Trial · NCT01441102

Registered outcomes17

Each outcome the trial registered, primary first, in ClinicalTrials.gov's words.

ListOutcomeTime frameDescription
PrimaryPercentage Change in Retinal Thickness in the Study Eye at 6 Months Compared to BaselineBaseline and 6 months
Retinal thickness was assessed by spectral-domain optical coherence tomography (Cirrus HD-OCT; Carl Zeiss Meditec, Dublin, CA), a non-invasive imaging technique that uses long-wavelength light to capture micrometer-resolution cross-sectional images from biological tissue. The participant's eye that met the study eye eligibility criteria was selected as the study eye. For cases in which both eyes met the study eye eligibility criteria, the study eye was selected according to the "choice of study eye in cases of bilateral disease" selection criteria outlined in the eligibility criteria. The eye not chosen as the study eye is referred to as the "fellow eye."
SecondaryPercentage Change in Retinal Thickness in the Study Eye at 12 Months Compared to BaselineBaseline and 12 Months
Retinal thickness was assessed by spectral-domain optical coherence tomography (Cirrus HD-OCT; Carl Zeiss Meditec, Dublin, CA), a non-invasive imaging technique that uses long-wavelength light to capture micrometer-resolution cross-sectional images from biological tissue. Changes in OCT will be calculated using the ETDRS grid. Attention will be directed to changes in retinal thickness as measured by OCT in each of the 9 subfields of the grid.
SecondaryPercentage Change in Retinal Thickness in the Study Eye at 18 Months Compared to BaselineBaseline and 18 Months
Retinal thickness was assessed by spectral-domain optical coherence tomography (Cirrus HD-OCT; Carl Zeiss Meditec, Dublin, CA), a non-invasive imaging technique that uses long-wavelength light to capture micrometer-resolution cross-sectional images from biological tissue. Changes in OCT will be calculated using the ETDRS grid. Attention will be directed to changes in retinal thickness as measured by OCT in each of the 9 subfields of the grid.
SecondaryPercentage Change in Retinal Thickness in the Study Eye at 24 Months Compared to BaselineBaseline and 24 Months
Retinal thickness was assessed by spectral-domain optical coherence tomography (Cirrus HD-OCT; Carl Zeiss Meditec, Dublin, CA), a non-invasive imaging technique that uses long-wavelength light to capture micrometer-resolution cross-sectional images from biological tissue. Changes in OCT will be calculated using the ETDRS grid. Attention will be directed to changes in retinal thickness as measured by OCT in each of the 9 subfields of the grid.
SecondaryChange in Best-corrected Visual Acuity (BCVA) in the Study Eye at 6 Months Compared to BaselineBaseline and 6 Months
Visual acuity was measured using the Early Treatment Diabetic Retinopathy Study (ETDRS) protocol. Acuity is measured as letters read on an ETDRS eye chart and the letters read equate to Snellen measurements. For example, if a participant reads between 84 and 88 letters, the equivalent Snellen measurement is 20/20.
SecondaryChange in Best-corrected Visual Acuity (BCVA) in the Study Eye at 12 Months Compared to BaselineBaseline and 12 Months
Visual acuity was measured using the Early Treatment Diabetic Retinopathy Study (ETDRS) protocol. Acuity is measured as letters read on an ETDRS eye chart and the letters read equate to Snellen measurements. For example, if a participant reads between 84 and 88 letters, the equivalent Snellen measurement is 20/20.
SecondaryChange in Best-corrected Visual Acuity (BCVA) in the Study Eye at 18 Months Compared to BaselineBaseline and 18 Months
Visual acuity was measured using the Early Treatment Diabetic Retinopathy Study (ETDRS) protocol. Acuity is measured as letters read on an ETDRS eye chart and the letters read equate to Snellen measurements. For example, if a participant reads between 84 and 88 letters, the equivalent Snellen measurement is 20/20.
SecondaryChange in Best-corrected Visual Acuity (BCVA) in the Study Eye at 24 Months Compared to BaselineBaseline and 24 Months
