Paper32709239
Kinematics and temporospatial parameters during gait from inertial motion capture in adults with and without HIV: a validity and reliability study.
Berner K and 2 others. Biomed Eng Online, 2020. Cited by 17 papers, by iCite.
Cite this record
ConductScience Library. Kinematics and temporospatial parameters during gait from inertial motion capture in adults with and without HIV: a validity and reliability study. Papers, record 32709239. Release papers-2026-11-12-0.1.0, 12 Nov 2026. https://conductscience.org/library/papers/32709239
- Sources
- 11 sources
- Release
- papers-2026-11-12-0.1.0
Paper
PubMed's record of the paper, with iCite's citation figures. No abstract is shown.
- Title
- Kinematics and temporospatial parameters during gait from inertial motion capture in adults with and without HIV: a validity and reliability study.
- PubMed
Topics9
NLM's MeSH indexing of the paper, its major topics first.
| MeSH term | Major |
|---|---|
| Gait Analysis | Major topic |
| HIV Infections | Major topic |
| Mechanical Phenomena | Major topic |
| Spatio-Temporal Analysis | Major topic |
| Adult | |
| Biomechanical Phenomena | |
| Female | |
| Humans | |
| Male |
Source PubMed
Grants4
Each grant PubMed's record writes, matched to the NIH project NIH's grant and paper links name for this paper, and each of those links the record does not write.
| Grant, as the record writes it | Agency | Country | NIH project | Stated by |
|---|---|---|---|---|
| National Health Scholars Programme | South African Medical Research Council | PubMed | ||
| Self-Initiated Research Grant | South African Medical Research Council | PubMed | ||
| SU-PT-16/10- 000057 | Harry Crossley Foundation | PubMed | ||
| SU-PT-15/10-000005 | Harry Crossley Foundation | PubMed |
Source PubMed
References43
The papers the reference list in PubMed's record names, those in our copy of PubMed, in the list's order.
| Order | PMID | Title | Journal | Year | In Papers | Source |
|---|---|---|---|---|---|---|
| 1 | 23143526 | Risk factors for falls in HIV-infected persons. | J Acquir Immune Defic Syndr | 2012 | https://conductscience.org/library/papers/23143526 | PubMed |
| 2 | 30583508 | Towards Inertial Sensor Based Mobile Gait Analysis: Event-Detection and Spatio-Temporal Parameters. | Sensors (Basel) | 2018 | https://conductscience.org/library/papers/30583508 | PubMed |
| 3 | 16980142 | When to use agreement versus reliability measures. | J Clin Epidemiol | 2006 | https://conductscience.org/library/papers/16980142 | PubMed |
| 4 | 31660363 | Fall History and Associated Factors Among Adults Living With HIV-1 in the Cape Winelands, South Africa: An Exploratory Investigation. | Open Forum Infect Dis | 2019 | https://conductscience.org/library/papers/31660363 | PubMed |
| 5 | 30613081 | Evaluation of Validity and Reliability of Inertial Measurement Unit-Based Gait Analysis Systems. | Ann Rehabil Med | 2018 | https://conductscience.org/library/papers/30613081 | PubMed |
| 6 | 20457954 | Continued high prevalence and adverse clinical impact of human immunodeficiency virus-associated sensory neuropathy in the era of combination antiretroviral therapy: the CHARTER Study. | Arch Neurol | 2010 | https://conductscience.org/library/papers/20457954 | PubMed |
| 7 | 19911215 | First in vivo assessment of "Outwalk": a novel protocol for clinical gait analysis based on inertial and magnetic sensors. | Med Biol Eng Comput | 2010 | https://conductscience.org/library/papers/19911215 | PubMed |
| 8 | 28433867 | Validity and repeatability of inertial measurement units for measuring gait parameters. | Gait Posture | 2017 | https://conductscience.org/library/papers/28433867 | PubMed |
| 9 | 26790409 | Validity and reliability of a portable gait analysis system for measuring spatiotemporal gait characteristics: comparison to an instrumented treadmill. | J Neuroeng Rehabil | 2016 | https://conductscience.org/library/papers/26790409 | PubMed |
| 10 | 28113185 | Toward Pervasive Gait Analysis With Wearable Sensors: A Systematic Review. | IEEE J Biomed Health Inform | 2016 | https://conductscience.org/library/papers/28113185 | PubMed |
| 11 | 28366438 | Measuring joint kinematics of treadmill walking and running: Comparison between an inertial sensor based system and a camera-based system. | J Biomech | 2017 | https://conductscience.org/library/papers/28366438 | PubMed |
