post-operative joint line restoration, lateral posterior condylar offset and standard and advanced activity in the 2011 Knee Society Score than the conventional jig-based technique.
J Exp Orthop2025https://conductscience.org/library/papers/40453478PubMed
40394669Knee morphology and patella malalignment in neglected developmental dysplasia of the hip: a systematic review and meta-analysis.J Orthop Surg Res2025https://conductscience.org/library/papers/40394669PubMed
40325159Intraoperative gap assessment in robotic-assisted bicruciate retaining TKA for knee osteoarthritis.Sci Rep2025https://conductscience.org/library/papers/40325159PubMed
40082845Association between femorotibial rotational mismatch and early clinical outcomes after bi-cruciate retaining total knee arthroplasty.BMC Musculoskelet Disord2025https://conductscience.org/library/papers/40082845PubMed
39957918The Role of Computed Tomography in Achieving True External Rotation in Robotic Knee Replacement: A Retrospective Analysis of 300 Knees.J Orthop Case Rep2025https://conductscience.org/library/papers/39957918PubMed
39846233Characteristics of Resection Parameters in Robot-Assisted Total Knee Arthroplasty With the Ligament Balancing Workflow.Orthop Surg2025https://conductscience.org/library/papers/39846233PubMed

See all 243 cited byDownload CSV of cited by

Data dates

The date of each source this release read.

PubMed
2026-11-06
PubMed
iCite
2026-11-05
iCite
PMC's ID file
2026-11-05
PMC's ID file
NIH RePORTER's grant and paper links
2026-11-01
NIH RePORTER's grant and paper links
Trials
2026-11-12
Gene search
2026-11-11
Pipelines
2026-09-18

None in this release

  • Grants
  • Comments and corrections
  • References
  • Genes
  • Drugs
  • Data

Sources 11

  • ChEMBL, through Open TargetsCC BY-SA 3.0
  • ClinicalTrials.govNo license stated
  • HGNCCC0
  • iCiteCC BY 4.0
  • NCBI GenePublic domain (US government)
  • NIH RePORTER's grant and paper linksPublic domain
  • Open TargetsCC0 1.0
  • PMC's ID filePublic domain (US government)
  • PubMedNLM's terms
  • PubTator 3Public domain
  • UniProtCC BY 4.0
Each source's terms
  • ChEMBL, through Open TargetsCC BY-SA 3.0, for the parts from ChEMBL. Read on 8 Nov 2026 at https://platform-docs.opentargets.org/licence
  • ClinicalTrials.govnone stated
  • HGNCCC0: https://www.genenames.org/about/license/
  • iCiteCC BY 4.0
  • NCBI GeneNone named for the file. NCBI says information created by or for the US government on its site is in the public domain, and asks that NLM be acknowledged: https://www.ncbi.nlm.nih.gov/home/about/policies/
  • NIH RePORTER's grant and paper linksPublic domain (NIH RePORTER)
  • Open TargetsCC0 1.0. Open Targets asks that users cite its latest paper: Buniello et al. 2025, Open Targets Platform: facilitating therapeutic hypotheses building in drug discovery, Nucleic Acids Research 53(D1):D1467, PMID 39657122. Read on 8 Nov 2026 at https://platform-docs.opentargets.org/licence
  • PMC's ID fileNone named for the file. NCBI says information created by or for the US government on its site is in the public domain, and asks that NLM be acknowledged: https://www.ncbi.nlm.nih.gov/home/about/policies/
  • PubMedNLM's terms
  • PubTator 3Public domain
  • UniProtCC BY 4.0. UniProt's licence file: "All databases and documents in the UniProt FTP directory may be copied and redistributed freely, without advance permission, provided that this copyright statement is reproduced with each copy." UniProt asks that users cite its latest paper: The UniProt Consortium, UniProt: the Universal Protein Knowledgebase in 2025, Nucleic Acids Research 53:D609-D617, https://doi.org/10.1093/nar/gkae1010. Read on 9 Nov 2026 at https://www.uniprot.org/help/license

ClinicalTrials.gov's data carry an international copyright outside the United States: https://clinicaltrials.gov/about-site/terms-conditions.

For software

Read this paper from software.

The record and each of its lists are JSON, twenty rows a page. No key.

GET https://conductscience.org/api/papers/v1/8425366

GET https://conductscience.org/api/papers/v1/8425366/cited_by?page=2