Paper35909705
Suction thrombectomy using a microcatheter as a salvage method for acute distal occlusion during cerebral aneurysm embolization: A case report.
Drakopoulou M and 6 others. Brain Circ, 2022. Cited by 2 papers, by iCite.
Cite this record
ConductScience Library. Suction thrombectomy using a microcatheter as a salvage method for acute distal occlusion during cerebral aneurysm embolization: A case report. Papers, record 35909705. Release papers-2026-11-12-0.1.0, 12 Nov 2026. https://conductscience.org/library/papers/35909705
- Sources
- 11 sources
- Release
- papers-2026-11-12-0.1.0
Paper
PubMed's record of the paper, with iCite's citation figures. No abstract is shown.
- Title
- Suction thrombectomy using a microcatheter as a salvage method for acute distal occlusion during cerebral aneurysm embolization: A case report.
- PubMed
Topics0
NLM's MeSH indexing of the paper, its major topics first.
None in this release.
References23
The papers the reference list in PubMed's record names, those in our copy of PubMed, in the list's order.
| Order | PMID | Title | Journal | Year | In Papers | Source |
|---|---|---|---|---|---|---|
| 1 | 28271328 | Intraprocedural Thrombus Fragmentation During Interventional Stroke Treatment: A Comparison of Direct Thrombus Aspiration and Stent Retriever Thrombectomy. | Cardiovasc Intervent Radiol | 2017 | https://conductscience.org/library/papers/28271328 | PubMed |
| 2 | 32757757 | Thrombectomy for Distal, Medium Vessel Occlusions: A Consensus Statement on Present Knowledge and Promising Directions. | Stroke | 2020 | https://conductscience.org/library/papers/32757757 | PubMed |
| 3 | 22053099 | A checklist for cerebral aneurysm embolization complications. | J Neurointerv Surg | 2013 | https://conductscience.org/library/papers/22053099 | PubMed |
| 4 | 29125027 | Thromboembolic complications during endovascular treatment of ruptured cerebral aneurysms. | Interv Neuroradiol | 2018 | https://conductscience.org/library/papers/29125027 | PubMed |
| 5 | 29053904 | A direct aspiration first pass technique for acute stroke therapy: a systematic review and meta-analysis. | Eur J Neurol | 2018 | https://conductscience.org/library/papers/29053904 | PubMed |
| 6 | 22932715 | Solitaire flow restoration device versus the Merci Retriever in patients with acute ischaemic stroke (SWIFT): a randomised, parallel-group, non-inferiority trial. | Lancet | 2012 | https://conductscience.org/library/papers/22932715 | PubMed |
| 7 | 16775291 | Intraprocedural thrombus formation during coil placement in ruptured intracranial aneurysms: treatment with systemic application of the glycoprotein IIb/IIIa antagonist tirofiban. | AJNR Am J Neuroradiol | 2006 | https://conductscience.org/library/papers/16775291 | PubMed |
| 8 | 31323418 | Mechanical Thrombectomy in Distal Vessels: Revascularization Rates, Complications, and Functional Outcome. | World Neurosurg | 2019 | https://conductscience.org/library/papers/31323418 | PubMed |
| 9 | 29025728 | Necessary Catheter Diameters for Mechanical Thrombectomy with ADAPT. | AJNR Am J Neuroradiol | 2017 | https://conductscience.org/library/papers/29025728 | PubMed |
| 10 | 29055224 | Primary suction thrombectomy for acute ischemic stroke: A meta-analysis of the current literature. | Clin Neurol Neurosurg | 2017 | https://conductscience.org/library/papers/29055224 | PubMed |
| 11 | 22683194 | Intra-arterial tirofiban infusion for thromboembolic complication during coil embolization of ruptured intracranial aneurysms. | Eur J Radiol | 2012 | https://conductscience.org/library/papers/22683194 | PubMed |
| 12 | 26180095 | Initial experience using the 3MAX cerebral reperfusion catheter in the endovascular treatment of acute ischemic stroke of distal arteries. | J Neurointerv Surg | 2016 | https://conductscience.org/library/papers/26180095 | PubMed |
| 13 | 30338349 | Use of microcatheters for suction thrombectomy of acute distal occlusions. | Neuroradiology | 2018 | https://conductscience.org/library/papers/30338349 | PubMed |
| 14 | 23598522 | Rescue treatment of thromboembolic complications during endovascular treatment of cerebral aneurysms. | Stroke | 2013 | https://conductscience.org/library/papers/23598522 | PubMed |
| 15 | 33360517 | Comparison Between Three Commonly Used Large-Bore Aspiration Catheters in Terms of Successful Recanalization and First-Passage Effect. | J Stroke Cerebrovasc Dis | 2021 | https://conductscience.org/library/papers/33360517 | PubMed |
| 16 | 27856436 | Diffusion-Weighted Imaging-Detected Ischemic Lesions following Endovascular Treatment of Cerebral Aneurysms: A Systematic Review and Meta-Analysis. | AJNR Am J Neuroradiol | 2017 | https://conductscience.org/library/papers/27856436 | PubMed |
| 17 | 12008697 | Postprocedure ischemic events after treatment of intracranial aneurysms with Guglielmi detachable coils. | J Neurosurg | 2002 | https://conductscience.org/library/papers/12008697 | PubMed |
| 18 | 10834641 | Prevention and treatment of thromboembolic and ischemic complications associated with endovascular procedures: Part II--Clinical aspects and recommendations. | Neurosurgery | 2000 | https://conductscience.org/library/papers/10834641 | PubMed |
| 19 | 16908567 | Procedural complications of coiling of ruptured intracranial aneurysms: incidence and risk factors in a consecutive series of 681 patients. | AJNR Am J Neuroradiol | 2006 | https://conductscience.org/library/papers/16908567 | PubMed |
| 20 | 28316869 | Forced Arterial Suction Thrombectomy Using Distal Access Catheter in Acute Ischemic Stroke. | Neurointervention | 2017 | https://conductscience.org/library/papers/28316869 | PubMed |
Cited by2
The papers in our copy of PubMed whose reference list names this one, newest first. iCite, which reads more sources, counts 2 citations.
