ConductScience.org, home

Paper36928130

Corneal Biomechanics After SMILE, Femtosecond-Assisted LASIK, and Photorefractive Keratectomy: A Matched Comparison Study.

Hashemi H and 5 others. Transl Vis Sci Technol, 2023. Cited by 25 papers, by iCite.

Cite this record

ConductScience Library. Corneal Biomechanics After SMILE, Femtosecond-Assisted LASIK, and Photorefractive Keratectomy: A Matched Comparison Study. Papers, record 36928130. Release papers-2026-11-12-0.1.0, 12 Nov 2026. https://conductscience.org/library/papers/36928130

Sign in to download
Sources
11 sources
Release
papers-2026-11-12-0.1.0

Paper

PubMed's record of the paper, with iCite's citation figures. No abstract is shown.

Title
Corneal Biomechanics After SMILE, Femtosecond-Assisted LASIK, and Photorefractive Keratectomy: A Matched Comparison Study.
PubMed
Journal
Transl Vis Sci Technol
PubMed
Year
2023
PubMed
Publication types
Journal Article
PubMed
Citations, by iCite
25
iCite
Relative citation ratio, by iCite
6.93
iCite
Revised in PubMed
2023-03-28
PubMed

Authors6

The authors in the order PubMed's record lists them, with the ORCID iDs it states.

OrderAuthorForenameKindORCID iD
1Hashemi HHassan
2Roberts CJCynthia J
3Elsheikh AAhmed
4Mehravaran SShiva
5Panahi PParsa
6Asgari SSoheila

Source PubMed

Sign in to download

Topics6

NLM's MeSH indexing of the paper, its major topics first.

MeSH termMajor
Keratomileusis, Laser In SituMajor topic
Photorefractive KeratectomyMajor topic
MyopiaMajor topic
Humans
Biomechanical Phenomena
Cornea

References28

The papers the reference list in PubMed's record names, those in our copy of PubMed, in the list's order.

OrderPMIDTitleJournalYearIn PapersSource
130135552Assessment of Corneal Stromal Remodeling and Regeneration after Photorefractive Keratectomy.Sci Rep2018https://conductscience.org/library/papers/30135552PubMed
224232940Impact of chamber pressure and material properties on the deformation response of corneal models measured by dynamic ultra-high-speed Scheimpflug imaging.Arq Bras Oftalmol2013https://conductscience.org/library/papers/24232940PubMed
330123381Review of Corneal Biomechanical Properties Following LASIK and SMILE for Myopia and Myopic Astigmatism.Open Ophthalmol J2018https://conductscience.org/library/papers/30123381PubMed
430203530Comparison of corneal biomechanical changes after refractive surgery by noncontact tonometry: small-incision lenticule extraction versus flap-based refractive surgery - a systematic review.Acta Ophthalmol2019https://conductscience.org/library/papers/30203530PubMed
524862302Corneal biomechanical properties after LASIK, ReLEx flex, and ReLEx smile by Scheimpflug-based dynamic tonometry.Graefes Arch Clin Exp Ophthalmol2014https://conductscience.org/library/papers/24862302PubMed
623820227Mathematical model to compare the relative tensile strength of the cornea after PRK, LASIK, and small incision lenticule extraction.J Refract Surg2013https://conductscience.org/library/papers/23820227PubMed
727457241Corneal biomechanical changes in eyes with small incision lenticule extraction and laser assisted in situ keratomileusis.BMC Ophthalmol2016https://conductscience.org/library/papers/27457241PubMed
827505316Influence of Pachymetry and Intraocular Pressure on Dynamic Corneal Response Parameters in Healthy Patients.J Refract Surg2016https://conductscience.org/library/papers/27505316PubMed
926938343Complications of Refractive Surgery: Ectasia After Refractive Surgery.Int Ophthalmol Clin2016https://conductscience.org/library/papers/26938343PubMed
1030902432Assessment of corneal biomechanical parameters in healthy and keratoconic eyes using dynamic bidirectional applanation device and dynamic Scheimpflug analyzer.J Cataract Refract Surg2019https://conductscience.org/library/papers/30902432PubMed
1133854295Corneal Biomechanical Assessment with Ultra-High-Speed Scheimpflug Imaging During Non-Contact Tonometry: A Prospective Review.Clin Ophthalmol2021https://conductscience.org/library/papers/33854295PubMed
1234259803Comparison of Clinical and Biomechanical Outcomes of Small Incision Lenticule Extraction With 120- and 140-µm Cap Thickness.Transl Vis Sci Technol2021https://conductscience.org/library/papers/34259803PubMed
1324857440Comparison of biomechanical effects of small-incision lenticule extraction and laser in situ keratomileusis: finite-element analysis.J Cataract Refract Surg2014https://conductscience.org/library/papers/24857440PubMed
1426554611Evaluation of Changes in Human Corneas After Femtosecond Laser-Assisted LASIK and Small-Incision Lenticule Extraction (SMILE) Using Non-Contact Tonometry and Ultra-High-Speed Camera (Corvis ST).Curr Eye Res2016https://conductscience.org/library/papers/26554611PubMed
1531370817Corneal biomechanical properties after SMILE versus FLEX, LASIK, LASEK, or PRK: a systematic review and meta-analysis.BMC Ophthalmol2019https://conductscience.org/library/papers/31370817PubMed
1616720023Biomechanics and wound healing in the cornea.Exp Eye Res2006https://conductscience.org/library/papers/16720023PubMed
1732398416Risk factors for postlaser refractive surgery corneal ectasia.Curr Opin Ophthalmol2020https://conductscience.org/library/papers/32398416PubMed
1824726160Changes in custom biomechanical variables after femtosecond laser in situ keratomileusis and photorefractive keratectomy for myopia.J Cataract Refract Surg2014https://conductscience.org/library/papers/24726160PubMed
1935156458Predictability of Central Corneal Stromal Reduction After SMILE and FS-LASIK for High Myopia Correction: A Prospective Randomized Contralateral Eye Study.J Refract Surg2022https://conductscience.org/library/papers/35156458PubMed
2019574911Comparison of the changes in corneal biomechanical properties after photorefractive keratectomy and laser in situ keratomileusis.Cornea2009https://conductscience.org/library/papers/19574911PubMed