| 12 | 9225846 | Use of the standard error as a reliability index of interest: an applied example using elbow flexor strength data. | Phys Ther | 1997 | https://conductscience.org/library/papers/9225846 | PubMed |
| 13 | 24434881 | Recommendations for standardizing validation procedures assessing physical activity of older persons by monitoring body postures and movements. | Sensors (Basel) | 2014 | https://conductscience.org/library/papers/24434881 | PubMed |
| 14 | 24798823 | Minimal clinically important difference for change in comfortable gait speed of adults with pathology: a systematic review. | J Eval Clin Pract | 2014 | https://conductscience.org/library/papers/24798823 | PubMed |
| 15 | 28657587 | Towards Mobile Gait Analysis: Concurrent Validity and Test-Retest Reliability of an Inertial Measurement System for the Assessment of Spatio-Temporal Gait Parameters. | Sensors (Basel) | 2017 | https://conductscience.org/library/papers/28657587 | PubMed |
| 16 | 31470423 | Validity of Mobility Lab (version 2) for gait assessment in young adults, older adults and Parkinson's disease. | Physiol Meas | 2019 | https://conductscience.org/library/papers/31470423 | PubMed |
| 17 | 18502130 | Joint kinematics estimate using wearable inertial and magnetic sensing modules. | Gait Posture | 2008 | https://conductscience.org/library/papers/18502130 | PubMed |
| 18 | 30935116 | Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review. | Sensors (Basel) | 2019 | https://conductscience.org/library/papers/30935116 | PubMed |
| 19 | 29028626 | Accuracy of three methods in gait event detection during overground running. | Gait Posture | 2018 | https://conductscience.org/library/papers/29028626 | PubMed |
| 20 | 10907753 | Measures of reliability in sports medicine and science. | Sports Med | 2000 | https://conductscience.org/library/papers/10907753 | PubMed |
Cited by10
The papers in our copy of PubMed whose reference list names this one, newest first. iCite, which reads more sources, counts 17 citations.
| PMID | Title | Journal | Year | In Papers | Source |
|---|---|---|---|---|---|
| 40692809 | Novel magnetometer-free inertial-measurement-unit-based orientation estimation approach for measuring upper limb kinematics. | Wearable Technol | 2025 | https://conductscience.org/library/papers/40692809 | PubMed |
| 39795564 | Validity of Wearable Inertial Sensors for Gait Analysis: A Systematic Review. | Diagnostics (Basel) | 2024 | https://conductscience.org/library/papers/39795564 | PubMed |
| 39659378 | Dynamic Alignment Changes of the Spine, Pelvis, and Lower Limbs during Gait Analyzed Using Inertial Motion Capture in Patients with Adult Spinal Deformity. | Spine Surg Relat Res | 2024 | https://conductscience.org/library/papers/39659378 | PubMed |
| 39275706 | A Novel Method and System Implementation for Precise Estimation of Single-Axis Rotational Angles. | Sensors (Basel) | 2024 | https://conductscience.org/library/papers/39275706 | PubMed |
| 37656410 | Daily walking kinematic characteristics of the elderly in different residential settings: experimental study on Chinese community-living elderly and long-term nursing home residents. | Aging Clin Exp Res | 2023 | https://conductscience.org/library/papers/37656410 | PubMed |
| 36831922 | Changes in Coordination and Its Variability with an Increase in Functional Performance of the Lower Extremities. | Biosensors (Basel) | 2023 | https://conductscience.org/library/papers/36831922 | PubMed |
| 35997418 | Robot-Assisted Ankle Rehabilitation Using the Hybrid Assistive Limb for Children after Equinus Surgery: A Report of Two Cases. | Pediatr Rep | 2022 | https://conductscience.org/library/papers/35997418 | PubMed |
| 35481275 | The Effect of Inclines on Joint Angles in Stroke Survivors During Treadmill Walking. | Front Neurol | 2022 | https://conductscience.org/library/papers/35481275 | PubMed |
| 34557560 | Mobility Deviations in Adults With Human Immunodeficiency Virus: A Cross-Sectional Assessment Using Gait Analysis, Functional Performance, and Self-Report. | Open Forum Infect Dis | 2021 | https://conductscience.org/library/papers/34557560 | PubMed |
| 34073881 | Detection of Movement Events of Long-Track Speed Skating Using Wearable Inertial Sensors. | Sensors (Basel) | 2021 | https://conductscience.org/library/papers/34073881 | PubMed |
Genes2
The genes the Gene search release ties to the paper: Swiss-Prot's references first, then PubTator's text mining.
