Paper41144121
Image Quality Optimization in 60 kVp Head-Neck CTA: A Comparative Study of FBP, ClearView, and ClearInfinity Reconstruction Algorithms.
Wang SF and 8 others. Curr Med Sci, 2025. Cited by 3 papers, by iCite.
Cite this record
ConductScience Library. Image Quality Optimization in 60 kVp Head-Neck CTA: A Comparative Study of FBP, ClearView, and ClearInfinity Reconstruction Algorithms. Papers, record 41144121. Release papers-2026-11-12-0.1.0, 12 Nov 2026. https://conductscience.org/library/papers/41144121
- Sources
- 11 sources
- Release
- papers-2026-11-12-0.1.0
Paper
PubMed's record of the paper, with iCite's citation figures. No abstract is shown.
- Title
- Image Quality Optimization in 60 kVp Head-Neck CTA: A Comparative Study of FBP, ClearView, and ClearInfinity Reconstruction Algorithms.
- PubMed
Topics13
NLM's MeSH indexing of the paper, its major topics first.
| MeSH term | Major |
|---|---|
| Algorithms | Major topic |
| Computed Tomography Angiography | Major topic |
| Head | Major topic |
| Neck | Major topic |
| Image Processing, Computer-Assisted | Major topic |
| Radiographic Image Interpretation, Computer-Assisted | Major topic |
| Humans | |
| Male | |
| Female | |
| Middle Aged | |
| Aged | |
| Prospective Studies | |
| Adult |
Source PubMed
Grants4
Each grant PubMed's record writes, matched to the NIH project NIH's grant and paper links name for this paper, and each of those links the record does not write.
| Grant, as the record writes it | Agency | Country | NIH project | Stated by |
|---|---|---|---|---|
| 2024YFC2419300 | National Key Research and Development Program of China | PubMed | ||
| 82471967 | National Natural Science Foundation of China | PubMed | ||
| 2024BCB008 | Hubei Provincial Key Research and Development Program | PubMed | ||
| 2025AFB733 | Natural Science Foundation of Hubei Province | PubMed |
Source PubMed
References26
The papers the reference list in PubMed's record names, those in our copy of PubMed, in the list's order.
| Order | PMID | Title | Journal | Year | In Papers | Source |
|---|---|---|---|---|---|---|
| 1 | 30397728 | Image Quality of CT Angiography of Supra-Aortic Arteries : Comparison Between Advanced Modelled Iterative Reconstruction (ADMIRE), Sinogram Affirmed Iterative Reconstruction (SAFIRE) and Filtered Back Projection (FBP) in One Patients' Group. | Clin Neuroradiol | 2020 | https://conductscience.org/library/papers/30397728 | PubMed |
| 2 | 32166681 | Application of Low Tube Voltage, Low-concentration Contrast Agent Using a 320-row CT in Coronary CT Angiography: Evaluation of Image Quality, Radiation Dose and Iodine Intake. | Curr Med Sci | 2020 | https://conductscience.org/library/papers/32166681 | PubMed |
| 3 | 30691665 | Low-tube-voltage CT assessment of Adamkiewicz artery: Precise comparison between 100-kVp- and 120-kVp protocols. | Eur J Radiol | 2019 | https://conductscience.org/library/papers/30691665 | PubMed |
| 4 | 31031186 | Reducing Radiation Dose and Improving Image Quality in CT Portal Venography Using 80 kV and Adaptive Statistical Iterative Reconstruction-V in Slender Patients. | Acad Radiol | 2020 | https://conductscience.org/library/papers/31031186 | PubMed |
| 5 | 34597178 | Deep Learning-based Reconstruction for Lower-Dose Pediatric CT: Technical Principles, Image Characteristics, and Clinical Implementations. | Radiographics | 2021 | https://conductscience.org/library/papers/34597178 | PubMed |
| 6 | 28293707 | Image quality and radiation dose of brain computed tomography in children: effects of decreasing tube voltage from 120 kVp to 80 kVp. | Pediatr Radiol | 2017 | https://conductscience.org/library/papers/28293707 | PubMed |
| 7 | 31039013 | Low-Dose CT With the Adaptive Statistical Iterative Reconstruction V Technique in Abdominal Organ Injury: Comparison With Routine-Dose CT With Filtered Back Projection. | AJR Am J Roentgenol | 2019 | https://conductscience.org/library/papers/31039013 | PubMed |
| 8 | 39542806 | Feasibility of Ultra-low Radiation and Contrast Medium Dosage in Aortic CTA Using Deep Learning Reconstruction at 60 kVp: An Image Quality Assessment. | Acad Radiol | 2025 | https://conductscience.org/library/papers/39542806 | PubMed |
| 9 | 35596780 | The impact of deep learning reconstruction on image quality and coronary CT angiography-derived fractional flow reserve values. | Eur Radiol | 2022 | https://conductscience.org/library/papers/35596780 | PubMed |
| 10 | 33302311 | Deep Learning CT Image Reconstruction in Clinical Practice. | Rofo | 2021 | https://conductscience.org/library/papers/33302311 | PubMed |
| 11 | 40126762 | Artificial intelligence and its potential integration with the clinical practice of diagnostic imaging medical physicists: a review. | Phys Eng Sci Med | 2025 | https://conductscience.org/library/papers/40126762 | PubMed |
| 12 | 27250976 | Diagnostic performance of CT angiography in neck vessel trauma: systematic review and meta-analysis. | Emerg Radiol | 2016 | https://conductscience.org/library/papers/27250976 | PubMed |
| 13 | 40785866 | Ultra-low-dose hepatic computed tomography with a novel real-time deep learning-based noise reduction algorithm: a prospective cross-sectional analysis of image quality and lesion detection. | Quant Imaging Med Surg | 2025 | https://conductscience.org/library/papers/40785866 | PubMed |