See all 28 referencesSign in to download

Cited by14

The papers in our copy of PubMed whose reference list names this one, newest first. iCite, which reads more sources, counts 25 citations.

PMIDTitleJournalYearIn PapersSource
42739591Safety and Efficacy of Keratorefractive Lenticule Extraction (KLEx) for High Myopia with the CLEAR Platform.J Clin Med2026https://conductscience.org/library/papers/42739591PubMed
42638086Incremental contribution of Corvis ST dynamic biomechanical parameters to interpretable machine learning prediction of clinician-selected refractive procedures: a retrospective observational study.BMC Ophthalmol2026https://conductscience.org/library/papers/42638086PubMed
42549095Femtosecond laser-assisted LASIK in the SMILE era: a mini review of patient-centered procedure selection.Front Med (Lausanne)2026https://conductscience.org/library/papers/42549095PubMed
42181685Artificial intelligence in refractive surgery: progress, challenges, and future directions.Front Cell Dev Biol2026https://conductscience.org/library/papers/42181685PubMed
41658982Comparison of correction formulas for intraocular pressure measured by Goldmann tonometer following various refractive surgeries (FS-LASIK, SMILE, tPRK).Front Bioeng Biotechnol2026https://conductscience.org/library/papers/41658982PubMed
41384799Anterior Segment OCT Thickness Difference Maps for Monitoring Corneal Thickness Changes: Small-Incision Lenticule Extraction as a Model.Transl Vis Sci Technol2025https://conductscience.org/library/papers/41384799PubMed
41325313A 6-month longitudinal and comparative study of corneal biomechanical properties after SMILE with two different optical zone sizes.PLoS One2025https://conductscience.org/library/papers/41325313PubMed
41301155The Impact of Small Incision Lenticule Extraction on the Biomechanical Properties of the Cornea: A Review.Bioengineering (Basel)2025https://conductscience.org/library/papers/41301155PubMed
41099592Long-Term Corneal Reshaping Using Riboflavin-UVA Crosslinking Combined With Decorin in Rabbits.Transl Vis Sci Technol2025https://conductscience.org/library/papers/41099592PubMed
40855539Corneal biomechanics and tomographic parameters for different corneal diameters in Chinese patients with myopia.BMC Ophthalmol2025https://conductscience.org/library/papers/40855539PubMed
40035722Evaluation of the Long-Term Corneal Biomechanics Following SMILE With Different Residual Stromal Bed Thickness in Rabbits.Transl Vis Sci Technol2025https://conductscience.org/library/papers/40035722PubMed
39470468The Increase in Corneal Stiffness After Accelerated Corneal Cross-Linking in Progressive Keratoconus Using Different Methods of Epithelial Debridement.Transl Vis Sci Technol2024https://conductscience.org/library/papers/39470468PubMed
38954134Early elastic and viscoelastic corneal biomechanical changes after photorefractive keratectomy and small incision lenticule extraction.Int Ophthalmol2024https://conductscience.org/library/papers/38954134PubMed
38089509Femtosecond laser applications in corneal surgery.Taiwan J Ophthalmol2023https://conductscience.org/library/papers/38089509PubMed