Visual acuity was measured using the Early Treatment Diabetic Retinopathy Study (ETDRS) protocol. Acuity is measured as letters read on an ETDRS eye chart and the letters read equate to Snellen measurements. For example, if a participant reads between 84 and 88 letters, the equivalent Snellen measurement is 20/20.
SecondaryNumber of Study Eyes Demonstrating a Decrease in the Area of Late Leakage, as Measured by Fluorescein Angiography (FA), at 6 Months Compared to BaselineBaseline and 6 Months
Fluorescein angiography (FA) images were obtained via a standard digital imaging system (OIS, Sacramento, CA) at baseline and at Month 6, Month 12, Month 18, and Month 24. Three retinal specialists independently graded the area of late fluorescein leakage (at approximately 10 minutes) using a region-of-interest tool in an image analysis software package (NIH ImageJ, Bethesda, MD).
SecondaryNumber of Study Eyes Demonstrating a Decrease in the Area of Late Leakage, as Measured by Fluorescein Angiography (FA), at 12 Months Compared to BaselineBaseline and 12 Months
Fluorescein angiography (FA) images were obtained via a standard digital imaging system (OIS, Sacramento, CA) at baseline and at Month 6, Month 12, Month 18, and Month 24. Three retinal specialists independently graded the area of late fluorescein leakage (at approximately 10 minutes) using a region-of-interest tool in an image analysis software package (NIH ImageJ, Bethesda, MD).
SecondaryNumber of Study Eyes Demonstrating a Decrease in the Area of Late Leakage, as Measured by Fluorescein Angiography (FA), at 18 Months Compared to BaselineBaseline and 18 Months
Fluorescein angiography (FA) images were obtained via a standard digital imaging system (OIS, Sacramento, CA) at baseline and at Month 6, Month 12, Month 18, and Month 24. Three retinal specialists independently graded the area of late fluorescein leakage (at approximately 10 minutes) using a region-of-interest tool in an image analysis software package (NIH ImageJ, Bethesda, MD).
SecondaryNumber of Study Eyes Demonstrating a Decrease in the Area of Late Leakage, as Measured by Fluorescein Angiography (FA), at 24 Months Compared to BaselineBaseline and 24 Months
Fluorescein angiography (FA) images were obtained via a standard digital imaging system (OIS, Sacramento, CA) at baseline and at Month 6, Month 12, Month 18, and Month 24. Three retinal specialists independently graded the area of late fluorescein leakage (at approximately 10 minutes) using a region-of-interest tool in an image analysis software package (NIH ImageJ, Bethesda, MD).
SecondaryChanges in Mean Macular Sensitivity in the Study Eye at 6 Months Compared to BaselineBaseline and 6 MonthsMicroperimetry was used to assess macular sensitivity.
SecondaryChanges in Mean Macular Sensitivity in the Study Eye at 12 Months Compared to BaselineBaseline and 12 MonthsMicroperimetry was used to assess macular sensitivity.
SecondaryChanges in Mean Macular Sensitivity in the Study Eye at 18 Months Compared to BaselineBaseline and 18 MonthsMicroperimetry was used to assess macular sensitivity.
SecondaryChanges in Mean Macular Sensitivity in the Study Eye at 24 Months Compared to BaselineBaseline and 24 MonthsMicroperimetry was used to assess macular sensitivity.
SecondaryNumber of Participants Withdrawn From the Study Therapy Due to Vision Loss or Adverse EventsDuration of the study, up to 24 months

Source ClinicalTrials.govtrials-2026-11-12-0.5.0

Sources 3

  • ClinicalTrials.gov's posted results, through CTTI's AACTFreely available. Acknowledgement requested
  • ClinicalTrials.govNo license stated
  • NIH RePORTER's clinical studies and project filesPublic domain
Each source's terms
  • ClinicalTrials.gov's posted results, through CTTI's AACTClinicalTrials.gov data via Aggregate Analysis of ClinicalTrials.gov (AACT), CTTI. CTTI makes its materials freely available and requests acknowledgement. https://aact.ctti-clinicaltrials.org/documentation/299
  • ClinicalTrials.govnone stated
  • NIH RePORTER's clinical studies and project filesPublic domain (NIH RePORTER)