| PMID | Title | Journal | Year | In Papers | Source |
|---|---|---|---|---|---|
| 42974627 | Outcomes Following First-Pass Direct Aspiration Versus Stent Retriever for Endovascular Thrombectomy in Primary Medium or Distal Vessel Occlusion: An Analysis of the SVIN Registry. | Stroke Vasc Interv Neurol | 2026 | https://conductscience.org/library/papers/42974627 | PubMed |
| 38213113 | Suction thrombectomy of distal medium vessel occlusion using microcatheter during mechanical thrombectomy for acute ischemic stroke: A case series. | J Cerebrovasc Endovasc Neurosurg | 2024 | https://conductscience.org/library/papers/38213113 | PubMed |
Genes1
The genes the Gene search release ties to the paper: Swiss-Prot's references first, then PubTator's text mining.
| Gene | NCBI Gene ID | Linked by | In Genes |
|---|---|---|---|
| PLAT | 5327 | PubTator's text mining | https://conductscience.org/library/genes/5327 |
Source NCBI Gene
Data dates
The date of each source this release read.
- Trials
- 2026-11-12
- Gene search
- 2026-11-11
- Pipelines
- 2026-09-18
None in this release
- Grants
- Trials
- Comments and corrections
- Drugs
- Data
Sources 11
- ChEMBL, through Open TargetsCC BY-SA 3.0
- ClinicalTrials.govNo license stated
- HGNCCC0
- iCiteCC BY 4.0
- NCBI GenePublic domain (US government)
- NIH RePORTER's grant and paper linksPublic domain
- Open TargetsCC0 1.0
- PMC's ID filePublic domain (US government)
- PubMedNLM's terms
- PubTator 3Public domain
- UniProtCC BY 4.0
Each source's terms
- ChEMBL, through Open TargetsCC BY-SA 3.0, for the parts from ChEMBL. Read on 8 Nov 2026 at https://platform-docs.opentargets.org/licence
- ClinicalTrials.govnone stated
- HGNCCC0: https://www.genenames.org/about/license/
- iCiteCC BY 4.0
- NCBI GeneNone named for the file. NCBI says information created by or for the US government on its site is in the public domain, and asks that NLM be acknowledged: https://www.ncbi.nlm.nih.gov/home/about/policies/
- NIH RePORTER's grant and paper linksPublic domain (NIH RePORTER)
- Open TargetsCC0 1.0. Open Targets asks that users cite its latest paper: Buniello et al. 2025, Open Targets Platform: facilitating therapeutic hypotheses building in drug discovery, Nucleic Acids Research 53(D1):D1467, PMID 39657122. Read on 8 Nov 2026 at https://platform-docs.opentargets.org/licence
- PMC's ID fileNone named for the file. NCBI says information created by or for the US government on its site is in the public domain, and asks that NLM be acknowledged: https://www.ncbi.nlm.nih.gov/home/about/policies/
- PubMedNLM's terms
- PubTator 3Public domain
- UniProtCC BY 4.0. UniProt's licence file: "All databases and documents in the UniProt FTP directory may be copied and redistributed freely, without advance permission, provided that this copyright statement is reproduced with each copy." UniProt asks that users cite its latest paper: The UniProt Consortium, UniProt: the Universal Protein Knowledgebase in 2025, Nucleic Acids Research 53:D609-D617, https://doi.org/10.1093/nar/gkae1010. Read on 9 Nov 2026 at https://www.uniprot.org/help/license
ClinicalTrials.gov's data carry an international copyright outside the United States: https://clinicaltrials.gov/about-site/terms-conditions.
For software
Read this paper from software.
The record and each of its lists are JSON, twenty rows a page. No key needed for records and first pages, up to 100 calls a day. With a free key, your account gets 2,000 a day and every page.
GET https://conductscience.org/api/papers/v1/35909705
GET https://conductscience.org/api/papers/v1/35909705/references?page=2