| Gene | NCBI Gene ID | Linked by | In Genes | Source |
|---|---|---|---|---|
| CD4 | 920 | PubTator's text mining | https://conductscience.org/library/genes/920 | NCBI Gene |
| IL6 | 3569 | PubTator's text mining | https://conductscience.org/library/genes/3569 | NCBI Gene |
Data dates
The date of each source this release read.
- Trials
- 2026-11-12
- Gene search
- 2026-11-11
- Pipelines
- 2026-09-18
None in this release
- Trials
- Comments and corrections
- Drugs
- Data
Sources 11
- ChEMBL, through Open TargetsCC BY-SA 3.0
- ClinicalTrials.govNo license stated
- HGNCCC0
- iCiteCC BY 4.0
- NCBI GenePublic domain (US government)
- NIH RePORTER's grant and paper linksPublic domain
- Open TargetsCC0 1.0
- PMC's ID filePublic domain (US government)
- PubMedNLM's terms
- PubTator 3Public domain
- UniProtCC BY 4.0
Each source's terms
- ChEMBL, through Open TargetsCC BY-SA 3.0, for the parts from ChEMBL. Read on 8 Nov 2026 at https://platform-docs.opentargets.org/licence
- ClinicalTrials.govnone stated
- HGNCCC0: https://www.genenames.org/about/license/
- iCiteCC BY 4.0
- NCBI GeneNone named for the file. NCBI says information created by or for the US government on its site is in the public domain, and asks that NLM be acknowledged: https://www.ncbi.nlm.nih.gov/home/about/policies/
- NIH RePORTER's grant and paper linksPublic domain (NIH RePORTER)
- Open TargetsCC0 1.0. Open Targets asks that users cite its latest paper: Buniello et al. 2025, Open Targets Platform: facilitating therapeutic hypotheses building in drug discovery, Nucleic Acids Research 53(D1):D1467, PMID 39657122. Read on 8 Nov 2026 at https://platform-docs.opentargets.org/licence
- PMC's ID fileNone named for the file. NCBI says information created by or for the US government on its site is in the public domain, and asks that NLM be acknowledged: https://www.ncbi.nlm.nih.gov/home/about/policies/
- PubMedNLM's terms
- PubTator 3Public domain
- UniProtCC BY 4.0. UniProt's licence file: "All databases and documents in the UniProt FTP directory may be copied and redistributed freely, without advance permission, provided that this copyright statement is reproduced with each copy." UniProt asks that users cite its latest paper: The UniProt Consortium, UniProt: the Universal Protein Knowledgebase in 2025, Nucleic Acids Research 53:D609-D617, https://doi.org/10.1093/nar/gkae1010. Read on 9 Nov 2026 at https://www.uniprot.org/help/license
ClinicalTrials.gov's data carry an international copyright outside the United States: https://clinicaltrials.gov/about-site/terms-conditions.
For software
Read this paper from software.
The record and each of its lists are JSON, twenty rows a page. No key.
GET https://conductscience.org/api/papers/v1/32709239
GET https://conductscience.org/api/papers/v1/32709239/references?page=2