Registered outcomes19

Each outcome the trial registered, primary first, in ClinicalTrials.gov's words.

ListOutcomeTime frameDescription
PrimaryPulmonary perfusion was assessed using both pulse wave and saline bolus EIT at PEEP levels of 5 and 15 cmH₂O.Under both PEEP 5 cmH₂O and PEEP 15 cmH₂O conditions, EIT data were acquired after 30 minutes of stable ventilation.
At a PEEP of 5 cmH₂O, pulse wave EIT data were recorded for 3 minutes. Subsequently, during an inspiratory or expiratory hold, a 10 mL bolus of 10% hypertonic saline was administered via the central venous catheter while EIT data were simultaneously recorded for another 3 minutes. This procedure was repeated at a PEEP of 15 cmH₂O. Pulmonary perfusion data were obtained through offline analysis of the EIT data.
SecondaryAt PEEP 5 cmH₂O and 15 cmH₂O, perform EIT monitoring of pulmonary perfusion during a 15-second inspiratory or expiratory hold.Under both PEEP 5 cmH₂O and PEEP 15 cmH₂O conditions, EIT data were acquired after 30 minutes of stable ventilation.
At a PEEP of 5 cmH₂O, EIT data were first recorded for 1 minute, followed by a 15-second inspiratory hold, after which data acquisition was continued for an additional 2 minutes. The entire procedure was repeated at a PEEP of 15 cmH₂O. Pulmonary perfusion data were subsequently analyzed using offline software.
SecondaryUnder PEEP 5 cmH₂O conditions, EIT data were acquired during bolus injections of either 10 mL of 0.9% saline or 10 mL of 10% hypertonic saline for pulmonary perfusion analysis.Under a PEEP of 5 cmH₂O, EIT data acquisition was performed after 30 minutes of stable ventilation.
At a PEEP of 5 cmH₂O, the following protocol was performed: First, EIT data were recorded for 1 minute, followed by a bolus injection of 10 mL of 0.9% saline via the central venous catheter; data acquisition then continued for an additional 2 minutes. Then, the procedure was repeated with a bolus injection of 10 mL of 10% hypertonic saline. Pulmonary perfusion data were subsequently analyzed using offline software.
SecondaryThe ventilation-perfusion matching percentage was assessed using both pulse wave and saline bolus EIT at PEEP levels of 5 and 15 cmH₂O.Under both PEEP 5 cmH₂O and PEEP 15 cmH₂O conditions, EIT data were acquired after 30 minutes of stable ventilation.The ventilation-perfusion matching percentage was derived from EIT images using offline analysis software.
SecondaryThe ventilation-perfusion matching percentage was monitored by EIT during 15-second inspiratory or expiratory holds at PEEP levels of 5 and 15 cmH₂O.Under both PEEP 5 cmH₂O and PEEP 15 cmH₂O conditions, EIT data were acquired after 30 minutes of stable ventilation.The ventilation-perfusion matching percentage was derived from EIT images using offline analysis software.
SecondaryUnder PEEP 5 cmH₂O conditions, EIT data were acquired during bolus injections of either 10 mL of 0.9% saline or 10 mL of 10% hypertonic saline for ventilation-perfusion matching percentage.Under a PEEP of 5 cmH₂O, EIT data acquisition was performed after 30 minutes of stable ventilation.The ventilation-perfusion matching percentage was derived from EIT images using offline analysis software.
SecondaryThe dead space percentage was assessed using both pulse wave and saline bolus EIT at PEEP levels of 5 and 15 cmH₂O.Under both PEEP 5 cmH₂O and PEEP 15 cmH₂O conditions, EIT data were acquired after 30 minutes of stable ventilation.The ventilation-perfusion matching percentage was derived from EIT images using offline analysis software.
SecondaryThe dead space percentage was monitored by EIT during 15-second inspiratory or expiratory holds at PEEP levels of 5 and 15 cmH₂O.Under both PEEP 5 cmH₂O and PEEP 15 cmH₂O conditions, EIT data were acquired after 30 minutes of stable ventilation.The ventilation-perfusion matching percentage was derived from EIT images using offline analysis software.
SecondaryUnder PEEP 5 cmH₂O conditions, the dead space percentage was obtained by EIT monitoring following bolus injections of either 10 mL of 0.9% saline or 10 mL of 10% hypertonic saline.Under PEEP 5 cmH₂O conditions, EIT data were acquired after 30 minutes of stable ventilation.The ventilation-perfusion matching percentage was derived from EIT images using offline analysis software.