Sign in to download

Genes1

The genes the Gene search release ties to the paper: Swiss-Prot's references first, then PubTator's text mining.

GeneNCBI Gene IDLinked byIn Genes
SFTPA1653509PubTator's text mininghttps://conductscience.org/library/genes/653509

Source NCBI Gene

Sign in to download

Data dates

The date of each source this release read.

PubMed
2026-11-06
PubMed
iCite
2026-11-05
iCite
PMC's ID file
2026-11-05
PMC's ID file
NIH RePORTER's grant and paper links
2026-11-01
NIH RePORTER's grant and paper links
Trials
2026-11-12
Gene search
2026-11-11
Pipelines
2026-09-18

None in this release

  • Grants
  • Trials
  • Comments and corrections
  • Drugs
  • Data

Sources 11

  • ChEMBL, through Open TargetsCC BY-SA 3.0
  • ClinicalTrials.govNo license stated
  • HGNCCC0
  • iCiteCC BY 4.0
  • NCBI GenePublic domain (US government)
  • NIH RePORTER's grant and paper linksPublic domain
  • Open TargetsCC0 1.0
  • PMC's ID filePublic domain (US government)
  • PubMedNLM's terms
  • PubTator 3Public domain
  • UniProtCC BY 4.0
Each source's terms
  • ChEMBL, through Open TargetsCC BY-SA 3.0, for the parts from ChEMBL. Read on 8 Nov 2026 at https://platform-docs.opentargets.org/licence
  • ClinicalTrials.govnone stated
  • HGNCCC0: https://www.genenames.org/about/license/
  • iCiteCC BY 4.0
  • NCBI GeneNone named for the file. NCBI says information created by or for the US government on its site is in the public domain, and asks that NLM be acknowledged: https://www.ncbi.nlm.nih.gov/home/about/policies/
  • NIH RePORTER's grant and paper linksPublic domain (NIH RePORTER)
  • Open TargetsCC0 1.0. Open Targets asks that users cite its latest paper: Buniello et al. 2025, Open Targets Platform: facilitating therapeutic hypotheses building in drug discovery, Nucleic Acids Research 53(D1):D1467, PMID 39657122. Read on 8 Nov 2026 at https://platform-docs.opentargets.org/licence
  • PMC's ID fileNone named for the file. NCBI says information created by or for the US government on its site is in the public domain, and asks that NLM be acknowledged: https://www.ncbi.nlm.nih.gov/home/about/policies/
  • PubMedNLM's terms
  • PubTator 3Public domain
  • UniProtCC BY 4.0. UniProt's licence file: "All databases and documents in the UniProt FTP directory may be copied and redistributed freely, without advance permission, provided that this copyright statement is reproduced with each copy." UniProt asks that users cite its latest paper: The UniProt Consortium, UniProt: the Universal Protein Knowledgebase in 2025, Nucleic Acids Research 53:D609-D617, https://doi.org/10.1093/nar/gkae1010. Read on 9 Nov 2026 at https://www.uniprot.org/help/license

ClinicalTrials.gov's data carry an international copyright outside the United States: https://clinicaltrials.gov/about-site/terms-conditions.

For software

Read this paper from software.

The record and each of its lists are JSON, twenty rows a page. No key needed for records and first pages, up to 100 calls a day. With a free key, your account gets 2,000 a day and every page.

GET https://conductscience.org/api/papers/v1/36928130

GET https://conductscience.org/api/papers/v1/36928130/references?page=2