ConductScience.org, home

Paper28293707

Image quality and radiation dose of brain computed tomography in children: effects of decreasing tube voltage from 120 kVp to 80 kVp.

Park JE and 7 others. Pediatr Radiol, 2017. Cited by 28 papers, by iCite.

Cite this record

ConductScience Library. Image quality and radiation dose of brain computed tomography in children: effects of decreasing tube voltage from 120 kVp to 80 kVp. Papers, record 28293707. Release papers-2026-11-12-0.1.0, 12 Nov 2026. https://conductscience.org/library/papers/28293707

Sign in to download
Sources
11 sources
Release
papers-2026-11-12-0.1.0

Paper

PubMed's record of the paper, with iCite's citation figures. No abstract is shown.

Title
Image quality and radiation dose of brain computed tomography in children: effects of decreasing tube voltage from 120 kVp to 80 kVp.
PubMed
Journal
Pediatr Radiol
PubMed
Year
2017
PubMed
Publication types
Journal Article
PubMed
Citations, by iCite
28
iCite
Relative citation ratio, by iCite
1.95
iCite
Revised in PubMed
2018-11-13
PubMed

Authors8

The authors in the order PubMed's record lists them, with the ORCID iDs it states.

OrderAuthorForenameKindORCID iD
1Park JEJi Eun
2Choi YHYoung Hunhttps://orcid.org/0000-0002-1842-9062
3Cheon JEJung-Eun
4Kim WSWoo Sun
5Kim IOIn-One
6Cho HSHyun Suk
7Ryu YJYoung Jin
8Kim YJYu Jin

Source PubMed

Sign in to download

Topics13

NLM's MeSH indexing of the paper, its major topics first.

MeSH termMajor
BrainMajor topic
Brain DiseasesMajor topic
Radiation DosageMajor topic
Radiation ProtectionMajor topic
Tomography, X-Ray ComputedMajor topic
Adolescent
Child
Child, Preschool
Female
Humans
Infant
Male
Signal-To-Noise Ratio

Source PubMed

Sign in to download

References17

The papers the reference list in PubMed's record names, those in our copy of PubMed, in the list's order.

OrderPMIDTitleJournalYearIn PapersSource
119864524National Council on Radiation Protection and Measurements report shows substantial medical exposure increase.Radiology2009https://conductscience.org/library/papers/19864524PubMed
224768150Significance of enhanced cerebral gray-white matter contrast at 80 kVp compared to conventional 120 kVp CT scan in the evaluation of acute stroke.J Clin Neurosci2014https://conductscience.org/library/papers/24768150PubMed
36771308Explanation of cerebral white--gray contrast in computed tomography.J Comput Assist Tomogr1980https://conductscience.org/library/papers/6771308PubMed
418046031Computed tomography--an increasing source of radiation exposure.N Engl J Med2007https://conductscience.org/library/papers/18046031PubMed
522300930Low kilovoltage CT of the neck with 70 kVp: comparison with a standard protocol.AJNR Am J Neuroradiol2012https://conductscience.org/library/papers/22300930PubMed
69114097An approach for the estimation of effective radiation dose at CT in pediatric patients.Radiology1997https://conductscience.org/library/papers/9114097PubMed
718397968Low-dose nonenhanced head CT protocol for follow-up evaluation of children with ventriculoperitoneal shunt: reduction of radiation and effect on image quality.AJNR Am J Neuroradiol2008https://conductscience.org/library/papers/18397968PubMed
8967922Energy-selective reconstructions in X-ray computerized tomography.Phys Med Biol1976https://conductscience.org/library/papers/967922PubMed
92026796Cranial CT artifacts and gantry angulation.J Comput Assist Tomogr1991https://conductscience.org/library/papers/2026796PubMed
1012244457Lessons we have learned from our children: cancer risks from diagnostic radiology.Pediatr Radiol2002https://conductscience.org/library/papers/12244457PubMed
1120851940Multisection CT protocols: sex- and age-specific conversion factors used to determine effective dose from dose-length product.Radiology2010https://conductscience.org/library/papers/20851940PubMed
1219195532Strategies for reducing radiation dose in CT.Radiol Clin North Am2009https://conductscience.org/library/papers/19195532PubMed
1315090337Comparison of image quality between conventional and low-dose nonenhanced head CT.AJNR Am J Neuroradiol2004https://conductscience.org/library/papers/15090337PubMed
1421571660Optimal tube potential for radiation dose reduction in pediatric CT: principles, clinical implementations, and pitfalls.Radiographics2011https://conductscience.org/library/papers/21571660PubMed
1523883244Automatic selection of tube potential for radiation dose reduction in vascular and contrast-enhanced abdominopelvic CT.AJR Am J Roentgenol2013https://conductscience.org/library/papers/23883244PubMed
1617467387Dose reduction in paediatric MDCT: general principles.Clin Radiol2007https://conductscience.org/library/papers/17467387PubMed
1723074259Virtual monochromatic reconstruction of dual-energy unenhanced head CT at 65-75 keV maximizes image quality compared with conventional polychromatic CT.Radiology2013https://conductscience.org/library/papers/23074259PubMed