SecondaryThe shunt percentage was assessed using both pulse wave and saline bolus EIT at PEEP levels of 5 and 15 cmH₂O.Under both PEEP 5 cmH₂O and PEEP 15 cmH₂O conditions, EIT data were acquired after 30 minutes of stable ventilation.The ventilation-perfusion matching percentage was derived from EIT images using offline analysis software.
SecondaryThe shunt space percentage was monitored by EIT during 15-second inspiratory or expiratory holds at PEEP levels of 5 and 15 cmH₂O.Under both PEEP 5 cmH₂O and PEEP 15 cmH₂O conditions, EIT data were acquired after 30 minutes of stable ventilation.The ventilation-perfusion matching percentage was derived from EIT images using offline analysis software.
SecondaryUnder PEEP 5 cmH₂O conditions, the shunt space percentage was obtained by EIT monitoring following bolus injections of either 10 mL of 0.9% saline or 10 mL of 10% hypertonic saline.Under PEEP 5 cmH₂O conditions, EIT data were acquired after 30 minutes of stable ventilation.The ventilation-perfusion matching percentage was derived from EIT images using offline analysis software.
Secondary
At PEEP 5 cmH₂O, heart rate was monitored: at baseline, during 15-second inspiratory and expiratory holds, following bolus injections of 10 mL of 0.9% saline and 10% hypertonic saline, and during combined breath-hold-and-injection procedures.
Under PEEP 5 cmH₂O conditions, EIT data were acquired after 30 minutes of stable ventilation.Heart rate was obtained from the patient monitor.
SecondaryAt PEEP 15 cmH₂O, heart rate was monitored: at baseline, during 15-second inspiratory and expiratory holds, and during combined breath-hold-and-injection procedures.Under PEEP 15 cmH₂O conditions, EIT data were acquired after 30 minutes of stable ventilation.Heart rate was obtained from the patient monitor.
Secondary
At PEEP 5 cmH₂O, blood pressure was monitored: at baseline, during 15-second inspiratory and expiratory holds, following bolus injections of 10 mL of 0.9% saline and 10% hypertonic saline, and during combined breath-hold-and-injection procedures.
Under PEEP 5 cmH₂O conditions, EIT data were acquired after 30 minutes of stable ventilation.Blood pressure was obtained from the patient monitor.
SecondaryAt PEEP 15 cmH₂O, blood pressure was monitored: at baseline, during 15-second inspiratory and expiratory holds, and during combined breath-hold-and-injection procedures.Under PEEP 15 cmH₂O conditions, EIT data were acquired after 30 minutes of stable ventilation.Blood pressure was obtained from the patient monitor.
Secondary
At PEEP 5 cmH₂O, central venous pressure was monitored: at baseline, during 15-second inspiratory and expiratory holds, following bolus injections of 10 mL of 0.9% saline and 10% hypertonic saline, and during combined breath-hold-and-injection procedures
Under PEEP 5 cmH₂O conditions, EIT data were acquired after 30 minutes of stable ventilation.Central venous pressure was obtained from the patient monitor.
SecondaryAt PEEP 15 cmH₂O, central venous pressure was monitored: at baseline, during 15-second inspiratory and expiratory holds, and during combined breath-hold-and-injection procedures.Under PEEP 15 cmH₂O conditions, EIT data were acquired after 30 minutes of stable ventilation.Central venous pressure was obtained from the patient monitor.
SecondaryThe PaO₂/FiO₂ ratio was recorded prior to patient enrollment.Prior to enrollmentThe PaO₂/FiO₂ ratio was obtained from arterial blood gas analysis.

Source ClinicalTrials.govtrials-2026-11-12-0.5.0

Sources 3

  • ClinicalTrials.gov's posted results, through CTTI's AACTFreely available. Acknowledgement requested
  • ClinicalTrials.govNo license stated
  • NIH RePORTER's clinical studies and project filesPublic domain
Each source's terms
  • ClinicalTrials.gov's posted results, through CTTI's AACTClinicalTrials.gov data via Aggregate Analysis of ClinicalTrials.gov (AACT), CTTI. CTTI makes its materials freely available and requests acknowledgement. https://aact.ctti-clinicaltrials.org/documentation/299
  • ClinicalTrials.govnone stated
  • NIH RePORTER's clinical studies and project filesPublic domain (NIH RePORTER)

ClinicalTrials.gov's data carry an international copyright outside the United States: https://clinicaltrials.gov/about-site/terms-conditions.

For software

Read this list from software.

Twenty rows a page, as JSON. No key.

GET https://conductscience.org/api/trials/v1/NCT07908368/registered