| 14 | 34144309 | Effect of deep learning image reconstruction in the prediction of resectability of pancreatic cancer: Diagnostic performance and reader confidence. | Eur J Radiol | 2021 | https://conductscience.org/library/papers/34144309 | PubMed |
| 15 | 34585611 | Head and Neck CTA Utilization: Analysis of Ordering Frequency and Nonroutine Results Communication, With Focus on the 50 Most Common Emergency Department Clinical Presentations. | AJR Am J Roentgenol | 2022 | https://conductscience.org/library/papers/34585611 | PubMed |
| 16 | 36071138 | Deep learning-based reconstruction on cardiac CT yields distinct radiomic features compared to iterative and filtered back projection reconstructions. | Sci Rep | 2022 | https://conductscience.org/library/papers/36071138 | PubMed |
| 17 | 40243988 | Routine CT Diagnostics Cause Dose-Dependent Gene Expression Changes in Peripheral Blood Cells. | Int J Mol Sci | 2025 | https://conductscience.org/library/papers/40243988 | PubMed |
| 18 | 40140592 | Multimodal generative AI for medical image interpretation. | Nature | 2025 | https://conductscience.org/library/papers/40140592 | PubMed |
| 19 | 36197579 | Deep learning image reconstruction algorithm reduces image noise while alters radiomics features in dual-energy CT in comparison with conventional iterative reconstruction algorithms: a phantom study. | Eur Radiol | 2023 | https://conductscience.org/library/papers/36197579 | PubMed |
| 20 | 37946058 | Risk of hematological malignancies from CT radiation exposure in children, adolescents and young adults. | Nat Med | 2023 | https://conductscience.org/library/papers/37946058 | PubMed |
Cited by2
The papers in our copy of PubMed whose reference list names this one, newest first. iCite, which reads more sources, counts 3 citations.
| PMID | Title | Journal | Year | In Papers | Source |
|---|---|---|---|---|---|
| 42147944 | Evaluation of optimal ClearInfinity artificial intelligence deep learning reconstruction algorithm weights with a 70-kVp tube voltage combined with "dual-low" abdominal computed tomography angiography. | Quant Imaging Med Surg | 2026 | https://conductscience.org/library/papers/42147944 | PubMed |
| 41940980 | Deep learning reconstruction for 40-keV virtual monoenergetic CT of colon cancer: evaluation of image quality and edge sharpness. | Abdom Radiol (NY) | 2026 | https://conductscience.org/library/papers/41940980 | PubMed |
Data dates
The date of each source this release read.
- Trials
- 2026-11-12
- Gene search
- 2026-11-11
- Pipelines
- 2026-09-18
None in this release
- Trials
- Comments and corrections
- Genes
- Drugs
- Data
Sources 11
- ChEMBL, through Open TargetsCC BY-SA 3.0
- ClinicalTrials.govNo license stated
- HGNCCC0
- iCiteCC BY 4.0
- NCBI GenePublic domain (US government)
- NIH RePORTER's grant and paper linksPublic domain
- Open TargetsCC0 1.0
- PMC's ID filePublic domain (US government)
- PubMedNLM's terms
- PubTator 3Public domain
- UniProtCC BY 4.0
Each source's terms
- ChEMBL, through Open TargetsCC BY-SA 3.0, for the parts from ChEMBL. Read on 8 Nov 2026 at https://platform-docs.opentargets.org/licence
- ClinicalTrials.govnone stated
- HGNCCC0: https://www.genenames.org/about/license/
- iCiteCC BY 4.0
- NCBI GeneNone named for the file. NCBI says information created by or for the US government on its site is in the public domain, and asks that NLM be acknowledged: https://www.ncbi.nlm.nih.gov/home/about/policies/
- NIH RePORTER's grant and paper linksPublic domain (NIH RePORTER)
- Open TargetsCC0 1.0. Open Targets asks that users cite its latest paper: Buniello et al. 2025, Open Targets Platform: facilitating therapeutic hypotheses building in drug discovery, Nucleic Acids Research 53(D1):D1467, PMID 39657122. Read on 8 Nov 2026 at https://platform-docs.opentargets.org/licence
- PMC's ID fileNone named for the file. NCBI says information created by or for the US government on its site is in the public domain, and asks that NLM be acknowledged: https://www.ncbi.nlm.nih.gov/home/about/policies/
- PubMedNLM's terms
- PubTator 3Public domain
- UniProtCC BY 4.0. UniProt's licence file: "All databases and documents in the UniProt FTP directory may be copied and redistributed freely, without advance permission, provided that this copyright statement is reproduced with each copy." UniProt asks that users cite its latest paper: The UniProt Consortium, UniProt: the Universal Protein Knowledgebase in 2025, Nucleic Acids Research 53:D609-D617, https://doi.org/10.1093/nar/gkae1010. Read on 9 Nov 2026 at https://www.uniprot.org/help/license
ClinicalTrials.gov's data carry an international copyright outside the United States: https://clinicaltrials.gov/about-site/terms-conditions.
For software
Read this paper from software.
The record and each of its lists are JSON, twenty rows a page. No key needed for records and first pages, up to 100 calls a day. With a free key, your account gets 2,000 a day and every page.
GET https://conductscience.org/api/papers/v1/41144121
GET https://conductscience.org/api/papers/v1/41144121/references?page=2