Sign in to download

Cited by17

The papers in our copy of PubMed whose reference list names this one, newest first. iCite, which reads more sources, counts 28 citations.

PMIDTitleJournalYearIn PapersSource
42185396Development of a model for design radiation shielding composite aprons using machine learning.Sci Rep2026https://conductscience.org/library/papers/42185396PubMed
42057836Study of displayed radiation dose and size-specific dose estimate from computed tomography brain examinations in accordance to head sizes.World J Radiol2026https://conductscience.org/library/papers/42057836PubMed
41973105Feasibility of electron density map derived from unenhanced dual-energy CT for detecting peritonsillar abscess.Neuroradiology2026https://conductscience.org/library/papers/41973105PubMed
41567817Advancements in radiation dose reduction for pediatric CT head Imaging: A scoping review of emerging Technologies, Protocols, and optimization strategies.Tech Innov Patient Support Radiat Oncol2026https://conductscience.org/library/papers/41567817PubMed
41144121Image Quality Optimization in 60 kVp Head-Neck CTA: A Comparative Study of FBP, ClearView, and ClearInfinity Reconstruction Algorithms.Curr Med Sci2025https://conductscience.org/library/papers/41144121PubMed
41006436Radiation dose optimisation in paediatric head CT using attenuation-based auto prescription.Sci Rep2025https://conductscience.org/library/papers/41006436PubMed
39037987Optimal image quality and radiation doses with optimal tube voltages/currents for pediatric anthropomorphic phantom brains.PLoS One2024https://conductscience.org/library/papers/39037987PubMed
38015280Low Dose Pediatric CT Head Protocol using Iterative Reconstruction Techniques: A Comparison with Standard Dose Protocol.Clin Neuroradiol2024https://conductscience.org/library/papers/38015280PubMed
37735089Dual-Layer Detector Head CT to Maintain Image Quality While Reducing the Radiation Dose in Pediatric Patients.AJNR Am J Neuroradiol2023https://conductscience.org/library/papers/37735089PubMed
37622039Tradeoffs between Radiation Exposure to the Lens of the Eyes and Diagnostic Image Quality in Pediatric Brain Computed Tomography.J Med Signals Sens2023https://conductscience.org/library/papers/37622039PubMed
37488451Ultra-low-dose computed tomography with deep learning reconstruction for craniosynostosis at radiation doses comparable to skull radiographs: a pilot study.Pediatr Radiol2023https://conductscience.org/library/papers/37488451PubMed
36287806Sample Size and Estimation of Standard Radiation Doses for Pediatric Brain CT.Tomography2022https://conductscience.org/library/papers/36287806PubMed
35448713Radiation Dose Management in Pediatric Brain CT According to Age and Weight as Continuous Variables.Tomography2022https://conductscience.org/library/papers/35448713PubMed
33569932Virtual Monochromatic Image Quality from Dual-Layer Dual-Energy Computed Tomography for Detecting Brain Tumors.Korean J Radiol2021https://conductscience.org/library/papers/33569932PubMed
32823818Diagnostic Reference Level of Radiation Dose and Image Quality among Paediatric CT Examinations in A Tertiary Hospital in Malaysia.Diagnostics (Basel)2020https://conductscience.org/library/papers/32823818PubMed
32728777Virtual monochromatic dual-energy CT reconstructions improve detection of cerebral infarct in patients with suspicion of stroke.Neuroradiology2021https://conductscience.org/library/papers/32728777PubMed
28656326
Advanced virtual monochromatic reconstruction of dual-energy unenhanced brain computed tomography in children: comparison of image quality against standard mono-energetic images and conventional polychromatic computed tomography.
Pediatr Radiol2017https://conductscience.org/library/papers/28656326PubMed

