ConductScience.org, home

Trial · NCT01446965

Vest Prevention of Early Sudden Death Trial and VEST Registry

NCT01446965, Not applicable, Completed, University of California, San Francisco; results first posted 2021-01-20

3 sourcestrials-2026-11-12-0.5.0

Download JSON
Cite this record

ConductScience Library. Vest Prevention of Early Sudden Death Trial and VEST Registry. Trials, record NCT01446965. Release trials-2026-11-12-0.5.0, 12 Nov 2026. https://conductscience.org/library/trials/NCT01446965

On this page

Trial

As registered on ClinicalTrials.gov, in the graph's capture of the registry.

Title
Vest Prevention of Early Sudden Death Trial and VEST Registry
NCT number
NCT01446965
Status
Completed
Phases
Not applicable
Enrollment
2,348 participants, actual
Lead sponsor
University of California, San Francisco
Conditions
Myocardial Infarction, Ventricular Dysfunction, Sudden Death, Ventricular Tachycardia, Ventricular Fibrillation
Interventions
wearable defibrillator
First posted
2011-10-05
Last updated
2021-01-20
Results first posted
2021-01-20

Source ClinicalTrials.gov

Registered outcomes3

Each outcome the trial registered, primary first, in ClinicalTrials.gov's words.

ListOutcomeTime frameDescription
PrimarySudden Death Mortalitythree months after myocardial infarction
For witnessed deaths, sudden cardiac death will be defined as an unexpected non-traumatic, non-self-inflicted fatality in otherwise stable participants who die within one hour of the onset of the terminal symptoms. For unwitnessed deaths, participants will meet the definition of sudden death if they are found dead within 24 hours of being well, assuming there is no evidence of another cause of death during that time period.
SecondaryAll Cause Mortalitythree months after myocardial infarctionAll deaths, due to any cause
SecondaryCompliance With Wearable Defibrillator Usethree months after myocardial infarctiondaily wear time of the device

Outcomes3

Each outcome the trial posted results for, in ClinicalTrials.gov's words.

TypeOutcomeTime framePopulationUnitsMeasured as
PRIMARYSudden Death Mortalitythree months after myocardial infarctionA total of 2302 participants were included in the analyses.ParticipantsCOUNT_OF_PARTICIPANTS
SECONDARYAll Cause Mortalitythree months after myocardial infarctionParticipantsCOUNT_OF_PARTICIPANTS
SECONDARYCompliance With Wearable Defibrillator Usethree months after myocardial infarctionConventional treatment participants did not wear defibrillator.hours per dayMEDIAN

Results by group5

Each measurement the trial posted, group by group, in the words and numbers it posted.

OutcomeGroupCategoryValueSpreadUnits
Sudden Death MortalityWearable Defibrillator25Participants
Sudden Death MortalityConventional Treatment19Participants
All Cause MortalityWearable Defibrillator48Participants
All Cause MortalityConventional Treatment38Participants
Compliance With Wearable Defibrillator UseWearable Defibrillator18Inter-Quartile Range 3.8 to 22.7hours per day

Participant flow20

How many started, completed or left each group, period by period.

PeriodMilestoneGroupParticipantsUnits counted
RandominizationSTARTEDWearable Defibrillator1,554
RandominizationSTARTEDConventional Treatment794
RandominizationCOMPLETEDWearable Defibrillator1,524
RandominizationCOMPLETEDConventional Treatment778
RandominizationNOT COMPLETEDWearable Defibrillator30
RandominizationNOT COMPLETEDConventional Treatment16
Participants Followed and AnalyzedSTARTEDWearable Defibrillator1,524
Participants Followed and AnalyzedSTARTEDConventional Treatment778
Participants Followed and AnalyzedReceived WCDWearable Defibrillator1,481
Participants Followed and AnalyzedReceived WCDConventional Treatment0

Adverse events30

Each adverse event the trial posted, group by group: the participants affected out of those at risk.

TypeEventOrgan systemGroupAffectedAt riskEvents
otherFatigueGeneral disordersWearable Defibrillator5101,524
otherFatigueGeneral disordersConventional Treatment274778
otherBack painMusculoskeletal and connective tissue disordersWearable Defibrillator2831,524
otherBack painMusculoskeletal and connective tissue disordersConventional Treatment137778
otherTrouble sleepingGeneral disordersWearable Defibrillator5511,524
otherTrouble sleepingGeneral disordersConventional Treatment264778
otherDizzinessGeneral disordersWearable Defibrillator3441,524
otherDizzinessGeneral disordersConventional Treatment166778
otherFaintingGeneral disordersWearable Defibrillator591,524
otherFaintingGeneral disordersConventional Treatment36778

Adverse event totals6

The totals the trial posted for each group.

TotalGroupAffectedAt risk
Total, all-cause mortalityWearable Defibrillator481,524
Total, all-cause mortalityConventional Treatment38778
Total, other adverse eventsWearable Defibrillator1,4211,524
Total, other adverse eventsConventional Treatment714778
Total, serious adverse eventsWearable Defibrillator4751,524
Total, serious adverse eventsConventional Treatment253778

Papers1

The papers the trial lists on ClinicalTrials.gov.

PMIDListed as
30280654RESULT

Source PubMed

Grants0

The grants NIH RePORTER links to the trial, newest funded first: NIH's, and some of AHRQ's, CDC's, FDA's and VA's. Each shows its title, principal investigators, organization and funder in its newest year.

None in this release.

Trial comparisons4

Comparisons of the trial's two groups, calculated by ConductScience from the counts it posted.

ComparisonSource
Wearable Defibrillator vs Conventional Treatment: Sudden Death MortalityTrial comparisons
Wearable Defibrillator vs Conventional Treatment: All Cause MortalityTrial comparisons
Wearable Defibrillator vs Conventional Treatment: deaths from any causeTrial comparisons
Wearable Defibrillator vs Conventional Treatment: serious adverse eventsTrial comparisons

Tests0

The ConductCognition tests this trial's registered outcomes name, as ScienceGraph matched them in trial-tests-2026-11-12-0.2.1.

None in this release.

Data dates

The day each source was copied for this release.

ClinicalTrials.gov
2026-11-12
ClinicalTrials.gov
Results, from AACT
2026-03-23
AACT
NIH grant links
2026-11-13
NIH RePORTER

Sources 3

  • ClinicalTrials.gov's posted results, through CTTI's AACTFreely available. Acknowledgement requested
  • ClinicalTrials.govNo license stated
  • NIH RePORTER's clinical studies and project filesPublic domain
Each source's terms
  • ClinicalTrials.gov's posted results, through CTTI's AACTClinicalTrials.gov data via Aggregate Analysis of ClinicalTrials.gov (AACT), CTTI. CTTI makes its materials freely available and requests acknowledgement. https://aact.ctti-clinicaltrials.org/documentation/299
  • ClinicalTrials.govnone stated
  • NIH RePORTER's clinical studies and project filesPublic domain (NIH RePORTER)

ClinicalTrials.gov's data carry an international copyright outside the United States: https://clinicaltrials.gov/about-site/terms-conditions.

For software

Read this trial from software.

The record and each of its lists are JSON, twenty rows a page. No key.

GET https://conductscience.org/api/trials/v1/NCT01446965

GET https://conductscience.org/api/trials/v1/NCT01446965/events?page=2