Sign in to download

Data dates

The date of each source this release read.

PubMed
2026-11-06
PubMed
iCite
2026-11-05
iCite
PMC's ID file
2026-11-05
PMC's ID file
NIH RePORTER's grant and paper links
2026-11-01
NIH RePORTER's grant and paper links
Trials
2026-11-12
Gene search
2026-11-11
Pipelines
2026-09-18

None in this release

  • Grants
  • Trials
  • Comments and corrections
  • Genes
  • Drugs
  • Data

Sources 11

  • ChEMBL, through Open TargetsCC BY-SA 3.0
  • ClinicalTrials.govNo license stated
  • HGNCCC0
  • iCiteCC BY 4.0
  • NCBI GenePublic domain (US government)
  • NIH RePORTER's grant and paper linksPublic domain
  • Open TargetsCC0 1.0
  • PMC's ID filePublic domain (US government)
  • PubMedNLM's terms
  • PubTator 3Public domain
  • UniProtCC BY 4.0
Each source's terms
  • ChEMBL, through Open TargetsCC BY-SA 3.0, for the parts from ChEMBL. Read on 8 Nov 2026 at https://platform-docs.opentargets.org/licence
  • ClinicalTrials.govnone stated
  • HGNCCC0: https://www.genenames.org/about/license/
  • iCiteCC BY 4.0
  • NCBI GeneNone named for the file. NCBI says information created by or for the US government on its site is in the public domain, and asks that NLM be acknowledged: https://www.ncbi.nlm.nih.gov/home/about/policies/
  • NIH RePORTER's grant and paper linksPublic domain (NIH RePORTER)
  • Open TargetsCC0 1.0. Open Targets asks that users cite its latest paper: Buniello et al. 2025, Open Targets Platform: facilitating therapeutic hypotheses building in drug discovery, Nucleic Acids Research 53(D1):D1467, PMID 39657122. Read on 8 Nov 2026 at https://platform-docs.opentargets.org/licence
  • PMC's ID fileNone named for the file. NCBI says information created by or for the US government on its site is in the public domain, and asks that NLM be acknowledged: https://www.ncbi.nlm.nih.gov/home/about/policies/
  • PubMedNLM's terms
  • PubTator 3Public domain
  • UniProtCC BY 4.0. UniProt's licence file: "All databases and documents in the UniProt FTP directory may be copied and redistributed freely, without advance permission, provided that this copyright statement is reproduced with each copy." UniProt asks that users cite its latest paper: The UniProt Consortium, UniProt: the Universal Protein Knowledgebase in 2025, Nucleic Acids Research 53:D609-D617, https://doi.org/10.1093/nar/gkae1010. Read on 9 Nov 2026 at https://www.uniprot.org/help/license

ClinicalTrials.gov's data carry an international copyright outside the United States: https://clinicaltrials.gov/about-site/terms-conditions.

For software

Read this paper from software.

The record and each of its lists are JSON, twenty rows a page. No key needed for records and first pages, up to 100 calls a day. With a free key, your account gets 2,000 a day and every page.

GET https://conductscience.org/api/papers/v1/28293707

GET https://conductscience.org/api/papers/v1/28293707/authors